Product image is representative; revision or series may vary. Contact us to request a specific version.
Product Describe:
Bently Nevada 990-08-XX-01-00 MOD:165353-01 is a loop-powered 990 vibration transmitter that converts a compatible NSv proximity input to a proportional 4 to 20 mA signal. It retains the supplied XX and MOD identity for controlled matching.
Bently Nevada 990-08-XX-01-00 MOD:165353-01 is a loop-powered 990 vibration transmitter that converts a compatible NSv proximity input to a proportional 4 to 20 mA signal. It retains the supplied XX and MOD identity for controlled matching.
Two-wire loop-powered transmitter
Proportional 4 to 20 mA output
Dynamic PROX OUT connection
DIN-rail mounting option
Apply 990-08-XX-01-00 MOD:165353-01 to the documented NSv probe loop and plant control input with the approved loop-power and scaling arrangement.
Important Notice: Confirm 990-08-XX-01-00 MOD:165353-01, its XX and MOD identity, NSv input, loop power, scaling and mounting before release.
The first document presents model-specific technical and system data. The second provides a separate installation, connection, commissioning and acceptance workflow.
Machine vibration trending
Provides a proportional vibration signal to a control or monitoring system.
Compact protection loops
Uses an integrated NSv Proximitor interface in a field transmitter.
Dynamic diagnostics
Provides a buffered dynamic signal for controlled diagnostic use.
Legacy loop replacement
Preserves the documented 990 range, mounting and custom identity.
Read the applicable Bently Nevada instructions before work. Verify Bently Nevada 990-08-XX-01-00 MOD:165353-01 and the installed system configuration before commissioning.
1
Verify the complete 990-08-XX-01-00 MOD:165353-01 marking.
2
Resolve the XX block from the physical nameplate.
3
Retain MOD 165353-01 without interpretation.
4
Use only a compatible NSv probe system.
5
Confirm loop polarity before energizing.
6
Set zero and span only with the approved procedure.
7
Check PROX OUT and COM wiring before diagnostics.
8
Verify 4 to 20 mA scaling and signal-defeat behavior before release.
Technical notes
Publication 141612 defines the 990 family, 0 to 8 mil peak-to-peak range, DIN mounting and no-approval options but does not decode XX or MOD 165353-01. Preserve the full nameplate and verify the installed NSv probe chain before substitution.