Speak to a sourcing specialist
sales13@apterpower.com

125720-01

Four-Channel Relay Output Module
In Stock
Ships by Monday, November 2
Fast Shipping Available
Bently Nevada 125720-01
Bently Nevada 125720-01
Bently Nevada 125720-01
Bently Nevada 125720-01
Bently Nevada 125720-01
Bently Nevada 125720-01
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Bently Nevada 125720-01 is a Four-Channel Relay Output Module. It exposes four programmable SPDT contacts for machinery alarm and shutdown logic.
Get a quick price for 125720-01
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 125720-01

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    125720-01
  • Estimated shipping dimensions:
    2.5x24.1x10.2 cm
  • Weight:
    0.4 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Relay outputs:
    4
  • Relay contact type:
    SPDT
  • Relay sealing:
    Epoxy-sealed
  • Arc suppressor:
    250 Vrms standard
  • Contact life:
    100000 cycles at 5 A, 24 Vdc or 240 Vac
  • Coil operating mode:
    Normally energized or de-energized
  • Minimum switched current:
    100 mA at 12 Vdc
  • Maximum switched current:
    2 A at 0-30 Vdc
  • Maximum DC switched voltage:
    125 Vdc
  • Maximum AC switched voltage:
    250 Vac
  • Maximum AC switched power:
    450 VA
  • Operating temperature:
    -30 to +65 degC
  • Storage temperature:
    -40 to +85 degC
  • Humidity:
    95% non-condensing
  • Rear rack space:
    1 full-height slot
  • Service status:
    Repair-only spare

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 125720-01 is the four-channel relay output module used with a 3500/32M relay control module. It exposes four programmable SPDT contacts for machinery alarm and shutdown logic.
  • Provides four independent SPDT relay-output channels
  • Receives programmed alarm-drive logic from the 3500/32M control module
  • Supports normally energized or normally de-energized operation per relay
  • Switches external annunciation, trip and interlock circuits within documented contact ratings

125720-01 installs with 3500 rack rear slot, 3500/32M relay control module, Alarm-drive logic configuration, Protected external trip or annunciation circuits in an engineered 3500/32M Relay System configuration.

The commissioning workflow covers installed-hardware matching, controlled start-up and functional verification for this four-channel relay output module.

Important Notice: Confirm the complete 125720-01 marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power 125720-01 Manuals and Guides
Apter Power 125720-01 Product Technical Reference PDFBently Nevada 125720-01 Official Manual PDF
The first document is an Apter Power model-specific technical reference. The second supports model-specific installation, configuration and engineering verification.
Machinery shutdown relay logicProvides four independent SPDT relay-output channels
Alert and Danger annunciationReceives programmed alarm-drive logic from the 3500/32M control module
Not-OK interlock outputSupports normally energized or normally de-energized operation per relay
Multi-channel voting alarm outputSwitches external annunciation, trip and interlock circuits within documented contact ratings
Read the applicable Bently Nevada installation instructions before work. Verify 125720-01 and the installed 3500/32M Relay System configuration.
1Confirm 125720-01 is assigned to the rear slot paired with the intended 3500/32M control module.
2Isolate every AC and DC field source before touching the relay terminals.
3Record common, normally open and normally closed conductors for all four SPDT channels.
4Verify the normally energized or de-energized selection for each relay before power-up.
5Keep switched voltage and current within the published standard-system ratings.
6Use the restricted ratings when the rack is approved for hazardous-area or functional-safety service.
7Recreate the documented Alarm Drive AND/OR logic in Rack Configuration Software.
8Test Alert, Danger, Not-OK and selected PPL inputs without bypassing plant safeguards.

Technical notes

Review each contact load and relay energization philosophy, isolate every external source at the terminals and prove the configured AND/OR voting logic before reconnecting shutdown circuits.

FAQ View All FAQ

  • How should 125720-01 be isolated before field wiring is disturbed?
    Place the protected machine in its approved maintenance state, isolate rack and field energy applicable to Alarm-drive logic configuration, and prove the terminals safe before disconnection.
  • Which configuration should be restored after replacing 125720-01?
    Restore the approved 3500/32M Relay System slot, channel or interface configuration and verify that every connected circuit retains its original assignment.
  • How can 125720-01 be commissioned for machinery shutdown relay logic?
    Apply a controlled input or command, review the model-specific diagnostics and prove the expected measurement, indication and protection response before releasing the channel.
  • What technical value deserves special attention when checking 125720-01?
    Verify the published relay sealing value of Epoxy-sealed against the installed configuration and test record.
  • Can 125720-01 be exchanged with another 3500 I/O or monitor execution?
    Only when the complete part number, termination style, transducer or interface type and approved rack configuration match the installed duty; do not transfer settings from an adjacent model.
  • What evidence should be retained after 125720-01 returns to service?
    Retain the full 125720-01 identity, as-left connections, restored configuration, final diagnostics and the controlled functional-test result for alert and danger annunciation.
  • Which rack hardware must be matched before installing 125720-01?
    Match 125720-01 to the documented 3500 rack rear slot and 3500/32M relay control module; confirm the front/rear slot pairing and the complete physical marking before connection.
  • What as-found information should an engineer record before removing 125720-01?
    Record every channel or port assignment, connector identity, configured function, cable tag and diagnostic state associated with 125720-01.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.