Match the complete marking
Include 86691-01250-0400-15 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 86691-01250-0400-15 reference with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 86691-01250-0400-15
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:86691-01250-0400-15
-
Weight:0.2 kg
-
Tariff Code:8537101190
-
Product type:Legacy custom vibration/proximity probe
-
Documented family:7200 series
-
Documented application:Axial displacement measurement
-
Measurement principle:Eddy-current non-contact sensing
-
Electrical role:Passive probe in a matched transducer chain
-
Standalone voltage output:None
-
Required companion components:Documented cable and 7200 signal conditioner
-
Target requirement:Conductive target characterized for the installed channel
-
Mechanical datum:Installed probe tag, reach and lock position must be retained
-
Compatibility boundary:Custom option fields are not decoded with standard 3300 tables
-
Family reference cable:95-ohm coaxial in standard 7200 5/8 mm systems
-
Family reference frequency:0 to 10 kHz for standard matched 7200 5/8 mm systems
-
Evidence boundary:Exact custom electrical and dimensional ratings require the installation drawing
Information
- The complete 86691-01250-0400-15 code is installation-specific; preserve the probe tag, service location, mechanical datum and matching 7200 cable/conditioner record.
Axial-position datum: Rotor position, thrust clearance and probe reach must be documented before disturbance.
Evidence boundary: Exact custom ratings remain tied to the installation drawing and channel calibration record.
Replacement begins by recording rotor position, thrust-bearing clearances, probe reach, lock position, target geometry and cable routing. Keep the sensing face and coaxial interfaces clean, dry and supported, and preserve the original electrical-length relationship.
The probe has no standalone voltage output; response is created by the matched cable and 7200 signal conditioner. Commissioning should restore the documented gap, compare static output and monitor indication with the accepted baseline, and prove the complete axial channel through the approved machine procedure.
-
Bently Nevada 86691-01250-0400-15 technical reference
Apter Power reference with verified manufacturer data and exact-model applicability. -
Bently Nevada 86691-01250-0400-15 engineering guide
Apter Power installation, configuration, diagnostic and acceptance guidance.
Platform applications: The uses below depend on the installed controller configuration and approved system design.
-
Radial shaft vibration
Use a documented bearing location and matched transducer chain to observe shaft motion relative to the probe mounting. -
Axial position
Orient the probe toward an approved conductive thrust target and keep expected travel inside the characterized working region. -
Phase or speed reference
Use only where the installed target feature and monitoring channel are approved for once-per-turn reference measurement. -
Legacy-channel maintenance
Preserve the exact mechanical identity, cable construction, system length and companion electronics recorded for the installed channel.
Match every field of 86691-01250-0400-15 with the installed record before removal or installation.
Keep the tip, connector and cable free from impact, moisture, metal chips and unsupported loading.
Record reach, thread engagement, locknut position and target relationship before disturbing the installed component.
Maintain the approved bend radius, separation and strain relief; do not twist or crush the coaxial path.
Use the approved stopped-machine procedure and confirm expected target travel remains in the documented working region.
Verify the as-left electrical reading, monitor indication and operating response before return to service.
Alternative Names
Technical notes
Installation relationship: Preserve the probe tag, axial reference, reach and lock position recorded for the installed machine.
Calibration boundary: Use only with the cable and 7200 signal conditioner documented for the channel.
Technical reference: Bently Nevada 7200 proximity-transducer technical information and the exact-model installed-equipment record.
FAQ View All FAQ
-
How should the custom drawing identity for 86691-01250-0400-15 be verified?Compare the complete code, probe tag, service location and drawing reference with the machine records. Do not decode the custom fields with a standard 21504 or current 3300 table.
-
How should the axial target travel be reviewed for 86691-01250-0400-15?Record thrust-bearing clearances and the known rotor position, then confirm that the expected travel remains inside the characterized channel span before setting the gap.
-
Which signal conditioner can be connected to 86691-01250-0400-15?Use only the conditioner and cable combination documented for the installed 7200 channel. Confirm electrical length and calibration records rather than relying on connector fit.
-
What evidence is needed before substituting another probe for 86691-01250-0400-15?Require a documented comparison of geometry, target, cable impedance and length, signal conditioner, scale, linear range, temperature and approval requirements.
-
How should the complete marking of 86691-01250-0400-15 be recorded before removal?Photograph the full order identity, installed position, companion components and cable route. Save the stopped-machine baseline so the replacement can be returned to the same documented configuration.
-
Which companion-component check is required before installing 86691-01250-0400-15?Confirm the probe, extension cable and Proximitor or signal conditioner identities as a documented chain. Connector fit alone does not establish electrical calibration.
-
How should cable and connector integrity be tested for 86691-01250-0400-15?Isolate the channel, inspect contacts for moisture, contamination and damage, verify continuity and insulation with an approved method, and support the cable so the connector carries no tensile load.
-
What commissioning evidence should be retained for 86691-01250-0400-15?Retain complete markings, mechanical datum, companion identities, wiring or chain-length checks, as-left measurements and the operating response accepted by the maintenance authority.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
86691-01250-0400-15Product Details -
9200-06-02-10-00Product Details -
9200-02-01-10-00Product Details -
76680-00-06-50-0-2Product Details -
9200-01-05-10-00Product Details -
991-06-70-01-00Product Details -
9324-RLD700NXENEProduct Details -
330930-040-04-CNProduct Details -
330980-50-CNProduct Details -
2711P-B7C4D1Product Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.