Match the complete marking
Include 330930-060-00-00 and every revision or approval marking visible on the item. Keep the exact reference on the enquiry and quotation.
-
Check the offered item before ordering
Request available label and interface photographs. Compare the offered 330930-060-00-00 with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 330930-060-00-00 3300 NSV
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330930-060-00-00
-
Weight:0.12 kg
-
Tariff Code:8537101190
-
Cable family:3300 XL NSv extension cable
-
Cable length:6.0 m (19.7 ft)
-
Connector and cable option:00 - Without stainless-steel armor
-
Agency approval option:00 - Not required
-
Electrical construction:75 ohm coaxial cable
-
Insulation:FEP
-
Typical capacitance:69.9 pF/m
-
Center-conductor resistance:0.220 ohm/m
-
Shield resistance:0.066 ohm/m
-
Connector material:Gold-plated brass
-
Minimum bend radius:25.4 mm
-
Operating and storage temperature:-52 to +177 deg C
-
Matched system lengths:5 m or 7 m including probe lead and extension cable
Information
- 330930-060-00-00 carries the NSv signal over 6.0 m of standard FEP-insulated coaxial cable without armor and without an approval option.
Small-target signal continuity: The unarmored 75 ohm path preserves the matched response required by NSv measurement geometry.
Connector-led serviceability: Gold-plated ClickLoc interfaces support controlled field exchange with finger-tight assembly.
The coaxial route must retain controlled support and bend radius while the gold-plated ClickLoc interfaces remain clean, dry and finger-tight. Silicone tape or approved connector protection may be applied only under the documented installation practice.
Commissioning proves the entire small-target chain: verify total length, stable 1.0 mm operating gap, bias, runout and channel response under the actual target and spacing conditions.
330930-060-00-00 Technical Reference
Bently Nevada 3300 XL NSv Proximity Transducer System Datasheet 147385 Rev. R. Selected pages retain the applicable family data, order structure and system boundary without reseller material.330930-060-00-00 Installation and Commissioning Guide
Field-focused decisions for identity capture, mechanical and electrical fit, controlled installation, diagnostics and handover.
Application scope: Restricted-clearance use: Apply 330930-060-00-00 where a seven-metre NSv chain supports small-shaft, side-view or counterbore-limited measurement.
Seven-metre transducer chain
Combine with a verified 1.0 m NSv probe lead and matching 7 m Proximitor Sensor.Small-shaft compressor points
Retain the calibrated cable path used by restricted-clearance radial or axial measurements.Unarmored protected route
Use conduit or approved supports where abrasion or mechanical exposure is possible.Controlled NSv maintenance
Restore connector identity, total length and the accepted live-gap baseline together.
Confirm the 6.0 m cable length and both endpoint labels before disconnection.
Avoid tensile load, sharp edges and bends below 25.4 mm.
Inspect both interfaces and make finger-tight locked connections.
Confirm the actual probe lead and Proximitor Sensor length designation.
Do not use a cable change to compensate for incorrect gap, target size or probe spacing.
Compare gap voltage, runout and operating response with the accepted pre-work record.
Alternative Names
Technical notes
Exact cable execution: 6.0 m standard NSv coaxial extension cable without armor
Matched-chain requirement: Probe lead plus extension cable must equal the selected Proximitor Sensor length
Technical reference: Bently Nevada 3300 XL NSv Proximity Transducer System Datasheet 147385 Rev. R
FAQ View All FAQ
-
Which probe length normally completes 330930-060-00-00 as a seven-metre NSv chain?A documented 1.0 m NSv probe lead plus the 6.0 m extension cable totals 7 m; confirm both markings before assembly.
-
Why must 330930-060-00-00 remain part of a matched NSv system?Cable length and electrical characteristics affect the scale and linear response produced by the probe and Proximitor Sensor together.
-
How should 330930-060-00-00 be protected without stainless-steel armor?Use approved routing support or conduit and prevent abrasion, pulling and sharp bending along the full run.
-
What ClickLoc handling is required for 330930-060-00-00?Keep the contacts dry, align the connector bodies and tighten by hand until the locking action is established.
-
Can 330930-060-00-00 correct a restricted-target response error?No. Target size, probe spacing, counterbore and operating gap must be corrected mechanically; the cable only preserves the documented signal path.
-
Which resistance checks can support acceptance of 330930-060-00-00?Use the documented per-metre conductor and shield values with an approved test method, then record insulation condition before connection.
-
What does option 00 establish on 330930-060-00-00?The cable is the standard unarmored execution and does not request an agency-approval option.
-
How is the restored channel proven after installing 330930-060-00-00?Set the approved gap, confirm stable bias and compare runout plus the intended radial, axial or phase response with the baseline.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
330930-060-00-00 3300 NSVProduct Details -
330905-00-08-10-02-CNProduct Details -
330104-00-05-10-02-CNProduct Details -
330104-02-12-50-02-00Product Details -
330180-X1-CN MOD:145193-09Product Details -
330104-08-15-10-02-CNProduct Details -
330104-00-05-10-11-00Product Details -
330104-15-23-50-02-00Product Details -
330104-08-14-10-02-05Product Details -
330104-00-08-05-02-05Product Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.