Match the complete marking
Include 330704-000-060-90-02-CN and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered 330704-000-060-90-02-CN reference with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 330704-000-060-90-02-CN
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330704-000-060-90-02-CN
-
Weight:0.98 kg
-
Tariff Code:8537101190
-
Probe family:3300 XL 11 mm
-
Mounting thread:M14 x 1.5
-
Cable armor:Stainless-steel armor
-
Unthreaded length:0 mm
-
Overall case length:60 mm
-
Total probe length:9.0 m
-
Connector:ClickLoc, standard cable without connector protector
-
Approval selection:CN suffix retained; verify delivered approval marking
-
Nominal probe resistance:8.5 +/-1.1 ohm
-
Matched-system linear range:4.0 mm (160 mil)
-
Matched-system scale factor:3.94 V/mm (100 mV/mil)
-
Recommended gap:2.5 mm (100 mil)
-
Matched-system frequency response:0 to 8 kHz, +0/-3 dB typical
-
Probe cable impedance:75 ohm triaxial
-
Reference target:AISI 4140 steel, 31 mm diameter or larger
-
Minimum bend radius:25.4 mm
-
Probe temperature:-52 to +177 deg C operating and storage
Information
- The 9.0 m integral armored lead distinguishes 330704-000-060-90-02-CN from the other 11 mm probes and makes route planning, resistance and connector location central to acceptance.
Long armored lead: 9.0 m standard 75 ohm triaxial lead with stainless-steel armor and ClickLoc termination.
Country-specific suffix: CN is retained in the full marking; confirm the delivered approval label rather than inferring it.
The 9.0 m integral lead can form the complete probe-side electrical length without an added extension cable when matched to the corresponding 9 m Proximitor configuration. Its stainless armor needs planned clamps and bend space; the option 02 ClickLoc joint still requires a clean protected termination area.
For the 9.0 m probe selection, nominal probe resistance is 8.5 +/-1.1 ohm and the matched 11 mm response remains 4.0 mm at 3.94 V/mm under stated conditions. Confirm the CN marking, continuity, long-route integrity and channel response as separate acceptance gates.
-
Bently Nevada 330704-000-060-90-02-CN official technical excerpt
Selected manufacturer pages covering the applicable family, technical data and exact order-code fields. -
Bently Nevada 330704-000-060-90-02-CN engineering guide
Apter Power installation, configuration, diagnostic and acceptance guidance.
Platform applications: The uses below require the documented 3300 XL 11 mm proximity transducer system companion components and approved machine drawing.
-
Remote 9 m Proximitor route
Use where the machine design calls for a long integral probe lead to a remote matching 9 m Proximitor Sensor. -
Armored machinery run
Apply along an approved route needing stainless-steel cable protection and planned support points. -
Short-case metric port
Use the 60 mm M14 x 1.5 body where the target is reached without a separate unthreaded standoff. -
CN-marked installed-base renewal
Match the full CN suffix, integral lead architecture and approval label when replacing the existing unit.
First confirm the installed nine-meter architecture because this probe already carries a 9.0 m integral lead.
Locate clamps and bends before mounting; the long armor can transmit torque back to the short case.
Keep M14 x 1.5 engagement within 21 mm to prevent case binding.
The ClickLoc termination has no connector protector; keep it clean, dry and mechanically unloaded.
Do not assign approval coverage from the suffix alone; compare the delivered label with the project requirement.
Record resistance, static output and controlled displacement response before releasing the remote channel.
Alternative Names
Technical notes
Direct nine-meter path: Confirm whether the installed architecture uses the 9.0 m probe directly to the matching Proximitor; do not add an extension cable by habit.
Armored route plan: Provide supports and a 25.4 mm minimum bend radius along the full route without using the armor as a pulling member.
CN identity: Photograph the complete suffix and delivered approval marking, then retain them with the 8.5 +/-1.1 ohm continuity result.
FAQ View All FAQ
-
Does 330704-000-060-90-02-CN normally require a separate extension cable?Its selected probe lead is already 9.0 m, so first verify the recorded architecture and matching 9 m Proximitor before adding any extension cable.
-
How should the 9.0 m armor of 330704-000-060-90-02-CN be installed?Pre-plan supports and bends, maintain at least 25.4 mm radius and prevent the route from applying torque or tension to the 60 mm case.
-
What does the CN suffix require the technician to verify on 330704-000-060-90-02-CN?Retain the full suffix and inspect the actual delivered approval marking; the suffix alone is not a substitute for the label.
-
Which resistance result is expected for the long lead on 330704-000-060-90-02-CN?The nominal probe resistance is 8.5 +/-1.1 ohm, useful for continuity diagnosis before connecting the Proximitor.
-
Why is option 02 a maintenance concern on 330704-000-060-90-02-CN?It uses a standard ClickLoc termination without a protector, so the remote joint needs its own clean, dry and strain-relieved location.
-
How is the short 60 mm case of 330704-000-060-90-02-CN positioned safely?Limit M14 x 1.5 engagement to 21 mm, verify the zero-standoff datum and ensure the armored route does not rotate the body.
-
What proves the complete 9 m channel after installing 330704-000-060-90-02-CN?Confirm the Proximitor length option, record static gap or bias and test the required displacement response against the monitor baseline.
-
Which architecture difference blocks a direct substitute for 330704-000-060-90-02-CN?A shorter probe plus extension cable changes the number and location of joints, resistance distribution and route even if the nominal total length is nine meters.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
330704-000-060-90-02-CNProduct Details -
XO08R1 XOO8R1-B04 1SBP260101R1001Product Details -
330104-00-10-20-12-05Product Details -
330101-00-10-10-02-05Product Details -
330101-00-30-05-02-00Product Details -
330103-00-03-05-01-05Product Details -
330102-00-60-05-02-05Product Details -
07NG63R1 GJV3074313R1Product Details -
07KP64 GJR5240600R0101Product Details -
07EA61R1 GJV3074351R1Product Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.