Match the complete marking
Include 31000-26-05-20-041-01-024 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered 31000-26-05-20-041-01-024 reference with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 31000-26-05-20-041-01-024
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:31000-26-05-20-041-01-024
-
Weight:1.5 kg
-
Tariff Code:8537101190
-
Housing series:31000
-
Installed probe option:3300 XL NSv probe
-
Probe cable length:0.5 m
-
Standoff adapter:2.0 in (50.8 mm)
-
Probe penetration:4.1 in (104 mm)
-
Fittings:One 3/4-14 NPT fitting and two plugs
-
Mounting interface:Final code 024 is not decoded by the reviewed current standard table; verify the actual thread from the nameplate and machine drawing
-
Housing material:Glass-reinforced PPS housing with stainless-steel sleeve hardware
-
Environmental protection:Type 4X and IP66; not explosion-proof or pressure-rated
-
Typical assembly mass:1.2 kg typical
-
Penetration adjustment:+/-0.5 in (13 mm)
-
Sleeve-support rule:Add support when standoff plus penetration exceeds 12 in (305 mm)
-
Primary installation:Externally accessible radial probe mounting through a machine case
-
Safety boundary:Housing is mechanical/environmental protection, not a pressure vessel
Information
- The complete 31000-26-05-20-041-01-024 identity fixes the offered mechanical and cable configuration; installed performance still depends on the documented companion components, target and monitoring channel.
Ordered reach: Standoff 2.0 in (50.8 mm); penetration 4.1 in (104 mm).
Mechanical interface: Final code 024 requires nameplate and machine-drawing confirmation; One 3/4-14 NPT fitting and two plugs.
The selected fitting set is One 3/4-14 NPT fitting and two plugs; the mounting interface is Final code 024 requires nameplate and machine-drawing confirmation. Inspect sleeve support, conduit direction, sealing surfaces, retaining hardware and cable clearance before setting the probe.
The housing provides access and environmental protection but does not create the electrical measurement by itself. Final acceptance must verify the probe, extension cable and Proximitor relationship, restored gap or bias, cover closure and monitor response.
-
Bently Nevada 31000-26-05-20-041-01-024 technical reference
Apter Power reference with verified manufacturer data and exact-model applicability. -
Bently Nevada 31000-26-05-20-041-01-024 engineering guide
Apter Power installation, configuration, diagnostic and acceptance guidance.
Platform applications: The uses below depend on the installed controller configuration and approved system design.
-
Radial shaft vibration
Use a documented bearing location and matched transducer chain to measure shaft motion relative to the probe mounting. -
Axial position
Aim the probe at an approved conductive thrust target and keep the full expected travel inside the characterized working region. -
Phase or speed reference
Use only with an approved once-per-turn target feature and a monitoring channel configured for phase or speed reference. -
Installed-channel maintenance
Preserve the exact probe, cable, Proximitor, mounting geometry and machine baseline recorded for the existing channel.
Match every field of 31000-26-05-20-041-01-024 with the installed spare-parts record before removal or installation.
Keep the probe tip, connector and cable free from impact, moisture, metal chips and unsupported loading.
Record reach, thread engagement, lock position and target relationship before disturbing the installed component.
Maintain the approved bend radius, separation and strain relief; do not twist, kink or crush the coaxial path.
Use the approved stopped-machine procedure to restore gap or bias and verify expected target travel.
Verify the as-left electrical reading, monitor indication and operating response before return to service.
Alternative Names
Technical notes
Installation relationship: Combine the 2.0 in (50.8 mm) standoff and 4.1 in (104 mm) penetration with the machine-case datum to establish probe position.
Protection boundary: Type 4X and IP66; not explosion-proof or pressure-rated; the housing does not establish process-pressure containment or complete intrinsically safe approval.
Technical reference: Bently Nevada 31000 and 32000 Proximity Probe Housing Assemblies Datasheet, 141610 Rev. R.
FAQ View All FAQ
-
How should the final 024 field of 31000-26-05-20-041-01-024 be verified?The current manufacturer table does not decode 024 as a standard 31000 mounting-thread option. Confirm the actual label, sleeve and machine-case thread before installation; do not force a standard option onto this identity.
-
When does 31000-26-05-20-041-01-024 require additional sleeve support?Provide support near the probe whenever standoff plus penetration exceeds 12 in (305 mm), and review shorter long-reach installations for resonance under machine vibration.
-
How should the fittings on 31000-26-05-20-041-01-024 be inspected?Confirm the exact supplied arrangement—One 3/4-14 NPT fitting and two plugs—then verify sealing, cable clearance, conduit direction and unused-port closure.
-
What must be proved after setting the probe in 31000-26-05-20-041-01-024?Tighten the retaining arrangement to the documented method, restore the approved gap or bias, and prove monitor indication and operating response before closing the cover.
-
What evidence should be captured before removing 31000-26-05-20-041-01-024?Photograph the complete 31000-26-05-20-041-01-024 marking, installed datum, connector, cable route and companion electronics. Record the stopped-machine baseline for the 31000 proximity probe housing assembly.
-
How should connector integrity be checked on 31000-26-05-20-041-01-024?Isolate the channel, inspect the coaxial contacts for moisture and damage, verify continuity only with an approved method, and provide strain relief so the connector carries no cable load.
-
What commissioning record is required for 31000-26-05-20-041-01-024?Retain the exact markings, mechanical datum, companion-component identities, as-left gap or bias, monitor indication and the accepted operating response.
-
When should 31000-26-05-20-041-01-024 be withheld from service?Do not release the channel if the complete identity, mechanical fit, cable construction, connector, approval marking or measured response differs from the approved installed record.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
31000-26-05-20-041-01-024Product Details -
74101-371-52Product Details -
330903-00-05-10-02-00Product Details -
330901-00-12-10-02-00Product Details -
330104-00-04-10-02-05Product Details -
330105-02-12-10-02-05Product Details -
330104-00-18-10-02-00Product Details -
330104-00-22-10-02-00Product Details -
330103-00-16-10-02-05Product Details -
330103-00-08-05-02-CNProduct Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.