Technical specifications for 32000-28-05-15-080-03-02
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:32000-28-05-15-080-03-02
-
Estimated shipping dimensions:45×12×10cm
-
Weight:2.2 kg
-
Tariff Code:8537101190
-
Counliy of origin:USA
-
Housing model:32000
-
Probe option:3300 XL 8 mm probe with multiple approvals
-
Probe cable length:0.5 m (20 in)
-
Standoff adapter:150 mm
-
Probe penetration:80 mm
-
Fittings:Two plugs; one M20 fitting; cable-seal grip and grommets for armored cable
-
Mounting thread:3/4-14 NPT
-
Housing material:Conductive glass-reinforced PPS
-
Probe sleeve material:AISI 304 stainless steel
-
Housing rating:IP66; Type 4X
-
Retaining-nut torque:29.4 N m (260 in-lb)
-
Probe temperature range:-51 to +177 degC
Information
- Uses the documented 32000 housing format
- Positions the probe through a 150 mm standoff and 80 mm penetration
- Provides conductive PPS environmental protection
- Supports an API 670-compatible proximity installation
32000-28-05-15-080-03-02 operates with installed 3300 XL probe, AISI 304 probe sleeve, machine-case mounting boss, selected conduit or cable-seal hardware.
Engineered applications include Bearing-case radial vibration, Axial-position probe mounting, Exposed-machine proximity point, Housing and sleeve renewal.
Important Notice: Verify 32000-28-05-15-080-03-02, 150 mm standoff, 80 mm penetration, fittings and probe-cable length; preserve sleeve support, retaining torque and enclosure sealing.
Apter Power 32000-28-05-15-080-03-02 Manuals and Guides
Apter Power 32000-28-05-15-080-03-02 System and Technical Reference PDFBently Nevada 32000-28-05-15-080-03-02 Official Engineering Document PDFThe first document provides model-specific technical and system-reference information. The second is the directly related manufacturer document used for installation, configuration and engineering verification.
Bearing-case radial vibration
Protects the installed proximity probe at the machine casing.
Axial-position probe mounting
Provides controlled access to probe gap adjustment.
Exposed-machine proximity point
Routes the probe lead into the selected field conduit.
Housing and sleeve renewal
Retains the engineered standoff and penetration during service.
Verify 32000-28-05-15-080-03-02, 150 mm standoff and 80 mm penetration before work.
Place the monitored machine and protection channel in the approved maintenance state.
Preserve the 3/4-14 NPT machine-case thread and established housing orientation.
Record probe gap, sleeve position, cable route, fitting and grommet selection before removal.
Protect the conductive PPS cover, sleeve bore, probe tip and seals from impact or contamination.
Match the probe, cable length and approval marking to the installed monitoring loop.
Apply the documented retaining-nut torque and support the sleeve against conduit or cable load.
Verify gap voltage, dynamic response, alarm action and IP66 closure before service.
Technical notes
FAQ View All FAQ
-
What is the documented system role of 32000-28-05-15-080-03-02?32000-28-05-15-080-03-02 is 32000 proximity probe housing assembly. It provides an externally adjustable proximity-probe housing that protects the probe, sleeve and cable connection at an industrial machine case.
-
Which host hardware must be matched with 32000-28-05-15-080-03-02?Match 32000-28-05-15-080-03-02 with the documented 32000 Proximity Probe Housing Assembly and the installed installed 3300 XL probe, AISI 304 probe sleeve.
-
How should the complete 32000-28-05-15-080-03-02 identification be verified?Compare the full marking with the controlling 141610 Rev. R record; the documented housing model is 32000.
-
What connection check is required before installing 32000-28-05-15-080-03-02?Record probe gap, sleeve position, cable route, fitting and grommet selection before removal.
-
How should 32000-28-05-15-080-03-02 be protected during handling?Protect the conductive PPS cover, sleeve bore, probe tip and seals from impact or contamination.
-
What configuration must be restored after replacing 32000-28-05-15-080-03-02?Match the probe, cable length and approval marking to the installed monitoring loop.
-
What commissioning test is required for 32000-28-05-15-080-03-02?Verify gap voltage, dynamic response, alarm action and IP66 closure before service.
-
Can 32000-28-05-15-080-03-02 replace a visually similar part directly?No direct substitution should be assumed. Match the complete 32000-28-05-15-080-03-02 code, interfaces, system length or mounting arrangement, and the approved host configuration.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.