32000-28-05-15-080-03-02 operates with installed 3300 XL probe, AISI 304 probe sleeve, machine-case mounting boss, selected conduit or cable-seal hardware.
Engineered applications include Bearing-case radial vibration, Axial-position probe mounting, Exposed-machine proximity point, Housing and sleeve renewal.
Important Notice: Verify 32000-28-05-15-080-03-02, 150 mm standoff, 80 mm penetration, fittings and probe-cable length; preserve sleeve support, retaining torque and enclosure sealing.
The first document provides model-specific technical and system-reference information. The second is the directly related manufacturer document used for installation, configuration and engineering verification.
Protects the installed proximity probe at the machine casing.
Provides controlled access to probe gap adjustment.
Routes the probe lead into the selected field conduit.
Retains the engineered standoff and penetration during service.
Verify 32000-28-05-15-080-03-02, 150 mm standoff and 80 mm penetration before work.
Place the monitored machine and protection channel in the approved maintenance state.
Preserve the 3/4-14 NPT machine-case thread and established housing orientation.
Record probe gap, sleeve position, cable route, fitting and grommet selection before removal.
Protect the conductive PPS cover, sleeve bore, probe tip and seals from impact or contamination.
Match the probe, cable length and approval marking to the installed monitoring loop.
Apply the documented retaining-nut torque and support the sleeve against conduit or cable load.
Verify gap voltage, dynamic response, alarm action and IP66 closure before service.