Match the complete marking
Record the complete 1746SC-INI4VI label, its Spectrum Controls revision and the installed SLC 500 slot reference. Use the same identity in the enquiry and quotation.
-
Check the offered item before ordering
Request available module label and terminal photos. Have your maintenance team compare the offered 1746SC-INI4VI with the installed SLC 500 equipment and applicable Allen-Bradley and Spectrum Controls documentation.
Technical specifications for 1746SC-INI4VI
-
Manufacturer:Allen-Bradley
-
Product Category:PLC Systems
-
Spare Part Number:1746SC-INI4VI
-
Weight:0.2 kg
-
Tariff Code:8537101190
-
Input channels:4 individually configurable differential inputs
-
Current ranges:0-20 mA or 4-20 mA
-
Voltage ranges:0-5 V, 1-5 V, 0-10 V or ±10 V
-
Conversion resolution:16 bits
-
Module ID code:3520
-
Configuration words:O:e.0 through O:e.3, one per channel
-
Channel isolation:125 VAC continuous
-
Field-to-backplane isolation:125 VAC continuous
-
Voltage input impedance:Greater than 220 kΩ
-
Current input impedance:Less than 250 Ω
-
Backplane requirement:5 V at 550 mA typical; 24 V at 0 mA
-
Current-input protection:33 mA continuous, 70 mA transient
-
Voltage-input protection:50 VDC continuous
-
Operating temperature:0 to 60 °C
Information
- The installed SLC 500 program configures each isolated input channel and interprets its status and data words. The module measures field signals; it does not supply loop excitation.
Channel setup: Current or voltage selection is configured channel by channel
Host exchange: SLC slot ID and image words determine controller access
Acceptance focus: Check channel scaling, filter choice and live readings against the loop schedule
The Spectrum Controls user manual assigns module ID code 3520 to the 1746sc-INI4vi and uses output image words O:e.0 through O:e.3 for channel configuration. The selected filter, engineering scale and fault-handling choices must match the application program and sensor wiring.
The datasheet specifies 16-bit resolution and typical 5 V backplane draw of 550 mA for the voltage/current variant. For 4-20 mA loops, the module measures current but does not provide transmitter excitation, so the field loop must have its specified external supply arrangement.
-
Spectrum Controls 1746SC-INI4VI user manual excerpt
Original Spectrum Controls User's Manual Pub. 0300127-06 Rev. A0 - selected pages, PDF, 5 pages. Module overview, input specifications and regulatory requirements. -
Allen-Bradley 1746SC-INI4VI installation guide
Prepared by Apter Power - PDF, 5 pages. Identification, installation checks, commissioning and fault isolation.
Application scope: Use the isolated channels where independent voltage or current signals must be acquired by the configured SLC program.
-
Mixed analog acquisition
Configure each channel for the connected voltage or current instrument without assuming a common range across all four loops. -
Isolated field circuits
Bring separately referenced measurements into one SLC module while respecting the documented channel and backplane isolation boundaries. -
Process signal monitoring
Map measured values and channel status into the host program for application-specific display, alarms or control decisions. -
Maintenance replacement
Retain the original slot address, channel configuration, scaling and sensor supply arrangement during an exact-model exchange.
Confirm the 1746 chassis location and module ID code 3520 in the SLC I/O configuration before energizing.
Isolate field supplies and compare polarity, shield termination and each terminal assignment with the installed drawing.
A 4-20 mA transmitter needs its specified external supply; the input module does not power the loop.
Save each range, filter, scale limit and fault response from the controller project before removing the old module.
Include the voltage/current variant’s typical 550 mA demand on the 5 V backplane when checking the chassis supply.
After replacement, apply a known signal to all four channels and compare raw values, engineering units and diagnostic bits with the pre-work record.
Alternative Names
Technical notes
Installation relationship: Use the SLC 500 slot definition, four channel configuration words and individual field-loop drawings as one system.
Signal protection: The module does not source loop excitation; check external supplies and respect the documented isolation and input protection limits.
Technical reference: Spectrum Controls 1746sc-INI4i/INI4vi Datasheet, PN 0100362-01 Rev. E, and User Manual, Pub. 0300127-06 Rev. A0. Rockwell documentation identifies the SLC-compatible module.
FAQ View All FAQ
-
How is each input of 1746SC-INI4VI changed between current and voltage operation?Set the individual channel configuration word for the required signal type and range, then compare terminal wiring and the field instrument with that selection. A common setting across all four channels is not required.
-
Why can a 4-20 mA transmitter connected to 1746SC-INI4VI read zero?The module measures loop current but does not provide excitation. Check the external transmitter supply, loop continuity, polarity, configured range and channel status before suspecting the converter.
-
What SLC module ID should be entered for 1746SC-INI4VI?The Spectrum Controls manual assigns ID code 3520 to the 1746sc-INI4vi. Confirm the actual slot and the controller program’s I/O configuration before writing or downloading the project.
-
Which output image words configure the channels of 1746SC-INI4VI?Output words O:e.0 through O:e.3 configure channels 0 through 3 respectively, where e is the installed slot number. Preserve the existing channel-to-loop map when changing hardware.
-
What does channel isolation mean for 1746SC-INI4VI field wiring?The datasheet specifies 125 VAC continuous channel-to-channel and field-to-backplane isolation. These ratings do not remove the need to follow the complete circuit and grounding design.
-
How should a noisy reading on 1746SC-INI4VI be investigated?Compare the selected digital filter with the signal bandwidth, inspect shielded twisted-pair routing and grounding, then test a known source at the affected channel to separate field noise from a module issue.
-
Can 1746SC-INI4VI replace a current-only 1746sc-INI4i without reviewing the program?Do not assume drop-in equivalence. The INI4vi permits voltage or current selection and has its own module ID, power requirement and configuration. Compare the complete marking, slot definition and channel setup.
-
What functional test should close a 1746SC-INI4VI replacement?Inject representative low, middle and high signal values into each configured channel, check raw and scaled readings and confirm alarm or fault behavior in the SLC application.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.