Match the complete marking
Include 1746-NIO4I and any visible series or assembly marking in the enquiry and quotation.
-
Check the offered item before ordering
Request available label and terminal photographs. Have maintenance compare the offered reference with the installed SLC module and Rockwell documentation before ordering.
Technical specifications for 1746-NIO4I
-
Manufacturer:Allen-Bradley
-
Product Category:PLC Systems
-
Spare Part Number:1746-NIO4I
-
Weight:0.2 kg
-
Tariff Code:8537101190
-
Module family:SLC 500 1746 analog I/O
-
Analog inputs:2 differential; voltage or current selectable per channel
-
Analog outputs:2 current outputs; 0-20 mA normal
-
Channel isolation:Inputs and outputs not individually isolated
-
Backplane 5 V draw:55 mA maximum
-
Backplane 24 V draw:145 mA maximum
-
Field-to-backplane isolation:500 V DC
-
SLC data format:16-bit two-complement binary
-
Analog update:512 microseconds for all channels in parallel
-
Current-input range:-20 to +20 mA normal
-
Current-input impedance:250 ohms
-
Current-input resolution:1.22070 microamps per LSB
-
Current-input accuracy at 25 C:+/- 0.365% of full scale maximum
-
Current-output range:0-20 mA; 5% overrange to 21 mA minus 1 LSB
-
Current-output resolution:14 bit; 2.56348 microamps per LSB
-
Current-output load:0-500 ohms
-
Current-output step response:2.5 ms to 95%
-
Current-output accuracy at 25 C:+/- 0.298% of full scale maximum
-
Removable terminal block:Yes
-
Recommended cable:Shielded Belden 8761
-
Maximum wire size:14 AWG
-
Operating temperature:0 to 60 C
-
Storage temperature:-40 to +85 C
-
Relative humidity:5-95% non-condensing
-
Manufacturer lifecycle:Discontinued 29 April 2021; engineering replacement
-
Item origin:USA, confirmed from supplied physical unit
-
Shipping package:3.5cm x 13cm x 14.5cm; 0.2kg
Information
- Allen-Bradley 1746-NIO4I provides two selectable differential analog inputs and two current outputs in an SLC 500 1746 chassis slot.
Field channels: 2 inputs and 2 current outputs
Chassis: 1746 SLC 500
Each input can be configured for voltage or current. Current inputs operate over -20 to +20 mA with 250 ohm impedance; the two outputs normally provide 0-20 mA with a 0-500 ohm load range. Verify process-transmitter wiring and PLC scaling for each channel.
The removable terminal block and shielded cable arrangement support field maintenance. Analog commons are internally connected and the channels are not isolated from each other. The 500 V DC isolation is from field wiring to the backplane; design grounding around this boundary.
-
1746-NIO4I technical reference excerpt
Original Rockwell manual, 6 selected pages: module identity, chassis power, analog input and current-output specifications. -
1746-NIO4I engineering technical data
Analog channels, signal ranges, backplane load, isolation and commissioning checks. Apter Power PDF, 1 page.
Application boundary: Match the actual rack, transmitter wiring, PLC program and output loads to the documented module limits.
-
Process-signal acquisition
Read two differential analog process inputs after confirming voltage/current selection and the controller scaling for each channel. -
Current-loop actuation
Drive two 0-20 mA field loads while respecting the 0-500 ohm load range and the site wiring design. -
SLC rack integration
Account for the module demand on both 5 V and 24 V backplane rails and retain the expected 1746 slot/I-O image. -
Service replacement
Transfer terminal labeling, program settings and grounding practice, then prove each input and output with calibrated signals.
Disconnect SLC power and any other field source before wiring or removing the analog module.
Include 55 mA at 5 V and 145 mA at 24 V in the installed supply calculation.
Keep input and output returns aligned with the approved wiring diagram; analog commons are internally joined.
Use the manufacturer shield-grounding method and route analog cables away from noisy power conductors.
Measure the actual loop load and confirm that each output stays within 0-500 ohms.
Restore slot, mode and scaling settings; inject known inputs and verify both field outputs before release.
Alternative Names
Technical notes
Module: 1746-NIO4I combines two selectable voltage/current differential inputs with two analog current outputs. The analog channels are not individually isolated.
Power and wiring: Verify SLC 5 V and 24 V backplane capacity, field common, shield termination and 0-500 ohm current-output load before installation.
Technical source: Rockwell Automation 1746-IN008C-EN-P, May 2004; exact product record.
FAQ View All FAQ
-
Why can an input reading drift on 1746-NIO4I while the transmitter current is stable?Check shield grounding, analog common, loop supply, input mode and temperature. Trend a calibrated loop signal at the terminal block before replacing hardware.
-
How should a PLC engineer check the two input modes of 1746-NIO4I before replacement?Compare the installed channel selection, terminal wiring and controller scaling with the application file. Prove each channel with a known current or voltage stimulus as appropriate.
-
What can make a current output on 1746-NIO4I saturate before reaching its commanded value?Measure loop resistance and supply conditions at the actual load; confirm the 0-500 ohm specification, wiring polarity and output scaling.
-
How should backplane power be checked before adding 1746-NIO4I to a full SLC chassis?Sum the rack 5 V and 24 V loads from the installed modules and compare with the supply margin.
-
What is the correct isolation assumption for channels on 1746-NIO4I?Field wiring is isolated from the backplane but individual analog channels are not isolated from each other. Design grounding and common returns accordingly.
-
How can noise on 1746-NIO4I analog values be investigated?Inspect shield termination, cable routing, analog common, grounding and transmitter supply; compare a stable reference input with live process readings.
-
What should be backed up before swapping 1746-NIO4I in an operating rack?Record slot position, terminal labeling, channel mode and scaling, PLC program, fault history and as-found values for all four channels.
-
How should a replacement for discontinued 1746-NIO4I be validated?Rockwell lists an engineering replacement category. Check controller, I/O image, wiring, scaling and application behavior with Rockwell guidance before selecting an alternative.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.