Speak to a sourcing specialist
sales13@apterpower.com

SNAT609TAI SNAT 609 TAI

ACV 700 Tacho and I/O Interface Board
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

ABB SNAT609TAI is the tacho and I/O interface board for the ACV 700 drive controller, with flat-cable, fibre and jumper selections tied to the installed inverter execution.
  • Manufacturer part number
    SNAT609TAI SNAT 609 TAI
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    26.1cm x 13.8cm x 1.5cm
  • Country of Origin
    Sweden
Get a quick price for SNAT609TAI SNAT 609 TAI
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete SNAT609TAI SNAT 609 TAI marking with board type, documented function, current-unit photographs and required quantity.
  • 1

    Confirm the offer

    For SNAT609TAI SNAT 609 TAI, confirm drive family, motor-control board interface, included items and the documented ABB ACV 700 digital drive controller fit.
  • 2

    Arrange dispatch

    Approve the SNAT609TAI SNAT 609 TAI quantity after checking field I/O and tacho interface; record the agreed dispatch date and delivery details.
  • Match the complete marking

    Send the complete SNAT609TAI SNAT 609 TAI marking, revision labels, current-unit photographs and installed position.

  • Check the offered item before ordering

    Compare the offered SNAT609TAI SNAT 609 TAI interfaces, ratings and included items with the approved system record before ordering.

Technical specifications for SNAT609TAI SNAT 609 TAI

  • Manufacturer:
    ABB
  • Product Category:
    General Automation
  • Spare Part Number:
    SNAT609TAI SNAT 609 TAI
  • Weight:
    0.26 kg
  • Tariff Code:
    8537101190
  • Product type:
    ACV 700 Tacho and I/O Interface Board
  • System platform:
    ABB ACV 700 digital drive controller
  • Documented function:
    Tacho and I/O interface
  • Drive family:
    ACV 700
  • Motor-control board interface:
    SNAT 603 CNT via 36-pole flat cable
  • Field I/O and tacho interface:
    SNAT 602 TAC via 40-pole flat cable
  • APC communication:
    Fibre-optic link
  • IGBT interface:
    SNAT 7261 INT via 20- and 40-pole flat cables
  • GTO interface:
    SNAT 607 MCI via 10-, 20- and 40-pole flat cables
  • Inverter-number selection:
    Positions 1 through 4
  • Constant-current selections:
    1.6 mA or 9 mA per channel
  • Tacho-channel control:
    Edge-oscillation inhibition jumpers

Information

Overview Downloads Applications / Compatibility Product Precautions
  • SNAT609TAI provides the ACV 700 controller interface for tacho feedback and drive I/O, with connection choices that differ between documented IGBT and GTO arrangements.
Drive-signal concentration: The board brings tacho, field I/O and motor-control signals together in the ACV 700 controller.
Power-stage dependent cabling: IGBT and GTO executions use different companion boards and ribbon-cable combinations.
Jumper-defined behavior: Inverter number, constant-current channels and tacho inhibition must be copied from the removed board.
SNAT 609 TAI is the ABB ACV 700 tacho and I/O interface board. It routes field I/O and tachometer signals through SNAT 602 TAC and exchanges control signals with SNAT 603 CNT.

Its companion main-circuit interface differs between IGBT and GTO power stages. The board also carries fibre-optic communication to the APC and jumper selections for inverter identity, current channels and tacho input behavior.

Before replacement, photograph all jumpers and flat cables and export drive parameters. After installation, verify auxiliary supplies, tacho feedback, I/O status, fibre communication and controlled motor response.
Controller platform reference: ABB ACV 700 drive controller. Follow approved ABB instructions.
References for SNAT609TAI SNAT 609 TAI cover aCV 700 Tacho and I/O Interface Board, its ABB ACV 700 digital drive controller relationship and a separate field-verification procedure.
Use the technical reference for motor-control board interface and field I/O and tacho interface; use the field guide to retain installation and commissioning records.
System fit: SNAT609TAI SNAT 609 TAI belongs in an ACV 700 control assembly whose CNT/TAC connections, optical links, auxiliary supplies and jumpers match the installed inverter.

Selection impact: Replacement requires the same current-scaling, tacho and I/O selections; photograph every connector and jumper because an adjacent SNAT board number does not establish compatibility.
Before servicing SNAT609TAI SNAT 609 TAI, save drive parameters, photograph every jumper and preserve its ABB ACV 700 digital drive controller relationship.
Save drive parameters

Back up motor, I/O and regulator records.

Photograph every jumper

Retain inverter, current and tacho selections.

Map all flat cables

Separate CNT, TAC, IGBT and GTO interfaces.

Protect fibre connections

Cap, clean and preserve cable routing.

Check auxiliary supplies

Verify rails and diagnostics before motor enable.

Test tacho and I/O

Prove feedback, communication and controlled drive response.

Alternative Names

ABB SNAT609TAI SNAT 609 TAI ACV 700 Tacho and I/O Interface Board SNAT609TAI SNAT 609 TAI

Technical notes

Exact identity: SNAT609TAI SNAT 609 TAI

Documented function: ACV 700 Tacho and I/O Interface Board

Technical evidence: ABB ACV 700 hardware and DDCTool documentation for SNAT 609 TAI

Evidence boundary: Only the documented ABB ACV 700 digital drive controller relationship and stated exact-model values are applied

Commissioning record: Retain installed markings, configuration and functional proof

FAQ View All FAQ

  • Which companion boards connect directly to SNAT609TAI SNAT 609 TAI?
    SNAT 603 CNT and SNAT 602 TAC are documented interfaces; the main-circuit board is SNAT 7261 INT for IGBT or SNAT 607 MCI for GTO.
  • Why must the jumper positions of SNAT609TAI SNAT 609 TAI be photographed?
    They set inverter number, constant-current selections and tacho-channel edge-oscillation inhibition.
  • Which current selections are documented on SNAT609TAI SNAT 609 TAI?
    The constant-current channel jumpers select 1.6 mA or 9 mA as shown in the ACV 700 hardware documentation.
  • How is SNAT609TAI SNAT 609 TAI connected to the APC?
    The board uses a fibre-optic link, so connector cleanliness, cable route and endpoint identity must be preserved.
  • How do IGBT and GTO cabling differ for SNAT609TAI SNAT 609 TAI?
    IGBT applications use SNAT 7261 INT with 20- and 40-pole cables; GTO applications use SNAT 607 MCI with 10-, 20- and 40-pole cables.
  • What supplies should be checked before enabling a drive with SNAT609TAI SNAT 609 TAI?
    Verify the documented auxiliary rails and board diagnostics before permitting motor control.
  • How should tacho feedback be proven after replacing SNAT609TAI SNAT 609 TAI?
    Rotate or run the machine under the approved test and compare direction, magnitude and stability with the retained baseline.
  • Which feedback checks distinguish a correct SNAT609TAI SNAT 609 TAI installation from a cabling fault?
    Verify auxiliary supplies and board diagnostics first, then compare tacho feedback, selected I/O and each documented flat-cable or optical path against the retained ACV 700 baseline.