Technical specifications for 63NHG00B-690 3ABD0001782
-
Manufacturer:ABB
-
Product Category:General Automation
-
Spare Part Number:63NHG00B-690 3ABD0001782
-
Weight:0.22 kg
-
Tariff Code:8537101190
-
Rated current:63 A
-
Rated voltage:690 V AC
-
Fuse size:NH00
-
Utilization category:gL/gG
-
Breaking capacity:120 kA
-
Status indication:Dual combination indicator
-
Gripping-lug execution:Live metal gripping lugs
-
Contact format:Square body with knife-blade contacts
-
Standards:IEC 60269-2 / DIN 43620 / VDE 0636-2
-
Body dimensions:54 mm x 30 mm x 50 mm
Information
- The complete offer combines ABB spare reference 3ABD0001782 with the 63NHG00B-690 NH00 fuse identity, including its 63 A, 690 V and gG protection data.
NH00 knife-contact format: Fuse body, live gripping lugs and holder geometry must agree with the installed base.
Dual indication: The combination indicator supports visual fuse-state checks while electrical isolation is still proven separately.
Procurement matches the ABB supplied reference to the complete fuse-body marking, holder size, live gripping-lug execution and indicator arrangement.
Replacement requires approved NH-fuse isolation and personal-protection controls. The holder, contact pressure, heat discoloration and downstream fault are inspected before a new fuse is installed.
63NHG00B-690 3ABD0001782 Technical Reference
Verified exact-model electrical data for 63NHG00B-690 and ABB reference 3ABD0001782. Confirm NH00 size, 63 A, 690 V AC, gL/gG and 120 kA.63NHG00B-690 3ABD0001782 Installation & Verification Guide
Field guide for confirm two identities, use NH-fuse PPE and inspect the holder during 63NHG00B-690 3ABD0001782 exchange.
Selection impact: Do not approve by NH00 size alone: the live gripping lugs, knife contacts, dual indicator, current rating and utilization category must match the installed switch-fuse assembly.
Low-voltage feeder protection
Provide full-range gG protection within the documented 690 V circuit.ABB spare-parts replacement
Reconcile 3ABD0001782 with the exact 63NHG00B-690 fuse marking.NH00 switch-fuse service
Match knife-contact geometry, live gripping lugs and holder condition.Fault-current maintenance
Investigate downstream faults and contact heating before re-energization.
Match ABB spare reference and documented fuse marking.
Follow the approved arc-flash and extraction procedure.
Check contacts, pressure, insulation and heat damage.
Resolve overload or short circuit before replacement.
Verify NH00, 63 A, 690 V, gG and 120 kA.
Record the final circuit and thermal checks.
Alternative Names
Technical notes
Exact identity: 63NHG00B-690 3ABD0001782
Documented function: NH00 Low-Voltage HRC Fuse Link
Technical evidence: ABB supplied reference 3ABD0001782 with verified exact-model NH00 electrical data
Evidence boundary: Only the documented ABB low-voltage fuse-protection relationship and stated exact-model values are applied
Commissioning record: Retain installed markings, holder inspection, fault disposition and functional proof
FAQ View All FAQ
-
How should the 120 kA breaking-capacity requirement be checked for 63NHG00B-690 3ABD0001782?Confirm the prospective fault level and approved upstream/downstream coordination before release.
-
Which holder details must match 63NHG00B-690 3ABD0001782?Confirm NH00 geometry, knife contacts, live gripping lugs, contact pressure and indicator visibility.
-
Why is gL/gG utilization important for 63NHG00B-690 3ABD0001782?The full-range characteristic covers overload and short-circuit protection in the documented low-voltage circuit.
-
What should be inspected after a 63NHG00B-690 3ABD0001782 operation?Clear the original fault and inspect holder contacts, heat discoloration, insulation and conductor condition.
-
How should dual indication be checked on 63NHG00B-690 3ABD0001782?Use the visual indication only after isolation is proven; verify the circuit electrically before return to service.
-
Which markings control acceptance of 63NHG00B-690 3ABD0001782?Retain the complete fuse marking, ABB supplied reference, 63 A and 690 V ratings, NH00 size and gL/gG class.
-
What proves correct re-energization of 63NHG00B-690 3ABD0001782?Record stable circuit operation and confirm there is no abnormal holder heating or voltage drop.
-
What belongs in the handover record for 63NHG00B-690 3ABD0001782?Keep label photographs, holder inspection, fault disposition, coordination check and controlled re-energization result.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
63NHG00B-690 3ABD0001782Product Details -
RCM 230VAC 3C/0 3ABD00029943Product Details -
PM5670-2ETH 1SAP151000R0278Product Details -
F4332D 3HAC024322-001Product Details -
HITE303278R1Product Details -
CBHX165C 5R 414Product Details -
CM592-DP 1SAP173200R0001Product Details -
3HAC14549-3/10AProduct Details -
CI532V09 3BUP001190R1Product Details -
1SDA051266R1Product Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.