Speak to a sourcing specialist
sales13@apterpower.com

63NHG00B-690 3ABD0001782

NH00 Low-Voltage HRC Fuse Link
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

ABB reference 3ABD0001782 maps to the documented NH 63NHG00B-690 NH00 fuse link, rated 63 A at 690 V AC with gG full-range protection.
  • Manufacturer part number
    63NHG00B-690 3ABD0001782
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    7.9cm x 3cm x 5.8cm
  • Country of Origin
    Sweden
Get a quick price for 63NHG00B-690 3ABD0001782
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete 63NHG00B-690 3ABD0001782 marking with ABB supplied reference, complete fuse marking, current-unit photographs and required quantity.
  • 1

    Confirm the offer

    For 63NHG00B-690 3ABD0001782, confirm fuse catalog number, rated current, included items and the documented ABB spare-parts supply mapping with documented NH fuse technology fit.
  • 2

    Arrange dispatch

    Approve the 63NHG00B-690 3ABD0001782 quantity after checking rated voltage; record the agreed dispatch date and delivery details.
  • Match the complete marking

    Send the complete 63NHG00B-690 3ABD0001782 marking, revision labels, current-unit photographs and installed position.

  • Check the offered item before ordering

    Compare the offered 63NHG00B-690 3ABD0001782 interfaces, ratings and included items with the approved system record before ordering.

Technical specifications for 63NHG00B-690 3ABD0001782

  • Manufacturer:
    ABB
  • Product Category:
    General Automation
  • Spare Part Number:
    63NHG00B-690 3ABD0001782
  • Weight:
    0.22 kg
  • Tariff Code:
    8537101190
  • Rated current:
    63 A
  • Rated voltage:
    690 V AC
  • Fuse size:
    NH00
  • Utilization category:
    gL/gG
  • Breaking capacity:
    120 kA
  • Status indication:
    Dual combination indicator
  • Gripping-lug execution:
    Live metal gripping lugs
  • Contact format:
    Square body with knife-blade contacts
  • Standards:
    IEC 60269-2 / DIN 43620 / VDE 0636-2
  • Body dimensions:
    54 mm x 30 mm x 50 mm

Information

Overview Downloads Applications / Compatibility Product Precautions
  • The complete offer combines ABB spare reference 3ABD0001782 with the 63NHG00B-690 NH00 fuse identity, including its 63 A, 690 V and gG protection data.
Full-range branch protection: The gG characteristic provides overload and short-circuit protection for the documented low-voltage circuit.
NH00 knife-contact format: Fuse body, live gripping lugs and holder geometry must agree with the installed base.
Dual indication: The combination indicator supports visual fuse-state checks while electrical isolation is still proven separately.
63NHG00B-690 is an NH00 fuse link rated 63 A at 690 V AC with gL/gG utilization and a 120 kA breaking capacity. The supplied ABB reference is 3ABD0001782.

Procurement matches the ABB supplied reference to the complete fuse-body marking, holder size, live gripping-lug execution and indicator arrangement.

Replacement requires approved NH-fuse isolation and personal-protection controls. The holder, contact pressure, heat discoloration and downstream fault are inspected before a new fuse is installed.
Controller platform reference: ABB low-voltage fuse protection. Follow approved ABB instructions.
References for 63NHG00B-690 3ABD0001782 cover exact-model NH00 electrical data, its ABB low-voltage fuse-protection relationship and a separate field-verification procedure.
Use the technical reference for rated current and rated voltage; use the field guide to retain installation and commissioning records.
System fit: 63NHG00B-690 3ABD0001782 is intended for an NH00 holder and a 690 V low-voltage circuit requiring the documented gG characteristic and 120 kA breaking capacity.

Selection impact: Do not approve by NH00 size alone: the live gripping lugs, knife contacts, dual indicator, current rating and utilization category must match the installed switch-fuse assembly.
Before servicing 63NHG00B-690 3ABD0001782, confirm two identities, use NH-fuse PPE and preserve its ABB spare-parts supply mapping with documented NH fuse technology relationship.
Confirm two identities

Match ABB spare reference and documented fuse marking.

Use NH-fuse PPE

Follow the approved arc-flash and extraction procedure.

Inspect the holder

Check contacts, pressure, insulation and heat damage.

Clear the fault

Resolve overload or short circuit before replacement.

Match the full rating

Verify NH00, 63 A, 690 V, gG and 120 kA.

Document re-energization

Record the final circuit and thermal checks.

Alternative Names

ABB 63NHG00B-690 3ABD0001782 NH00 Low-Voltage HRC Fuse Link 63NHG00B-690 3ABD0001782

Technical notes

Exact identity: 63NHG00B-690 3ABD0001782

Documented function: NH00 Low-Voltage HRC Fuse Link

Technical evidence: ABB supplied reference 3ABD0001782 with verified exact-model NH00 electrical data

Evidence boundary: Only the documented ABB low-voltage fuse-protection relationship and stated exact-model values are applied

Commissioning record: Retain installed markings, holder inspection, fault disposition and functional proof

FAQ View All FAQ

  • How should the 120 kA breaking-capacity requirement be checked for 63NHG00B-690 3ABD0001782?
    Confirm the prospective fault level and approved upstream/downstream coordination before release.
  • Which holder details must match 63NHG00B-690 3ABD0001782?
    Confirm NH00 geometry, knife contacts, live gripping lugs, contact pressure and indicator visibility.
  • Why is gL/gG utilization important for 63NHG00B-690 3ABD0001782?
    The full-range characteristic covers overload and short-circuit protection in the documented low-voltage circuit.
  • What should be inspected after a 63NHG00B-690 3ABD0001782 operation?
    Clear the original fault and inspect holder contacts, heat discoloration, insulation and conductor condition.
  • How should dual indication be checked on 63NHG00B-690 3ABD0001782?
    Use the visual indication only after isolation is proven; verify the circuit electrically before return to service.
  • Which markings control acceptance of 63NHG00B-690 3ABD0001782?
    Retain the complete fuse marking, ABB supplied reference, 63 A and 690 V ratings, NH00 size and gL/gG class.
  • What proves correct re-energization of 63NHG00B-690 3ABD0001782?
    Record stable circuit operation and confirm there is no abnormal holder heating or voltage drop.
  • What belongs in the handover record for 63NHG00B-690 3ABD0001782?
    Keep label photographs, holder inspection, fault disposition, coordination check and controlled re-energization result.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.