Match the complete marking
Include 1SDA051266R1 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered 1SDA051266R1 reference with the installed equipment and applicable ABB documentation.
Technical specifications for 1SDA051266R1
-
Manufacturer:ABB
-
Product Category:General Automation
-
Spare Part Number:1SDA051266R1
-
Weight:1.15 kg
-
Tariff Code:8537101190
-
Breaker family:SACE Tmax T3S
-
Number of poles:3
-
Trip technology:Thermomagnetic
-
Rated current:125 A
-
Breaking capacity:50 kA, catalogue table value
-
Connection requirement:Front connection terminal sets required for T3 outgoing devices
Information
- This article number identifies the complete T3S outgoing breaker selection, not a loose trip unit; pole count, frame, rating and terminal hardware must be checked together.
Interruption value: 50 kA catalogue selection for the stated T3S article.
Installation dependency: Use the specified T3 front-terminal set and verify panel clearances.
The 50 kA catalogue value must be applied within the voltage and installation conditions of the selected switchboard design; it is not a universal site fault-current statement.
ABB calls for front connection terminal sets on the referenced T3 outgoing arrangement. Confirm the offered unit includes or is paired with the required terminal hardware.
-
ABB 1SDA051266R1 official technical excerpt
Selected manufacturer pages covering the applicable family, technical data and exact order-code fields. -
ABB 1SDA051266R1 engineering guide
Apter Power installation, configuration, diagnostic and acceptance guidance.
Platform applications: The uses below require the documented ABB SACE Tmax T3 low-voltage feeder protection assembly companion components and approved machine drawing.
-
Outgoing feeder protection
Apply on a three-phase feeder whose design current and prospective fault level match the T3S selection. -
Motor branch isolation
Use only with separately coordinated motor protection and contactor equipment. -
Distribution-panel retrofit
Check cutout, bus spacing, terminal orientation and upstream discrimination before exchange. -
Fixed-load circuit protection
Confirm conductor size and thermal setting assumptions against the fixed 125 A release.
Interpret the 50 kA catalogue value only at the applicable rated-voltage condition.
The T3 outgoing arrangement requires the specified connection terminal set.
The offered thermomagnetic unit is 125 A and is not an adjustable electronic release.
Follow the approved lockout and dead-test process before handling line or load conductors.
Review upstream and downstream protective-device coordination before release.
Reject heat damage, cracked molding, loose terminals or uneven mechanism movement.
Alternative Names
Technical notes
Nameplate proof: Confirm T3S, three poles, 125 A and complete ABB article number.
Mechanical proof: Operate the mechanism through the approved test sequence and inspect all pole contact paths.
Installation proof: Record front terminals, conductor sizes, torque values and protection-coordination approval.
FAQ View All FAQ
-
Which breaker family does 1SDA051266R1 identify?It identifies an ABB SACE Tmax T3S molded-case circuit breaker.
-
How many poles are fitted to 1SDA051266R1?The catalogue article is a three-pole device.
-
What current rating is listed for 1SDA051266R1?The thermomagnetic trip unit is rated 125 A.
-
What breaking-capacity value is listed for 1SDA051266R1?The referenced catalogue table gives 50 kA under its stated selection conditions.
-
Does 1SDA051266R1 use an electronic trip unit?No. The selected article is thermomagnetic.
-
Which connection hardware is required for 1SDA051266R1?ABB notes front connection terminal sets for the T3 outgoing arrangement.
-
Can 1SDA051266R1 be selected from current alone?No. Verify voltage, fault level, poles, frame, coordination and terminal geometry.
-
What should be recorded after installing 1SDA051266R1?Record label, terminals, conductor sizes, torque, mechanism test and coordination reference.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.