Match the complete marking
Include 3HAC14549-3/10A with the complete /10A suffix and installed IRC5 drive-system identification. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available rectifier-label, connector and busbar-interface photos. Have your maintenance team compare the offered 3HAC14549-3/10A with the installed equipment and applicable ABB documentation.
Technical specifications for 3HAC14549-3/10A
-
Manufacturer:ABB
-
Product Category:Robot Systems
-
Spare Part Number:3HAC14549-3 / 10A
-
Weight:1.72 kg
-
Tariff Code:8537101190
-
Drive-system generation:04
-
Base rectifier designation:DSQC 618_R3
-
Configured drive position:Z2
-
Associated capacitor unit:DSQC 620_C3
-
Capacitor assembly reference:3HAC14551-2
-
Documented main-drive assembly:DSQC 617_3V3W
-
Main-drive reference:3HAC025338-006
Information
- IRC5 Drive System 04 distributes the rectifier, capacitor and axis-drive functions across separate components; the R3 assembly must be matched to that installed architecture.
R3 pairing: The R3 configuration is reviewed with its C3 capacitor arrangement, rather than borrowing the R2/C4 pairing.
Revision identity: Keep /10A with the offered rectifier reference; it is not used here as an electrical-current rating.
Drive System 04 and Drive System 09 both perform robot drive functions, but their power architectures differ. In System 04 the rectifier, capacitor and axis-drive components are separate; System 09 combines the main robot drive functions in a Main Drive Unit. Determine the installed generation before selecting a spare or planning external-axis work.
Rectifier replacement involves the cabinet power circuit, inter-unit busbars and the surrounding drive arrangement. Depending on the installed EPS or SafeMove option, the axis-computer assembly can affect removal access. Restore connectors, busbars, mounting orientation and any displaced assemblies using the actual cabinet circuit diagram and approved repair procedure.
-
ABB 3HAC14549-3/10A official technical excerpt
Applicable original manufacturer excerpt, PDF, 7 pages. The manual establishes the 3HAC14549-3 / DSQC 618_R3 base arrangement in Drive System 04. It does not define /10A electrical ratings; companion references describe the documented configuration, not supply contents. -
ABB 3HAC14549-3/10A engineering guide
Apter Power engineering guide, PDF, 2 pages. R3/C3 assembly review, System 04 access, connector/busbar restoration and acceptance.
Integration boundary: The R3 rectifier is evaluated within the matching System 04 power section; System 09 integration uses a different unit architecture.
-
System 04 R3 maintenance
Use the offered rectifier within a verified R3 power arrangement, retaining the complete /10A marking and installed cabinet identity. -
Capacitor coordination
Review the C3 capacitor assembly as part of the documented R3 configuration; do not transplant the R2/C4 pairing into the replacement record. -
Drive-module service
In a Dual Cabinet Controller, locate the servo-drive components in the Drive Module; the single-cabinet access arrangement is different. -
Option-dependent access
Account for the axis-computer access requirements when EPS or SafeMove hardware is installed before planning rectifier removal.
Confirm System 04 from the installed arrangement and controller documentation before selecting the repair procedure; System 09 unit instructions are not interchangeable.
Apply the IRC5 cabinet isolation and stored-energy procedure before disconnecting the rectifier or busbars. External equipment can remain energized after the robot mains are switched off.
Preserve the rectifier suffix, capacitor identity and main-drive configuration before dismantling the power section.
Check whether the installed EPS or SafeMove arrangement requires axis-computer removal for access, and retain all disturbed connections in the work record.
Refit the rectifier in its intended orientation, reconnect inter-unit busbars and every disconnected connector before restoring displaced assemblies.
After approved reassembly, complete the controller-specific power-up and functional checks with the intended robot configuration; a mechanically fitted unit alone is not acceptance.
Alternative Names
Technical notes
Power-section relationship: The System 04 rectifier, capacitor and servo-drive functions are separate assemblies; keep the installed combination intact when evaluating a spare.
Access sequence: EPS or SafeMove options can change access to the drive units by requiring axis-computer removal. Plan restoration of these displaced assemblies with the rectifier work.
Revision scope: The manual identifies the 3HAC14549-3 R3 base configuration. The complete /10A marking is preserved without assigning unsupported current, voltage or firmware characteristics to that suffix.
FAQ View All FAQ
-
Why must the drive-system generation be identified before replacing 3HAC14549-3/10A?Drive System 04 uses separate rectifier, capacitor and drive assemblies, whereas System 09 integrates the main functions differently. Identify the actual generation before selecting access, cabling and replacement procedures.
-
Can an R2 rectifier be treated as an equivalent of 3HAC14549-3/10A?The documented R2 and R3 arrangements use different capacitor selections. Compare the installed rectifier/capacitor/main-drive combination and complete unit marking rather than accepting a replacement from the shared DSQC family name.
-
Does the C3 capacitor reference mean it is supplied with 3HAC14549-3/10A?No. It identifies the companion assembly in the documented R3 configuration. Confirm the offered physical scope separately; the rectifier reference does not include the capacitor, servo drives or cabinet wiring.
-
How can EPS or SafeMove change access to 3HAC14549-3/10A?For the documented System 04 repair, these installed options can require removal of the axis-computer unit before access to the drive components. Use the actual option-specific procedure and retain a record of all disturbed connections.
-
Where should 3HAC14549-3/10A be located in a Dual Cabinet Controller?The System 04 repair description places the servo-drive power components in the Drive Module for the dual-cabinet arrangement. Match the cabinet layout and circuit diagram rather than applying a single-cabinet physical location blindly.
-
What must be restored around 3HAC14549-3/10A after refitting?Restore the intended mounting orientation, attachment, inter-unit busbars and disconnected connectors, then refit an axis-computer assembly if it was removed. Prove the restored controller configuration before machine release.
-
Does the /10A portion of 3HAC14549-3/10A establish a 10 A output rating?It remains part of the supplied unit marking. The available base-configuration evidence does not define it as a 10 A electrical rating, so circuit selection must use the delivered rating information and applicable cabinet documentation.
-
Why is switching off the robot mains insufficient by itself before servicing 3HAC14549-3/10A?The cabinet can retain DC-link energy and external connected circuits can remain live. Apply the applicable isolation and stored-energy verification procedure to the actual power section before disconnecting busbars or connectors.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.