Speak to a sourcing specialist
sales13@apterpower.com

3HAC14549-3/10A

Robot Controller Rectifier Unit
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

This rectifier belongs to the IRC5 robot-controller drive-power arrangement. Its R3 base assembly is selected with the associated capacitor and servo-drive configuration, while the supplied /10A marking remains part of the complete unit identity.
  • Manufacturer part number
    3HAC14549-3/10A
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    12.7cm x 14.5cm x 14.2cm
  • Country of Origin
    Sweden
Get a quick price for 3HAC14549-3/10A
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.
  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.
  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.
  • Match the complete marking

    Include 3HAC14549-3/10A with the complete /10A suffix and installed IRC5 drive-system identification. Keep the exact reference on your enquiry and quotation.
  • Check the offered item before ordering

    Request available rectifier-label, connector and busbar-interface photos. Have your maintenance team compare the offered 3HAC14549-3/10A with the installed equipment and applicable ABB documentation.

Technical specifications for 3HAC14549-3/10A

  • Manufacturer:
    ABB
  • Product Category:
    Robot Systems
  • Spare Part Number:
    3HAC14549-3 / 10A
  • Weight:
    1.72 kg
  • Tariff Code:
    8537101190
  • Drive-system generation:
    04
  • Base rectifier designation:
    DSQC 618_R3
  • Configured drive position:
    Z2
  • Associated capacitor unit:
    DSQC 620_C3
  • Capacitor assembly reference:
    3HAC14551-2
  • Documented main-drive assembly:
    DSQC 617_3V3W
  • Main-drive reference:
    3HAC025338-006

Information

Overview Downloads Applications / Compatibility Product Precautions
  • IRC5 Drive System 04 distributes the rectifier, capacitor and axis-drive functions across separate components; the R3 assembly must be matched to that installed architecture.
System distinction: Drive System 04 has separate power components; the integrated Main Drive Unit architecture of Drive System 09 is a different replacement context.
R3 pairing: The R3 configuration is reviewed with its C3 capacitor arrangement, rather than borrowing the R2/C4 pairing.
Revision identity: Keep /10A with the offered rectifier reference; it is not used here as an electrical-current rating.
The offered 3HAC14549-3/10A retains the base R3 rectifier identity used in the documented IRC5 Drive System 04 arrangement. The R3 configuration pairs with a C3 capacitor unit, while the R2 arrangement uses a different capacitor selection. Comparing these assemblies as a set prevents a superficially similar rectifier from being accepted solely by connector appearance.

Drive System 04 and Drive System 09 both perform robot drive functions, but their power architectures differ. In System 04 the rectifier, capacitor and axis-drive components are separate; System 09 combines the main robot drive functions in a Main Drive Unit. Determine the installed generation before selecting a spare or planning external-axis work.

Rectifier replacement involves the cabinet power circuit, inter-unit busbars and the surrounding drive arrangement. Depending on the installed EPS or SafeMove option, the axis-computer assembly can affect removal access. Restore connectors, busbars, mounting orientation and any displaced assemblies using the actual cabinet circuit diagram and approved repair procedure.
Controller platform reference: IRC5 Drive System 04 R3 arrangement. Retain the R3/C3 configuration.
Prepare ABB 3HAC14549-3/10A using the approved machine documentation and site procedure.
Identify the drive generation

Confirm System 04 from the installed arrangement and controller documentation before selecting the repair procedure; System 09 unit instructions are not interchangeable.

Isolate all energy sources

Apply the IRC5 cabinet isolation and stored-energy procedure before disconnecting the rectifier or busbars. External equipment can remain energized after the robot mains are switched off.

Record the surrounding assemblies

Preserve the rectifier suffix, capacitor identity and main-drive configuration before dismantling the power section.

Plan option-board access

Check whether the installed EPS or SafeMove arrangement requires axis-computer removal for access, and retain all disturbed connections in the work record.

Restore the busbars correctly

Refit the rectifier in its intended orientation, reconnect inter-unit busbars and every disconnected connector before restoring displaced assemblies.

Prove the restored robot configuration

After approved reassembly, complete the controller-specific power-up and functional checks with the intended robot configuration; a mechanically fitted unit alone is not acceptance.

Alternative Names

ABB 3HAC14549-3/10A IRC5 Drive System 04 3HAC14549-3/10A

Technical notes

Power-section relationship: The System 04 rectifier, capacitor and servo-drive functions are separate assemblies; keep the installed combination intact when evaluating a spare.

Access sequence: EPS or SafeMove options can change access to the drive units by requiring axis-computer removal. Plan restoration of these displaced assemblies with the rectifier work.

Revision scope: The manual identifies the 3HAC14549-3 R3 base configuration. The complete /10A marking is preserved without assigning unsupported current, voltage or firmware characteristics to that suffix.

FAQ View All FAQ

  • Why must the drive-system generation be identified before replacing 3HAC14549-3/10A?
    Drive System 04 uses separate rectifier, capacitor and drive assemblies, whereas System 09 integrates the main functions differently. Identify the actual generation before selecting access, cabling and replacement procedures.
  • Can an R2 rectifier be treated as an equivalent of 3HAC14549-3/10A?
    The documented R2 and R3 arrangements use different capacitor selections. Compare the installed rectifier/capacitor/main-drive combination and complete unit marking rather than accepting a replacement from the shared DSQC family name.
  • Does the C3 capacitor reference mean it is supplied with 3HAC14549-3/10A?
    No. It identifies the companion assembly in the documented R3 configuration. Confirm the offered physical scope separately; the rectifier reference does not include the capacitor, servo drives or cabinet wiring.
  • How can EPS or SafeMove change access to 3HAC14549-3/10A?
    For the documented System 04 repair, these installed options can require removal of the axis-computer unit before access to the drive components. Use the actual option-specific procedure and retain a record of all disturbed connections.
  • Where should 3HAC14549-3/10A be located in a Dual Cabinet Controller?
    The System 04 repair description places the servo-drive power components in the Drive Module for the dual-cabinet arrangement. Match the cabinet layout and circuit diagram rather than applying a single-cabinet physical location blindly.
  • What must be restored around 3HAC14549-3/10A after refitting?
    Restore the intended mounting orientation, attachment, inter-unit busbars and disconnected connectors, then refit an axis-computer assembly if it was removed. Prove the restored controller configuration before machine release.
  • Does the /10A portion of 3HAC14549-3/10A establish a 10 A output rating?
    It remains part of the supplied unit marking. The available base-configuration evidence does not define it as a 10 A electrical rating, so circuit selection must use the delivered rating information and applicable cabinet documentation.
  • Why is switching off the robot mains insufficient by itself before servicing 3HAC14549-3/10A?
    The cabinet can retain DC-link energy and external connected circuits can remain live. Apply the applicable isolation and stored-energy verification procedure to the actual power section before disconnecting busbars or connectors.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.