Match the complete marking
Include PM5670-2ETH 1SAP151000R0278 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered PM5670-2ETH 1SAP151000R0278 reference with the installed equipment and applicable ABB documentation.
Technical specifications for PM5670-2ETH 1SAP151000R0278
-
Manufacturer:ABB
-
Product Category:PLC Systems
-
Spare Part Number:PM5670-2ETH 1SAP151000R0278
-
Weight:0.2 kg
-
Tariff Code:8537101190
-
Supply voltage:24 Vdc
-
Memory:160 MB
-
Minimum instruction time, bit:0.002 microseconds
-
Minimum instruction time, word:0.002 microseconds
-
Minimum instruction time, floating point:0.002 microseconds
-
Ethernet interfaces:2
-
Serial interface:RS-232/RS-485
-
CAN interface:Integrated
-
Required terminal base:TB56xx-2ETH
-
Published product weight:0.133 kg
-
Revision status:R0278 revision 2; Limited / Classic
-
Successor revision:1SAP151000R0378 revision 3
Information
- The R0278 module combines the AC500 application processor with onboard Ethernet, serial and CAN interfaces for compact control stations.
Integrated interfaces: Two Ethernet ports plus RS-232/RS-485 and CAN
Hardware boundary: R0278 revision 2 requires the TB56xx-2ETH terminal base and a revision-compatible AC500 project
R0278 identifies revision 2 hardware. ABB lists the feature-compatible R0378 revision 3, but revision 3 requires CPU firmware 3.6.0 or later and is not a blind swap for an older project.
The PM5670-2ETH processor mounts on the TB56xx-2ETH terminal base. Inspect the base contacts, retained wiring and stored application before removing the CPU.
-
ABB PM5670-2ETH 1SAP151000R0278 technical reference
R0278 processor resources, integrated interfaces, TB56xx-2ETH relationship and documented revision boundary. -
ABB PM5670-2ETH 1SAP151000R0278 engineering guide
Backup, base inspection, dual-Ethernet recovery, serial/CAN checks and task/I/O acceptance for an AC500 exchange.
Platform applications: The uses below require the documented ABB AC500 controller station companion components and approved machine drawing.
-
AC500 machine control
Execute the retained IEC control application with the recorded task timing and I/O mapping. -
Dual-Ethernet controller node
Restore the two port roles, IP addresses and protocol settings from the commissioned project. -
Serial and CAN integration
Match the installed RS-232/RS-485 and CAN wiring, baud rate and protocol allocation. -
Revision-2 maintenance
Use R0278 where the approved installation and firmware record require the revision-2 processor.
Save the application, firmware, retain data and communication settings before removal.
Confirm TB56xx-2ETH identity and inspect its contacts before fitting the processor.
Do not load an R0278 archive into R0378 without checking the ABB firmware migration requirements.
Verify both Ethernet addresses and protocol assignments before reconnecting the plant network.
Confirm RS-485 polarity, termination and CAN topology from the installed drawing.
Compare CPU state, task execution and I/O response with the saved commissioning record.
Alternative Names
Technical notes
Revision control: Treat R0278 and R0378 as different hardware revisions even though ABB describes R0378 as feature-compatible.
Network record: Capture both MAC/IP roles and connected device names before exchange.
Acceptance record: Save firmware, project checksum, CPU status, task cycle and communication diagnostics.
FAQ View All FAQ
-
What must be preserved before exchanging PM5670-2ETH 1SAP151000R0278?Archive the application, firmware, retain data, both Ethernet roles, serial/CAN settings and I/O allocation so the replacement can be compared with the commissioned controller.
-
How should an R0378 migration be evaluated for PM5670-2ETH 1SAP151000R0278?Treat R0278 and R0378 as different hardware revisions; confirm CPU firmware 3.6.0 or later, terminal-base fit and project conversion before approving the published successor.
-
What should be inspected on the terminal base before fitting PM5670-2ETH 1SAP151000R0278?Verify TB56xx-2ETH identity, connector contacts, retained wiring and supply condition before the processor is seated.
-
How can network-address conflicts be prevented when PM5670-2ETH 1SAP151000R0278 is replaced?Record both MAC/IP roles and connected device names before removal, restore them offline where possible and reconnect each plant network only after duplicate-address checks.
-
Which communication paths should be proven after installing PM5670-2ETH 1SAP151000R0278?Prove both Ethernet links independently, then test the configured RS-232/RS-485 and CAN paths using the original device and baud settings.
-
How should task behavior be compared after restoring PM5670-2ETH 1SAP151000R0278?Record firmware, project checksum, CPU state and task-cycle values, then compare mapped I/O response with the saved commissioning record.
-
What should be checked if PM5670-2ETH 1SAP151000R0278 starts but field I/O remains unavailable?Check the terminal-base identity, loaded project, firmware compatibility and I/O allocation before changing field wiring or replacing another module.
-
Which evidence closes the replacement of PM5670-2ETH 1SAP151000R0278?Retain CPU diagnostics, task timing, both Ethernet results, serial/CAN tests and selected I/O proofs as the as-left record.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.