-
Match the complete marking
Send the complete CM592-DP 1SAP173200R0001 marking, all revision labels, current-unit photographs and installed position.
-
Check the offered item before ordering
Compare the offered CM592-DP 1SAP173200R0001 interfaces, revision and included items with the approved system record before ordering.
Technical specifications for CM592-DP 1SAP173200R0001
-
Manufacturer:ABB
-
Product Category:PLC Systems
-
Spare Part Number:CM592-DP 1SAP173200R0001
-
Weight:0.1 kg
-
Tariff Code:8537101190
-
Product type:AC500 PROFIBUS DP Master Communication Module
-
System platform:ABB AC500 PLC
-
Type designation:CM592-DP
-
Order code:1SAP173200R0001
-
Protocol:PROFIBUS DP V0/V1
-
Network role:Master
-
Physical connection:9-pin D-Sub
-
PLC platform:AC500
-
Remote I/O support:S500 and S500-eCo families as documented
-
Hot-swap I/O context:S500 I/O application
-
Manufacturer catalog weight:0.092 kg
-
Module class:Communication module
-
Selection boundary:CPU compatibility, project and bus parameters
-
Replacement basis:Complete marking and installed-system evidence
Information
- ABB CM592-DP 1SAP173200R0001 is a ac500 profibus dp master communication module documented for ABB AC500 PLC.
Nine-pin bus interface: Connector, shield, termination and segment layout follow the installed PROFIBUS design.
Project-held station map: Slave addresses, GSD data, diagnostics and cycle settings are restored from the approved AC500 project.
Compatibility depends on the installed AC500 CPU, firmware, project version and remote-I/O arrangement. The module is not equivalent to the CM582-DP slave execution.
Before replacement, export the controller project and bus configuration. After fitting, confirm master startup, slave recognition, diagnostic state and representative I/O transfer.
CM592-DP 1SAP173200R0001 Technical Reference
ABB PLC Automation Main Catalog, communication-module ordering data. Verified identifiers, ratings and evidence boundaries applicable to CM592-DP 1SAP173200R0001.CM592-DP 1SAP173200R0001 Installation & Verification Guide
Product-specific field guide for identity capture, controlled exchange, commissioning evidence and handover.
Application scope: Use CM592-DP 1SAP173200R0001 only where the product identity, revision, configuration and approved system documentation agree.
PROFIBUS DP master control
Coordinate documented remote I/O and field devices from an AC500 CPU.S500 remote I/O
Support the approved PROFIBUS remote-I/O arrangement.Fieldbus diagnostics
Use master and slave diagnostics to locate addressing, cable and device faults.AC500 retrofit service
Retain CPU compatibility, project, GSD files and bus timing.
Match CM592-DP and 1SAP173200R0001, not the slave variant.
Retain GSD files, slave map, addresses and diagnostics.
Check pinning, shield bonding and termination.
Match CPU, firmware and supported module arrangement.
Confirm each address reaches data exchange before enabling outputs.
Save final master and slave status with representative I/O results.
Alternative Names
Technical notes
Exact identity: CM592-DP 1SAP173200R0001
Documented function: AC500 PROFIBUS DP Master Communication Module
Technical evidence: ABB PLC Automation Main Catalog, communication-module ordering data
Verification boundary: Confirm the complete marking and installed ABB AC500 PLC arrangement before selection
FAQ View All FAQ
-
How is the master role of CM592-DP 1SAP173200R0001 distinguished from a PROFIBUS slave module?Confirm the CM592-DP type and 1SAP173200R0001 order code; do not substitute the CM582-DP slave execution.
-
Which AC500 compatibility checks are required for CM592-DP 1SAP173200R0001?Verify the installed CPU, firmware, engineering project and supported communication-module arrangement before fitting the module.
-
How should GSD and station data be managed for CM592-DP 1SAP173200R0001?Retain the approved device descriptions, slave addresses, module configuration and diagnostic mapping in the AC500 project.
-
What DP V0/V1 functions should be checked after installing CM592-DP 1SAP173200R0001?Verify cyclic data exchange first, then confirm any configured parameterization, diagnostics or acyclic services used by the project.
-
How should baud rate and station addressing be verified for CM592-DP 1SAP173200R0001?Compare the project settings with the installed segment and every slave before enabling field outputs.
-
What connector checks apply to the 9-pin interface on CM592-DP 1SAP173200R0001?Inspect pin assignment, shield bonding, termination and segment continuity against the approved PROFIBUS installation.
-
How can a slave dropout be isolated when using CM592-DP 1SAP173200R0001?Review master diagnostics, identify the affected address, then separate cable, termination, slave power and configuration causes.
-
What proves successful commissioning of CM592-DP 1SAP173200R0001?All configured slaves must reach data exchange with expected diagnostics and representative I/O must match the controller project.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.









