Speak to a sourcing specialist
sales13@apterpower.com

CBHX165C 5R 414

DC-Bus Charging Resistor
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

ABB CBHX165C 5R 414 is a 5-ohm DC-bus charging resistor used in the precharge path of documented ACS800-104 drive assemblies.
  • Manufacturer part number
    CBHX165C 5R 414
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    16.5cm x 6cm x 3.2cm
  • Country of Origin
    Sweden
Get a quick price for CBHX165C 5R 414
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete CBHX165C 5R 414 marking with global commercial alias, product ID, current-unit photographs and required quantity.
  • 1

    Confirm the offer

    For CBHX165C 5R 414, confirm documented function, resistance per resistor, included items and the documented ABB ACS800-104 drive charging circuits fit.
  • 2

    Arrange dispatch

    Approve the CBHX165C 5R 414 quantity after checking drive family; record the agreed dispatch date and delivery details.
  • Match the complete marking

    Send the complete CBHX165C 5R 414 marking, revision labels, current-unit photographs and installed position.

  • Check the offered item before ordering

    Compare the offered CBHX165C 5R 414 interfaces, ratings and included items with the approved system record before ordering.

Technical specifications for CBHX165C 5R 414

  • Manufacturer:
    ABB
  • Product Category:
    General Automation
  • Spare Part Number:
    CBHX165C 5R 414
  • Weight:
    0.45 kg
  • Tariff Code:
    8537101190
  • Product type:
    DC-Bus Charging Resistor
  • System platform:
    ABB ACS800-104 drive charging circuits
  • Product ID:
    64803689
  • Documented function:
    Charging resistor
  • Resistance per resistor:
    5.00 ohm
  • Drive family:
    ACS800-104
  • Circuit position:
    DC-bus precharge path
  • Quantity dependency:
    Drive type and voltage class
  • Parallel-equivalent examples:
    2.50, 1.67, 1.25, 1.00 or 0.83 ohm using multiple units
  • Replacement boundary:
    Resistor quantity and charging-circuit design

Information

Overview Downloads Applications / Compatibility Product Precautions
  • CBHX165C 5R 414 limits inrush current while the ACS800-104 DC link charges, after which the approved bypass path carries normal operation.
Precharge-current control: The resistor limits DC-link capacitor charging current before the main charging bypass closes.
Modular resistance scaling: ABB obtains lower equivalent resistance by fitting multiple 5-ohm units in documented converter sizes.
Drive-specific quantity: The correct number is selected from the exact ACS800-104 voltage and power table.
ABB identifies CBHX 165 C 5R 414, product ID 64803689, as a 5-ohm charging resistor used in ACS800-104 charging circuits.

Depending on the converter voltage and power, ABB uses one or more units to obtain the documented equivalent resistance. The model alone does not define the correct quantity for a cabinet.

Service includes isolating and discharging the DC link, checking the charging contactor and fuses, inspecting heat damage and measuring each resistor before restoring the precharge sequence.
Controller platform reference: ABB ACS800-104 charging circuit. Follow approved ABB instructions.
References for CBHX165C 5R 414 cover dC-Bus Charging Resistor, its ABB ACS800-104 drive charging circuits relationship and a separate field-verification procedure.
Use the technical reference for resistance per resistor and drive family; use the field guide to retain installation and commissioning records.
System fit: CBHX165C 5R 414 belongs in an ACS800-104 precharge circuit whose installed resistor quantity determines the effective charging resistance.

Selection impact: Replacement selection must preserve the 5-ohm element value, physical mounting, thermal clearance and connection to the charging contactor, fuses and DC-link capacitors.
Before servicing CBHX165C 5R 414, discharge the DC link, count installed units and preserve its ABB ACS800-104 drive charging circuits relationship.
Discharge the DC link

Prove zero hazardous voltage before service.

Count installed units

Record quantity and resulting circuit resistance.

Check the charging path

Inspect fuses, contactor, resistor wiring and capacitors.

Measure each resistor

Compare resistance and insulation with the approved design.

Restore thermal clearance

Preserve mounting and separation from sensitive parts.

Observe precharge

Verify DC-link rise and bypass timing.

Alternative Names

ABB CBHX165C 5R 414 DC-Bus Charging Resistor CBHX165C 5R 414

Technical notes

Exact identity: CBHX165C 5R 414

Documented function: DC-Bus Charging Resistor

Technical evidence: ABB ACS800-104 Hardware Manual charging-circuit tables, product ID 64803689

Evidence boundary: Only the documented ABB ACS800-104 drive charging circuits relationship and stated exact-model values are applied

Commissioning record: Retain installed markings, configuration and functional proof

FAQ View All FAQ

  • What resistance is assigned to one CBHX165C 5R 414 unit?
    ABB documents 5.00 ohms per CBHX 165 C 5R 414 resistor.
  • Why can the quantity of CBHX165C 5R 414 vary between drives?
    ABB connects multiple units in some ACS800-104 ratings to achieve a lower equivalent charging resistance.
  • Which cabinet information is needed before ordering CBHX165C 5R 414?
    Provide the full ACS800-104 type code, voltage class, charging-circuit drawing and installed resistor quantity.
  • What must be discharged before servicing CBHX165C 5R 414?
    Follow the approved drive isolation procedure and prove the DC link has discharged to a safe level.
  • Which companion devices should be checked after a failed CBHX165C 5R 414?
    Inspect the charging fuses, bypass contactor, control circuit, DC-link capacitors and resistor wiring.
  • How should CBHX165C 5R 414 be measured before installation?
    Use an approved low-resistance method and compare each unit with its marking and the cabinet design.
  • What thermal inspection applies to CBHX165C 5R 414?
    Check enclosure discoloration, cracked insulation, loose leads and clearance from heat-sensitive components.
  • Which DC-link charging sequence confirms CBHX165C 5R 414 is operating correctly?
    Measure the controlled DC-link rise, verify the bypass transition at the approved threshold and confirm that CBHX165C 5R 414 does not remain energized or overheat after precharge.