Match the complete marking
Send the complete CBHX165C 5R 414 marking, revision labels, current-unit photographs and installed position.
-
Check the offered item before ordering
Compare the offered CBHX165C 5R 414 interfaces, ratings and included items with the approved system record before ordering.
Technical specifications for CBHX165C 5R 414
-
Manufacturer:ABB
-
Product Category:General Automation
-
Spare Part Number:CBHX165C 5R 414
-
Weight:0.45 kg
-
Tariff Code:8537101190
-
Product type:DC-Bus Charging Resistor
-
System platform:ABB ACS800-104 drive charging circuits
-
Product ID:64803689
-
Documented function:Charging resistor
-
Resistance per resistor:5.00 ohm
-
Drive family:ACS800-104
-
Circuit position:DC-bus precharge path
-
Quantity dependency:Drive type and voltage class
-
Parallel-equivalent examples:2.50, 1.67, 1.25, 1.00 or 0.83 ohm using multiple units
-
Replacement boundary:Resistor quantity and charging-circuit design
Information
- CBHX165C 5R 414 limits inrush current while the ACS800-104 DC link charges, after which the approved bypass path carries normal operation.
Modular resistance scaling: ABB obtains lower equivalent resistance by fitting multiple 5-ohm units in documented converter sizes.
Drive-specific quantity: The correct number is selected from the exact ACS800-104 voltage and power table.
Depending on the converter voltage and power, ABB uses one or more units to obtain the documented equivalent resistance. The model alone does not define the correct quantity for a cabinet.
Service includes isolating and discharging the DC link, checking the charging contactor and fuses, inspecting heat damage and measuring each resistor before restoring the precharge sequence.
CBHX165C 5R 414 Technical Reference
ABB ACS800-104 Hardware Manual charging-circuit tables, product ID 64803689. Use it to confirm global commercial alias, product ID and documented function for the offered item.CBHX165C 5R 414 Installation & Verification Guide
Field guide for discharge the DC link, count installed units and check the charging path during CBHX165C 5R 414 exchange.
Selection impact: Replacement selection must preserve the 5-ohm element value, physical mounting, thermal clearance and connection to the charging contactor, fuses and DC-link capacitors.
ACS800 DC-link precharge
Limit capacitor inrush before the charging bypass closes.Parallel resistor assemblies
Build the documented equivalent resistance with the specified number of units.Charging-circuit fault diagnosis
Check resistor, fuses, contactor and control sequence as one path.Installed-base spare selection
Match product ID, resistor marking, quantity and drive type.
Prove zero hazardous voltage before service.
Record quantity and resulting circuit resistance.
Inspect fuses, contactor, resistor wiring and capacitors.
Compare resistance and insulation with the approved design.
Preserve mounting and separation from sensitive parts.
Verify DC-link rise and bypass timing.
Alternative Names
Technical notes
Exact identity: CBHX165C 5R 414
Documented function: DC-Bus Charging Resistor
Technical evidence: ABB ACS800-104 Hardware Manual charging-circuit tables, product ID 64803689
Evidence boundary: Only the documented ABB ACS800-104 drive charging circuits relationship and stated exact-model values are applied
Commissioning record: Retain installed markings, configuration and functional proof
FAQ View All FAQ
-
What resistance is assigned to one CBHX165C 5R 414 unit?ABB documents 5.00 ohms per CBHX 165 C 5R 414 resistor.
-
Why can the quantity of CBHX165C 5R 414 vary between drives?ABB connects multiple units in some ACS800-104 ratings to achieve a lower equivalent charging resistance.
-
Which cabinet information is needed before ordering CBHX165C 5R 414?Provide the full ACS800-104 type code, voltage class, charging-circuit drawing and installed resistor quantity.
-
What must be discharged before servicing CBHX165C 5R 414?Follow the approved drive isolation procedure and prove the DC link has discharged to a safe level.
-
Which companion devices should be checked after a failed CBHX165C 5R 414?Inspect the charging fuses, bypass contactor, control circuit, DC-link capacitors and resistor wiring.
-
How should CBHX165C 5R 414 be measured before installation?Use an approved low-resistance method and compare each unit with its marking and the cabinet design.
-
What thermal inspection applies to CBHX165C 5R 414?Check enclosure discoloration, cracked insulation, loose leads and clearance from heat-sensitive components.
-
Which DC-link charging sequence confirms CBHX165C 5R 414 is operating correctly?Measure the controlled DC-link rise, verify the bypass transition at the approved threshold and confirm that CBHX165C 5R 414 does not remain energized or overheat after precharge.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.