Technical specifications for A50-30-11 1SBL351001R8011
-
Manufacturer:ABB
-
Product Category:General Automation
-
Spare Part Number:A50-30-11 1SBL351001R8011
-
Weight:1.2 kg
-
Tariff Code:8537101190
-
Product type:Three-Pole AC-Operated Contactor
-
System platform:ABB A50 contactor and motor-control assemblies
-
Main poles:3
-
Control circuit:AC operated
-
Rated operational power at 400 V AC-3:22 kW
-
Rated AC-1 current at 40 °C:100 A
-
UL/CSA motor rating at 480 V:40 hp
-
General-use rating at 600 V AC:80 A
-
Control voltage at 50 Hz:220–230 V AC
-
Control voltage at 60 Hz:230–240 V AC
-
Fitted auxiliary contacts:1 NO + 1 NC
Information
- ABB A50-30-11 1SBL351001R8011 combines three main poles, 1 NO + 1 NC auxiliary contacts and the R8011 AC coil execution in one motor-control contactor.
Order-code defined coil: R8011 selects the 220–230 V 50 Hz / 230–240 V 60 Hz control-voltage execution.
Built-in control feedback: One normally open and one normally closed auxiliary contact are fitted to the exact type.
ABB catalogs the A50 execution at 22 kW for 400 V AC-3 duty and 100 A for AC-1 duty at 40 °C. Application selection still depends on utilization category, switching frequency, enclosure temperature and short-circuit coordination.
Before exchange, record the coil supply, main and auxiliary wiring, overload arrangement and mechanical accessories. Commission with the load controlled and prove pick-up, drop-out, phase continuity and auxiliary-contact feedback.
A50-30-11 1SBL351001R8011 Technical Reference
ABB Motor Protection and Control main catalog, order code 1SBL351001R8011. Use it to confirm ABB order code, contactor type and main poles for the offered item.A50-30-11 1SBL351001R8011 Installation & Verification Guide
Field guide for prove coil voltage, map all poles and check coordination during A50-30-11 1SBL351001R8011 exchange.
Selection impact: The R8011 coil code and auxiliary-contact arrangement affect control-circuit compatibility; verify the 50/60 Hz coil voltage, overload coordination and terminal plan before replacement.
Three-phase motor switching
Apply the documented AC-3 rating after checking motor duty and starts per hour.Power-circuit control
Use the AC-1 rating only under the catalog temperature and utilization conditions.Panel contactor replacement
Preserve coil voltage, auxiliary contacts, accessories and terminal wiring.Motor-starter maintenance
Coordinate the contactor with overload and short-circuit protection.
Confirm the R8011 50/60 Hz supply.
Label three main poles and both auxiliary contacts.
Retain overload and short-circuit protective devices.
Apply approved terminal values and inspections.
Verify pickup, drop-out and auxiliary feedback.
Check phase current and interlocks under controlled load.
Alternative Names
Technical notes
Exact identity: A50-30-11 1SBL351001R8011
Documented function: Three-Pole AC-Operated Contactor
Technical evidence: ABB Motor Protection and Control main catalog, order code 1SBL351001R8011
Evidence boundary: Only the documented ABB A50 contactor and motor-control assemblies relationship and stated exact-model values are applied
Commissioning record: Retain installed markings, configuration and functional proof
FAQ View All FAQ
-
Which coil voltage is built into A50-30-11 1SBL351001R8011?Order suffix R8011 specifies 220–230 V AC at 50 Hz and 230–240 V AC at 60 Hz.
-
What motor rating applies to A50-30-11 1SBL351001R8011 at 400 V?ABB lists 22 kW at 400 V for AC-3 duty under the catalog conditions.
-
How does the AC-1 rating of A50-30-11 1SBL351001R8011 differ from the AC-3 rating?AC-1 is a current rating for non-inductive or slightly inductive loads; AC-3 is the motor-duty operating-power rating.
-
Which auxiliary contacts are fitted to A50-30-11 1SBL351001R8011?The exact A50-30-11 execution includes one normally open and one normally closed auxiliary contact.
-
What should be checked before transferring wiring to A50-30-11 1SBL351001R8011?Record all three main poles, coil terminals, auxiliary contacts, overload links and any front or side accessories.
-
How should the short-circuit protection for A50-30-11 1SBL351001R8011 be verified?Use the approved ABB coordination table for the actual supply, prospective current, overload relay and protective device.
-
What mechanical checks follow installation of A50-30-11 1SBL351001R8011?Verify mounting, terminal torque, unobstructed armature movement and correct contactor seating before energization.
-
What proves functional acceptance of A50-30-11 1SBL351001R8011?Confirm reliable pick-up and drop-out, balanced phase continuity, auxiliary feedback and motor current under controlled operation.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
A50-30-11 1SBL351001R8011Product Details -
63NHG00B-690 3ABD0001782Product Details -
RCM 230VAC 3C/0 3ABD00029943Product Details -
PM5670-2ETH 1SAP151000R0278Product Details -
F4332D 3HAC024322-001Product Details -
HITE303278R1Product Details -
CBHX165C 5R 414Product Details -
CM592-DP 1SAP173200R0001Product Details -
3HAC14549-3/10AProduct Details -
CI532V09 3BUP001190R1Product Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.