Technical specifications for 6ES7416-3XR05-0AB0
-
Manufacturer:Siemens
-
Product Category:PLC Systems
-
Spare Part Number:6ES7416-3XR05-0AB0
-
Weight:1.8519 lbs (0.84 kg)
-
Tariff Code:8537101190
-
Product type:CPU 416-3
-
System:SIMATIC S7-400
-
Work memory:11.2 MB: 5.6 MB code and 5.6 MB data
-
Integrated load memory:1 MB RAM
-
Load-memory expansion:Flash or RAM memory card; up to 64 MB
-
Interface 1:MPI/DP; up to 12 Mbit/s
-
Interface 2:PROFIBUS DP
-
Interface 3:Plug-in IFM module
-
Firmware reference:V5.3; match the installed firmware
-
Engineering software:STEP 7 V5.3 SP2 or higher with hardware update
-
Bit operation:30 ns typical
-
Floating-point operation:90 ns typical
-
S7 timers / counters:2048 / 2048
-
Power loss:5.5 W typical
-
Backplane current:1.1 A typical; 1.3 A maximum at 5 V DC
-
Slots required:2
Information
- Siemens 6ES7416-3XR05-0AB0. An installed CPU 416-3 configuration combines execution memory, load media and three interface positions; keep all three identities in the service record.
System: SIMATIC S7-400
Work memory: 11.2 MB: 5.6 MB code and 5.6 MB data
Integrated load memory: 1 MB RAM
The first interface is MPI/DP at up to 12 Mbit/s; the second is PROFIBUS DP and the third accepts a plug-in IFM module. Record the actual interface module and network settings. The reference firmware is V5.3, with STEP 7 V5.3 SP2 or later plus the corresponding hardware update.
Typical bit, word and fixed-point operations take 30 ns; floating-point operations take 90 ns. The CPU supports 2048 S7 timers and 2048 counters. It occupies two slots, draws up to 1.3 A from the 5 V backplane and has typical power loss of 5.5 W. Preserve the project, backup state and installed rack power budget.
-
Siemens 6ES7416-3XR05-0AB0 technical reference
Original manufacturer excerpt - PDF, 4 pages. CPU identity, memory, processing, rack configuration and interface characteristics. -
Siemens 6ES7416-3XR05-0AB0 installation guide
Prepared by Apter Power - PDF, 5 pages. Installed-system review, configuration checks, commissioning and handover.
Configuration scope: Technical values apply to the complete 6ES7416-3XR05-0AB0 execution. Retain the actual installed configuration and applicable Siemens instructions.
-
Controller replacement
Use the complete CPU 416-3 identity when preparing S7-400 service. Retain the project, hardware configuration and actual installed firmware as one replacement baseline. -
PROFIBUS system integration
Plan the MPI/DP and PROFIBUS DP connections against the installed network roles. Record any fitted IFM module separately from the CPU order identity. -
Load-media maintenance
Review RAM or Flash load media before a card change. Keep the loadable application image and the integrated code/data work-memory allocations distinct. -
Engineering baseline control
Coordinate the STEP 7 project and hardware update with the installed CPU firmware. Compare online diagnostics and configuration after restoring the approved application.
The CPU has 11.2 MB work memory: 5.6 MB for program code and 5.6 MB for data. The integrated work memory is not expandable.
There is 1 MB integrated RAM load memory. Supported RAM or Flash memory cards expand load memory up to 64 MB.
The first is MPI/DP up to 12 Mbit/s, the second is PROFIBUS DP and the third is a plug-in IFM module position. Verify which optional interface is actually fitted.
The reference is STEP 7 V5.3 SP2 or later with the corresponding hardware update. Match the actual installed firmware; the data-sheet reference is V5.3.
Bit, word and fixed-point operations are typically 30 ns, while floating-point operations are typically 90 ns.
It supports 2048 S7 timers and 2048 S7 counters. Retentivity settings remain part of the application configuration.
Alternative Names
Technical notes
System relationship: An installed CPU 416-3 configuration combines execution memory, load media and three interface positions; keep all three identities in the service record.
Configuration boundary: Two slots are required. Check the rack position, adjoining modules and the fitted interface module when preparing a replacement.
Technical reference: Siemens 6ES7416-3XR05-0AB0 Data Sheet. Technical values apply to the complete 6ES7416-3XR05-0AB0 execution. Retain the actual installed configuration and applicable Siemens instructions.
FAQ View All FAQ
-
How is work memory divided in 6ES7416-3XR05-0AB0?The CPU has 11.2 MB work memory: 5.6 MB for program code and 5.6 MB for data. The integrated work memory is not expandable.
-
Which load-memory options are available for 6ES7416-3XR05-0AB0?There is 1 MB integrated RAM load memory. Supported RAM or Flash memory cards expand load memory up to 64 MB.
-
What are the three interface positions on 6ES7416-3XR05-0AB0?The first is MPI/DP up to 12 Mbit/s, the second is PROFIBUS DP and the third is a plug-in IFM module position. Verify which optional interface is actually fitted.
-
Which STEP 7 baseline applies to 6ES7416-3XR05-0AB0?The reference is STEP 7 V5.3 SP2 or later with the corresponding hardware update. Match the actual installed firmware; the data-sheet reference is V5.3.
-
What processing times are typical for 6ES7416-3XR05-0AB0?Bit, word and fixed-point operations are typically 30 ns, while floating-point operations are typically 90 ns.
-
How many S7 timers and counters does 6ES7416-3XR05-0AB0 support?It supports 2048 S7 timers and 2048 S7 counters. Retentivity settings remain part of the application configuration.
-
What rack power demand must be considered for 6ES7416-3XR05-0AB0?The 5 V backplane current is 1.1 A typical and 1.3 A maximum; typical power loss is 5.5 W. Include the attached interface loads in the system assessment.
-
How many rack slots does 6ES7416-3XR05-0AB0 occupy?Two slots are required. Check the rack position, adjoining modules and the fitted interface module when preparing a replacement.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
6ES7416-3XR05-0AB0Product Details -
6ES7412-2XG00-0AB0Product Details -
8C-PAOHA1 51454469-275Product Details -
6SE7034-5HK84-1JC0Product Details -
6ES7952-1KM00-0AA0Product Details -
6ES7952-1AM00-0AA0Product Details -
C98043-A7011-L6Product Details -
6ES7365-0BA01-0AA0Product Details -
MC-TAOX12 51304335-125Product Details -
51402797-200 51305319-100Product Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.