Match the complete marking
Include 6ES7412-2XG00-0AB0 and any hardware revision or assembly markings visible on the item. Keep the complete reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label, connector and mounting photos. Have your maintenance team compare the offered 6ES7412-2XG00-0AB0 with the installed equipment and applicable Siemens documentation.
Technical specifications for 6ES7412-2XG00-0AB0
-
Manufacturer:Siemens
-
Product Category:PLC Systems
-
Spare Part Number:6ES7412-2XG00-0AB0
-
Weight:0.75 kg
-
Tariff Code:8537101190
-
Product series:SIMATIC S7-400
-
CPU designation:CPU 412-2
-
Program memory:72 KB
-
Data memory:72 KB
-
Working-memory expansion:Not expandable
-
Integrated load memory:256 KB RAM
-
Memory-card capacity:Up to 64 MB RAM or FLASH
-
Interface 1:MPI / PROFIBUS DP, isolated RS-485
-
Interface 2:PROFIBUS DP, isolated RS-485
-
Bus transmission rate:Up to 12 Mbit/s
-
S7 timers / counters:256 / 256
-
Power loss:7.5 W typical
Information
- The CPU 412-2 executes the S7 user program and exchanges process data with central and distributed I/O through the configured rack and bus connections.
Working memory: 72 KB program and 72 KB data
Communication: One MPI/DP interface and one DP interface
The processor has two isolated RS-485 interfaces. The first supports MPI or PROFIBUS DP and the second supports PROFIBUS DP. Both can operate at up to 12 Mbit/s, with master or slave operation determined by the project configuration. In master operation, the first interface supports up to 32 DP slaves and the second up to 64. The complete CPU may be configured as a DP slave only once, even though it has multiple interfaces.
The CPU supports STEP 7 programming, configurable process images and diagnostics for commissioning and fault investigation. The technical configuration with firmware V3.1 uses STEP 7 V5.2 or later, 256 S7 timers and 256 S7 counters. A battery-backed system preserves working and load memory; retentive behavior must be reviewed together with the installed backup arrangement and application startup settings.
-
Siemens 6ES7412-2XG00-0AB0 technical reference
Original Siemens technical excerpt - PDF, 3 pages. Product-specific technical information and applicable configuration details. -
Siemens 6ES7412-2XG00-0AB0 installation guide
Prepared by Apter Power - PDF, 5 pages. Model identification, interface checks, configuration review and commissioning verification.
Application scope: The following functions describe CPU integration tasks. Bus roles, cycle requirements and memory allocation must be established by the installed project.
-
Central automation
Execute the configured S7 logic using separate program and data working-memory areas. Check the application footprint against each 72 KB area. -
Distributed I/O
Use the configured PROFIBUS DP interfaces to communicate with distributed stations. Preserve slave addresses, data lengths and bus termination. -
Operator communication
Use MPI and supported S7 communication services for the programmed operator and engineering connections. Account for the available connection resources. -
Commissioning diagnostics
Use the diagnostic buffer, variable status and program-monitoring functions to investigate startup and communication faults in the installed application.
Match 6ES7412-2XG00-0AB0, firmware and rack configuration before replacing the CPU.
Back up the STEP 7 project and identify the installed memory card before changing hardware.
Retain the correct MPI/DP and DP configurations; the CPU may be configured as a DP slave only once.
Check the backup battery and startup settings before relying on retained process data.
Follow the S7-400 installation procedure and plant isolation requirements when removing or inserting hardware.
Check diagnostics, station communication and controlled outputs before returning the application to service.
Alternative Names
Technical notes
System relationship: Verify the rack power supply, module allocation and configured I/O addresses.
Applicability: The numerical CPU data describes the 6ES7412-2XG00-0AB0 configuration with firmware V3.1. Match installed firmware, memory card and STEP 7 project before replacement.
Technical reference: Siemens S7-400 CPU Data, A5E00165963-01; Siemens CPU 412-2 product information.
FAQ View All FAQ
-
How much working memory does 6ES7412-2XG00-0AB0 provide?It provides 72 KB for program code and 72 KB for data, totaling 144 KB. This working memory is not expandable.
-
Can the load memory of 6ES7412-2XG00-0AB0 be expanded?The integrated 256 KB RAM load memory supports compatible RAM or FLASH memory cards up to 64 MB.
-
Which communication interfaces are integrated in 6ES7412-2XG00-0AB0?The first interface supports MPI or PROFIBUS DP, and the second supports PROFIBUS DP. Both use isolated RS-485 connections.
-
What bus speed does 6ES7412-2XG00-0AB0 support?The MPI/DP and DP interfaces support rates up to 12 Mbit/s within a correctly configured bus installation.
-
How many DP slaves can 6ES7412-2XG00-0AB0 address?In master mode the first interface supports up to 32 DP slaves and the second up to 64, subject to the configured address and data limits.
-
Can both interfaces of 6ES7412-2XG00-0AB0 be configured as DP slaves?No. The CPU may be configured as a DP slave only once, even though it has more than one communication interface.
-
Which STEP 7 version applies to 6ES7412-2XG00-0AB0 with firmware V3.1?The firmware V3.1 technical configuration requires STEP 7 V5.2 or later. Match the actual installed firmware before project transfer.
-
How does 6ES7412-2XG00-0AB0 retain memory during a power interruption?Working and load memory are retained with the appropriate backup battery. Check the installed backup arrangement and configured retention settings.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
6ES7412-2XG00-0AB0Product Details -
8C-PAOHA1 51454469-275Product Details -
6SE7034-5HK84-1JC0Product Details -
6ES7952-1KM00-0AA0Product Details -
6ES7952-1AM00-0AA0Product Details -
C98043-A7011-L6Product Details -
6ES7365-0BA01-0AA0Product Details -
MC-TAOX12 51304335-125Product Details -
51402797-200 51305319-100Product Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.