6ES7417-4XL04-0AB0

Programmable Logic Controller Central Processing Unit
Siemens 6ES7417-4XL04-0AB0
Siemens 6ES7417-4XL04-0AB0
Siemens 6ES7417-4XL04-0AB0
Siemens 6ES7417-4XL04-0AB0
Siemens 6ES7417-4XL04-0AB0
Siemens 6ES7417-4XL04-0AB0
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Siemens 6ES7417-4XL04-0AB0 is a SIMATIC S7-400 CPU 417-4 with 20 MB work memory, integrated MPI/DP and DP interfaces, and two interface-module slots.
  • Manufacturer part number
    6ES7417-4XL04-0AB0
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    5cm x 21.7cm x 29cm
  • Country of Origin
    Germany
Get a quick price for 6ES7417-4XL04-0AB0
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete Siemens 6ES7417-4XL04-0AB0 reference, label photographs and required quantity.

  • 1

    Confirm the offer

    Review the offered revision, condition, included items and documents against the confirmed installation.

  • 2

    Arrange dispatch

    Confirm quantity, dispatch date, lead-time start and delivery details in the quotation.

  • Match the complete marking

    Provide the complete Siemens 6ES7417-4XL04-0AB0 marking.

  • Check the offered item before ordering

    Request available label and connector photos. Have your maintenance team compare the offered 6ES7417-4XL04-0AB0 with the installed equipment and applicable Siemens instructions.

Technical specifications for 6ES7417-4XL04-0AB0

  • Manufacturer:
    Siemens
  • Product Category:
    PLC Systems
  • Spare Part Number:
    6ES7417-4XL04-0AB0
  • Weight:
    1.06 kg
  • Tariff Code:
    8537101190
  • Code work memory:
    10 MB
  • Data work memory:
    10 MB
  • Bit operation time:
    0.03 µs
  • Floating-point operation time:
    0.09 µs
  • Timers / counters:
    2048 / 2048
  • Marker memory:
    16 KB
  • Integrated interfaces:
    1 MPI/DP and 1 DP
  • Interface-module slots:
    2, for compatible IF 964-DP modules
  • Maximum DP bit rate:
    12 Mbit/s
  • I/O address range:
    16 KB inputs and 16 KB outputs
  • S7 connection resources:
    64
  • Typical power loss:
    6 W

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Siemens 6ES7417-4XL04-0AB0 executes large S7-400 control programs while supporting distinct communication and distributed-I/O paths within the configured rack system.
Program execution: Process the configured control logic and associated runtime data.
Network coordination: Combine local control with configured distributed I/O and controller communications.
Project continuity: Hardware configuration, retained data and communication assignments govern replacement behavior.
The CPU executes the installed automation project with distinct resources for program code and runtime data. Project suitability therefore depends on more than a combined memory total.

Integrated network interfaces and fitted interface modules connect the controller to its configured distributed I/O and communication partners. The hardware configuration assigns the role of each connection.

The operating installation also depends on its startup and retained-data behavior. Restoring a controller includes recovering that commissioned state as well as the application blocks.
Controller platform reference: Siemens SIMATIC S7-400. Match the installed configuration and applicable instructions.
Siemens 6ES7417-4XL04-0AB0: original manufacturer technical information covering the specified interfaces and operating limits. Installation topics include: back up the commissioned cpu, inventory memory resources, identify optional dp modules, review startup and retention, inspect communication diagnostics.
Original manufacturer pages retain their technical context. Use the Apter Power guide with the applicable manufacturer instructions and approved installation design.
Prepare Siemens 6ES7417-4XL04-0AB0 for its configured installation using these checks.
Secure the controlled equipment

Establish the intended output states and process response before stopping or removing the CPU. Coordinate with operations and account for drives, remote stations and other controllers that depend on its communications.

Distinguish the integrated ports

Label MPI/DP and the second DP connection independently. Record network addresses, baud rates and master/slave roles, then compare them with the hardware configuration before restoring the bus connections.

Restore the rack configuration

Compare CPU position, rack type and any multiprocessor arrangement with the saved project. Resolve configuration differences before downloading or starting the application, including communication resources assigned to other modules.

Validate the I/O image

Compare configured addresses and process-image partitions with the actual remote and local I/O. Test representative signals and controlled outputs through the application to detect mapping errors before normal operation.

Release the verified project

Record the final program identity, interface assignments and functional-test results. Remove temporary forcing or commissioning overrides and obtain the required operating acceptance before returning the CPU to unattended control.

Inspect communication diagnostics

Review the diagnostic buffer and network status after controlled startup. Confirm programming-device, operator-panel and controller connections without exceeding the configured resource allocation.

Alternative Names

Siemens 6ES7417-4XL04-0AB0 6ES7417 4XL04 0AB0

Technical notes

Operating boundary: Memory, connection resources and process-image limits are separate design constraints.

Integration details: Match rack configuration, interface modules, firmware compatibility and the commissioned application.

FAQ View All FAQ

  • Why can a project exceed 6ES7417-4XL04-0AB0 capacity despite fitting its combined work-memory total?
    Code and data occupy separate work-memory areas. Check each partition independently; unused space in one does not automatically satisfy a shortage in the other.
  • How do load memory and work memory differ during a 6ES7417-4XL04-0AB0 replacement?
    The stored project and the executable runtime requirements are different checks. Retain the correct load-memory arrangement and confirm that the project's code and data fit the available work-memory partitions.
  • Can the bit-operation time of 6ES7417-4XL04-0AB0 predict the complete machine cycle?
    No. Program structure, other instruction types, communications and I/O processing contribute to the cycle. Assess the actual loaded application rather than multiplying only a bit-operation benchmark.
  • Why should HMI and engineering connections be included in the 6ES7417-4XL04-0AB0 connection budget?
    They consume communication resources alongside control connections. A project can run correctly in isolation yet lack resources when its normal operator and engineering clients reconnect.
  • What can go wrong if the two integrated ports on 6ES7417-4XL04-0AB0 are treated as interchangeable?
    The MPI/DP interface and the other DP interface can have different configured roles and addresses. Restore each cable to its assigned port and compare its network configuration.
  • Does an available interface slot on 6ES7417-4XL04-0AB0 mean an extra DP network is ready to use?
    No. The appropriate interface hardware and project configuration are required. Check what is actually fitted before assigning additional network connections.
  • Why should retentive data be reviewed separately from the program on 6ES7417-4XL04-0AB0?
    The correct program does not by itself establish the intended retained operating values. Restore and validate the required runtime state under the application's startup procedure.
  • How can correct CPU startup on 6ES7417-4XL04-0AB0 conceal an I/O mapping problem?
    The CPU may execute while addresses or process-image assignments differ from the installation. Compare representative field inputs and controlled outputs with the project before releasing the process.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.