Technical specifications for FCP270 P0917YZ
-
Manufacturer:Invensys
-
Product Category:DCS Systems
-
Spare Part Number:FCP270 P0917YZ
-
Weight:0.72 kg
-
Tariff Code:8537101190
-
Processor part:P0917YZ
-
Controller designation:FCP270
-
Control network interface:100 Mbps fiber-optic Ethernet
-
Fieldbus protocols:2 Mbps and 268 kbit/s HDLC
-
200 Series capacity:32 FBMs without FEM100; up to 128 with FEM100
-
100 Series capacity:Up to 64 FBMs
-
Mixed FBM capacity:Up to 64 modules total
-
Maximum control blocks:4,000
-
Maximum block execution:10,000 blocks/s
-
Minimum block cycle:50 ms
-
Input voltage:24 V DC typical, redundant
-
Power consumption:8.5 W maximum per module
-
Operating temperature:0 to +60 °C
-
Relative humidity:5–95%, non-condensing
-
Environmental class:ISA S71.04 Class G3
-
Redundancy:Fault-tolerant paired operation supported
Information
- Foxboro FCP270 P0917YZ is a field control processor that executes I/A Series control strategies and coordinates communication with connected fieldbus modules.
Fieldbus coordination: Exchanges process and diagnostic information with supported I/A Series fieldbus modules.
Redundant-controller capability: Can operate in the documented paired arrangement to support controller availability.
Use the verified technical rows below to screen the offer, then compare the installed drawing and manufacturer instructions. Processor part: P0917YZ; Controller designation: FCP270; Control network: I/A Series control network. These values do not authorize transferring specifications from a neighboring model.
During replacement, preserve the approved configuration and connection map. Perform a controlled visual, electrical and functional check, record the as-left result, and release the equipment only after the responsible site authority accepts the restored field control processor.
FCP270 P0917YZ Manufacturer Data Reference
Model-specific technical reference assembled from verified manufacturer-family records. PDF · 2 pages.FCP270 P0917YZ Installation & Verification Guide
Field guide covering identity capture, connection checks, controlled installation and acceptance evidence for FCP270 P0917YZ. PDF · 2 pages.
Application scope: Application suitability depends on the exact reference, hardware revision and installed configuration. Use site-approved drawings and manufacturer instructions for the final design decision.
Installed control-hardware service
Use FCP270 P0917YZ only in the compatible I/A Series control processor arrangement identified by the approved system documentation.Revision-controlled replacement
Preserve the installed identity, connector orientation and configuration while restoring the documented function.Controlled troubleshooting
Use recorded as-found values and approved tests to distinguish connection, companion-hardware and product faults.Lifecycle support
Keep the complete FCP270 P0917YZ reference and acceptance evidence with the asset record for future service.
Do not shorten FCP270 P0917YZ or transfer data from an adjacent reference.
Photograph connector orientation and label each cable or terminal before removal.
Retain the approved I/A Series control processor database, jumpers, switches or channel assignment as applicable.
Follow the site energy-isolation and ESD procedure before disturbing hardware.
Check the documented base, cable, terminal, power and partner-module relationship.
Complete visual, electrical and functional checks before return to automatic service.
Alternative Names
Technical notes
Evidence boundary: Technical rows apply to FCP270 P0917YZ or its explicitly identified manufacturer family context.
Compatibility: Physical fit does not establish electrical, firmware or system compatibility.
Commissioning: Use approved Foxboro instructions and site procedures for final installation and release.
FAQ View All FAQ
-
Which identity fields must match before installing FCP270 P0917YZ?Match the complete model, group, revision, connector layout and any programmed or option-specific devices with the installed record.
-
How should connector positions on FCP270 P0917YZ be documented?Photograph and label each connector before removal, then compare keyed positions and cable destinations against the approved drawing.
-
What configuration must be retained when replacing FCP270 P0917YZ?Retain switch or jumper positions, firmware or programmable-device identity and the system database or drive setup that governs the board.
-
How can a system fault be separated from a FCP270 P0917YZ board fault?Review diagnostics, power rails, connectors and companion hardware, then use an approved substitution or bench method without bypassing protection.
-
Why must the full revision of FCP270 P0917YZ be reviewed?Revision letters can reflect hardware or firmware compatibility boundaries; confirm interchangeability for the installed system before release.
-
What cleaning restrictions apply to FCP270 P0917YZ?Use an approved ESD-safe method, keep solvents away from labels and programmed devices, and do not disturb conformal coating or adjustments.
-
What controlled startup checks apply after fitting FCP270 P0917YZ?Verify supply rails, status indications, communication and the board-specific control function in the approved sequence before automatic operation.
-
What service evidence should be retained for FCP270 P0917YZ?Retain complete markings, revision, connector mapping, configuration records, diagnostic results and as-left functional acceptance.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.