Match the complete marking
Send the complete P0916WF marking, revision or option label, connector photographs and installed application details.
-
Check the offered item before ordering
Compare the offered P0916WF with the installed type 4 h/xlpe termination cable, termination hardware and approved Foxboro documentation before ordering.
Technical specifications for P0916WF
-
Manufacturer:Invensys
-
Product Category:DCS Systems
-
Spare Part Number:P0916WF
-
Weight:0.25 kg
-
Tariff Code:8537101190
-
Cable type:Type 4
-
Length:3 m
-
Insulation system:H/XLPE
-
Conductors:36 (18 pairs)
-
Conductor size:26 AWG
-
Nominal outside diameter:10.3 mm
-
Maximum outside diameter:10.7 mm
-
Temperature range:-40 to +90 °C
Information
- Foxboro P0916WF is the three-metre Type 4 H/XLPE termination cable for compatible paired-conductor I/A Series module connections.
Module-to-termination integrity: Keeps channel relationships fixed through the keyed cable assembly.
Environmental service construction: Uses the documented H/XLPE insulation system for the approved installation range.
Use the verified technical rows below to screen the offer, then compare the installed drawing and manufacturer instructions. Cable type: Type 4; Length: 3 m; Insulation system: H/XLPE. These values do not authorize transferring specifications from a neighboring model.
During replacement, preserve the approved configuration and connection map. Perform a controlled visual, electrical and functional check, record the as-left result, and release the equipment only after the responsible site authority accepts the restored type 4 h/xlpe termination cable.
P0916WF Manufacturer Data Reference
Model-specific technical reference assembled from verified manufacturer-family records. PDF · 2 pages.P0916WF Installation & Verification Guide
Field guide covering identity capture, connection checks, controlled installation and acceptance evidence for P0916WF. PDF · 2 pages.
Application scope: Application suitability depends on the exact reference, hardware revision and installed configuration. Use site-approved drawings and manufacturer instructions for the final design decision.
Module-to-termination connection
Use P0916WF only in the compatible I/A Series termination cable arrangement identified by the approved system documentation.Controlled cable replacement
Preserve the installed identity, connector orientation and configuration while restoring the documented function.Point-to-point restoration
Use recorded as-found values and approved tests to distinguish connection, companion-hardware and product faults.Spare-path verification
Keep the complete P0916WF reference and acceptance evidence with the asset record for future service.
Do not shorten P0916WF or transfer data from an adjacent reference.
Photograph connector orientation and label each cable or terminal before removal.
Retain the approved I/A Series termination cable database, jumpers, switches or channel assignment as applicable.
Follow the site energy-isolation and ESD procedure before disturbing hardware.
Check the documented base, cable, terminal, power and partner-module relationship.
Complete visual, electrical and functional checks before return to automatic service.
Alternative Names
Technical notes
Evidence boundary: Technical rows apply to P0916WF or its explicitly identified manufacturer family context.
Compatibility: Physical fit does not establish electrical, firmware or system compatibility.
Commissioning: Use approved Foxboro instructions and site procedures for final installation and release.
FAQ View All FAQ
-
How is the cable type of P0916WF verified before installation?Compare the complete part number, cable-type designation, connector keying and documented termination assembly. Cable length alone does not establish compatibility.
-
Why must the connector ends of P0916WF be photographed before removal?The photographs preserve orientation, keying, strain-relief position and module-to-termination association for an accurate replacement.
-
Can P0916WF be substituted by a cable with the same length?No. Match cable type, conductor arrangement, insulation system, connectors and approved module/termination pairing as well as length.
-
What bend and support checks apply to P0916WF?Maintain the documented bend radius, connector strain relief and routing separation; do not use the connector body to support cable weight.
-
How should continuity of P0916WF be checked?Use an approved de-energized point-to-point test against the installed drawing, without applying a test voltage that could damage connected electronics.
-
What does the insulation designation on P0916WF affect?It governs the applicable environmental and temperature service boundary; verify the installed location against the documented cable construction.
-
How should P0916WF be identified in the spare store?Record the complete part number, cable type, length, both connector ends and the associated module/termination assembly.
-
What commissioning evidence should be retained after fitting P0916WF?Retain continuity results, connector photographs, routing confirmation, channel checks and the updated as-left drawing reference.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.