Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for P0916AG
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for P0916AG

  • Manufacturer:
    Invensys
  • Product Category:
    DCS Systems
  • Spare Part Number:
    P0916AG
  • Estimated shipping dimensions:
    4.5x12.3x11.5cm
  • Weight:
    0.25 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Associated module:
    FBM204
  • Input channels:
    4 x 0-20 mA DC
  • Output channels:
    4 x 0-20 mA DC
  • Terminal style:
    Compression
  • Termination material:
    Polyamide
  • Termination cable type:
    Type 1
  • Cable length range:
    Up to 30 m
  • FBM cable connector:
    37-pin D-subminiature
  • TA cable connector:
    25-pin D-subminiature
  • Calibration:
    Not required for module and TA

Information

Overview Manuals Common Applications Product Precautions
Foxboro P0916AG connects an FBM204 mixed analog I/O module to eight isolated field channels through the documented Type 1 termination-cable arrangement.
  • FBM204 termination
  • 4 analog inputs
  • 4 analog outputs
  • Compression terminals

The assembly is selected with the FBM204, matching Type 1 cable and required certification. Channel polarity, shield treatment and loop-power design remain part of the controlled loop record.

Important Notice: RH916XK supersedes P0916AG and P0916XK, but any replacement still requires a termination, cable, certification and field-wiring review.

Foxboro P0916AG Manuals & Downloads
Foxboro P0916AG Technical Reference (PDF)Foxboro P0916AG Manufacturer Manual Excerpt (PDF)

The technical reference organizes exact characteristics and engineering boundaries. The manufacturer excerpt presents selected unchanged official pages used for exact-model review.

Mixed analog loop termination
Terminates four input and four output loops for FBM204.
FBM04 upgrade projects
Supports approved migration wiring through the documented adapter path.
Remote field wiring cabinets
Provides compression terminals away from the baseplate.
Like-for-like TA service
Restores the P0916AG terminal and cable identity without altering loop design.
Foxboro P0916AG installation checks: retain the exact identity, installed configuration and witnessed acceptance record throughout the work.
1
Confirm P0916AG and its FBM204 assignment.
2
Record all eight loop numbers, polarities and shield points.
3
Place analog loops in the approved manual or safe state.
4
Isolate field and loop power before removing conductors.
5
Label the Type 1 cable at both FBM and TA ends.
6
Inspect compression terminals for damage or loose strands.
7
Restore each input and output to the recorded channel.
8
Prove every 0-20 mA loop and control direction before release.

Technical notes

For P0916AG, retain the exact manufacturer identity, installed connection record and witnessed model-specific acceptance result.

FAQ View All FAQ

  • Which module is terminated by Foxboro P0916AG?
    It is a compression termination assembly for FBM204.
  • How many input loops connect through Foxboro P0916AG?
    It supports four 0-20 mA DC analog input channels.
  • How many output loops connect through Foxboro P0916AG?
    It supports four 0-20 mA DC analog output channels.
  • Which terminal style is used by Foxboro P0916AG?
    The assembly uses compression terminals.
  • Which cable type connects Foxboro P0916AG to FBM204?
    The manufacturer table specifies a Type 1 termination cable.
  • Which current part supersedes Foxboro P0916AG?
    RH916XK supersedes P0916AG and P0916XK.
  • Does Foxboro P0916AG require field calibration?
    The FBM204 specification states that calibration of the module and termination assembly is not required.
  • What completes commissioning of Foxboro P0916AG?
    Verify polarity and current on all four inputs and four outputs, then witness their correct control-system indications and actions.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.