Match the complete marking
Send the complete P0916NG marking, revision or option label, connector photographs and installed application details.
-
Check the offered item before ordering
Compare the offered P0916NG with the installed 16-channel relay output termination assembly, termination hardware and approved Foxboro documentation before ordering.
Technical specifications for P0916NG
-
Manufacturer:Invensys
-
Product Category:DCS Systems
-
Spare Part Number:P0916NG
-
Weight:0.25 kg
-
Tariff Code:8537101190
-
Output channels:16
-
Contact form:SPDT Form C
-
DC resistive rating:5 A below 30 V DC
-
125 V DC resistive rating:600 mA
-
125 V DC inductive rating:240 mA
-
AC contact rating:Up to 250 V AC, 5 A
-
Termination style:Compression terminals
-
Required cable family:Type 4
Information
- Foxboro P0916NG is the termination assembly for FBM242 discrete outputs, providing sixteen externally powered relay-output channels through Form C contacts.
Mixed-load application support: Accommodates documented AC and DC switching duties within the published contact limits.
Channel-by-channel field termination: Provides a defined terminal position for each commanded output circuit.
Use the verified technical rows below to screen the offer, then compare the installed drawing and manufacturer instructions. Output channels: 16; Contact form: SPDT Form C; DC resistive rating: 5 A below 30 V DC. These values do not authorize transferring specifications from a neighboring model.
During replacement, preserve the approved configuration and connection map. Perform a controlled visual, electrical and functional check, record the as-left result, and release the equipment only after the responsible site authority accepts the restored 16-channel relay output termination assembly.
P0916NG Manufacturer Data Reference
Model-specific technical reference assembled from verified manufacturer-family records. PDF · 2 pages.P0916NG Installation & Verification Guide
Field guide covering identity capture, connection checks, controlled installation and acceptance evidence for P0916NG. PDF · 2 pages.
Application scope: Application suitability depends on the exact reference, hardware revision and installed configuration. Use site-approved drawings and manufacturer instructions for the final design decision.
Signal and communication acquisition
Use P0916NG only in the compatible FBM242 discrete-output termination arrangement identified by the approved system documentation.Channel-map preservation
Preserve the installed identity, connector orientation and configuration while restoring the documented function.Diagnostic maintenance
Use recorded as-found values and approved tests to distinguish connection, companion-hardware and product faults.System commissioning
Keep the complete P0916NG reference and acceptance evidence with the asset record for future service.
Do not shorten P0916NG or transfer data from an adjacent reference.
Photograph connector orientation and label each cable or terminal before removal.
Retain the approved FBM242 discrete-output termination database, jumpers, switches or channel assignment as applicable.
Follow the site energy-isolation and ESD procedure before disturbing hardware.
Check the documented base, cable, terminal, power and partner-module relationship.
Complete visual, electrical and functional checks before return to automatic service.
Alternative Names
Technical notes
Evidence boundary: Technical rows apply to P0916NG or its explicitly identified manufacturer family context.
Compatibility: Physical fit does not establish electrical, firmware or system compatibility.
Commissioning: Use approved Foxboro instructions and site procedures for final installation and release.
FAQ View All FAQ
-
Which channel assignment must be preserved when replacing P0916NG?Record every terminal, channel, signal type and control-database point before removal, then verify the restored mapping point by point.
-
How is the termination hardware for P0916NG selected?Use the exact module specification and installed terminal assembly or cable type; connector fit alone is not proof of compatibility.
-
What live-value checks are useful for P0916NG?Compare raw input or output indication, engineering value, channel status and an independent field reference under a controlled condition.
-
How should isolation claims for P0916NG be applied?Apply only the isolation arrangement documented for this exact module and channel group; do not extend backplane isolation to field channels.
-
Which configuration records should accompany P0916NG?Retain module address, channel configuration, scaling, alarm limits, communication parameters and the approved database revision.
-
How can a wiring fault be distinguished from a P0916NG hardware fault?Use channel status, terminal measurements, a known reference and controlled point substitution while preserving process protection.
-
What redundancy checks apply to P0916NG?Where supported, verify module roles, partner identity, communication health and an approved transfer test before returning to service.
-
What commissioning record should be retained for P0916NG?Keep channel-by-channel as-found/as-left results, communication status, configuration checksum or revision and acceptance signatures.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.