TC-308-02

Output module Smart Slot jumper cable

Product Describe:

Output module Smart 

Slot jumper cable

56-way LSZH wire harnesses

shrouded in Megamide Sleeving

Ask our team:

Get a quick price for: TC-308-02
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for TC-308-02

Technical specifications for TC-308-02

  • Manufacturer:
    ICS Triplex
  • Product Category:
    PLC Systems
  • Spare Part Number:
    TC-308-02
  • Estimated shipping dimensions:
    35x35x10cm
  • Weight:
    1.14 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • System Compatibility:
    Trusted TMR System
  • Standard Cable Length:
    2.5 Meters (8.2 Feet)
  • Operating Temp:
    -5°C to +60°C
  • Storage Temp:
    -25°C to +70°C
  • Safety Integrity Level:
    Certified for use in SIL 3 Safety Instrumented Systems (SIS)
  • Compliance:
    Certification ATEX / IECEx Zone 2 Hazardous Area approval

Information

Information

Overview Manuals Common Applications Product Precautions
The TC-308-02 is a dedicated Output Smart Slot Jumper Cable for the ICS Triplex Trusted system, used to enable redundant hot-standby connections for output modules. It is used to establish a physical connection between adjacent output slots to support the Smart Slot feature, allowing the replacement of faulty modules without interrupting the field actuator output.   
    • 56-Way High-Density Connectivity
    • Seamless Smart Slot Logic
    • 1500V DC Galvanic Isolation
This type of Trusted Communications Cable is designed to provide I/O connection between a faulty Trusted Digital Output module (40 Channel only) and the I/O module occupying the SmartSlot position in a Trusted Controller or Expander Chassis. The SmartSlot end of the cable (SKT1) is fitted with a 96-way type ‘C’ connector housed in a single-width hood. The hood is fitted with an earth braid. The faulty I/O module end is fitted with a 96-way type ‘R’ connector housed in a special-to-type plastic hood.

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. 
 ICS Triplex TC-308-02 Output module Smart Slot jumper cable Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Oil & Gas Refining
It ensures that safety isolation valves (XV) controlling burners or high-pressure reactors remain in their safe state during module replacement, preventing explosions caused by inadvertent trips.

Nuclear Power Generation
It guarantees that start-control signals for critical cooling pumps are not interrupted during controller maintenance, maintaining the heat removal capability of the reactor core.

Gas Turbine Power Plants
The TC-308-02 allows hot-swapping of faulty analog output modules without affecting the stability of the turbine speed.

LNG Storage & Transportation
It ensures that hydraulic solenoid valves controlling the emergency release of loading arms during LNG transfer do not fail due to a control module fault.

Semiconductor Abatement Systems
It ensures that control of dosing pumps and exhaust fans in abatement systems is not interrupted during module maintenance, preventing untreated toxic gas leaks.
 When using the TC-308-02 Output Smart Slot jumper cable, ensure it is installed between adjacent output slots logically paired as "Active" and "Standby," and strictly check the locking screws to prevent loose contacts caused by vibration. As it carries 56 critical output signals, you must strictly adhere to the minimum bend radius specifications and protect the Megamide reinforced sleeving from physical abrasion against cabinet edges. Before performing a hot-swap, verify the redundancy status is "Ready" in the software, strictly avoid plugging or unplugging without proper redundancy configuration to ensure the continuous integrity of the output loop at the SIL 3 level.

FAQS

  • How to correctly install the TC-308-02?
    It should be installed between the Field Termination Assemblies (FTA) on the rear of the chassis, connecting the corresponding interfaces of the main and standby modules, ensuring the locking screws are firmly secured.
  • Which modules is the TC-308-02 compatible with?
    It is specifically used with Output Modules of the Trusted system, such as the T8451 (Analog Output) or T8461 (Digital Output) modules.
  • What is the difference between TC-308-02 and TC-306-02?
    TC-306-02 is for input modules, while TC-308-02 is specifically for output modules. Their internal wiring logic and current/voltage characteristics are optimized for input and output signals, respectively.
  • What physical constraints should be noted when using the TC-308-02?
    The minimum bend radius must be observed to prevent internal cable cores from being damaged under long-term pressure or excessive bending, which could affect the integrity of the output loop.
  • How to determine if the TC-308-02 is functioning correctly?
    During system maintenance, observe the "Ready" or "Smart Slot" indicators on the module panel; if the LEDs are not lit, it usually means the jumper cable is poorly connected or the redundancy logic is not synchronized.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.