Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for TC-001-02-6M0
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for TC-001-02-6M0

  • Manufacturer:
    ICS Triplex
  • Product Category:
    PLC Systems
  • Spare Part Number:
    TC-001-02-6M0
  • Estimated shipping dimensions:
    35x35x10cm
  • Weight:
    1.14 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Conductor:
    Low voltage drop design
  • Connectors:
    Dedicated high-current multi-pin connector with mechanical locking device
  • Safety:
    SIL 3 certification system
  • Operating Voltage:
    20V DC to 32V DC
  • Redundancy:
    Power Feed A & B
  • Max Current Capacity:
    Approximately 40A (depending on specific load configuration and ambient temperature)
  • Operating Temperature:
    -5°C to +60°C
  • Storage Temperature:
    -25°C to +70°C
  • Humidity:
    5% - 95% Non-condensing

Information

Overview Manuals Common Applications Product Precautions
The TC-001-02-6M0  is a chassis power connection cable specifically designed for the ICS Triplex Trusted Triple Modular Redundant (TMR) system, with a length of 6 meters.   
    • Dual power supply
    • Optimized Inter-bay Connectivity
    • Provides extremely strong vibration resistance
The ICS Triplex is a triple-redundant (2-out-of-3) control platform that complies with the international functional safety standard IEC 61508. Its goal is to eliminate "single points of failure," ensuring that the system continues to operate even in the event of any hardware failure within the controller, thus protecting the safety of personnel, equipment, and the environment.Through a "two-out-of-three" voting logic, the system can seamlessly switch over and continue operating even if one processing channel fails, achieving zero downtime. All hardware and firmware are TUV certified, meeting the stringent requirements of Safety Integrity Level 3.

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. 
 ICS Triplex TC-001-02-6M0 Chassis Power Cable Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Petrochemical Refineries
It connects the main power distribution unit to expansion chassis in adjacent bays, ensuring stable redundant power for critical reactor monitoring systems.

Fuclear Power Plants
As the power transmission line for the TMR system, its high-spec flame-retardant design meets the strict cable integrity and high-availability requirements of nuclear plants.

LNG Terminals & Storage
It connects remote chassis via the 6m cable to monitor pressure during LNG unloading, preventing safety system failure due to power loss.

Urban Rail Power Hubs
Used for substation automation safety interlocking. It routes power from the DC distribution panel to safety PLC chassis, ensuring logical isolation of the rail power system during faults.

Offshore Oil & Gas Platforms
The 6m length allows inter-bay connection between power distribution and central control chassis, ensuring uninterrupted PLC power during extreme storms or fire emergencies.
 When using the TC-001-02-6M0 cable, strictly adhere to the minimum bend radius specifications to prevent internal core damage or increased voltage drop over its 6m length. During installation, ensure the mechanical locking screws at both connectors are fully tightened to prevent loose contacts caused by industrial vibration. Meanwhile, closely monitor the terminal voltage to ensure it remains within the required 24V DC range for redundant systems. Additionally, hot-swapping is strictly prohibited during operation, and the cable jacket should be inspected regularly for wear against cabinet edges to prevent short circuits.

FAQ View All FAQ

  • What is the primary use of the TC-001-02-6M0?
    Its primary use is to transmit 24V DC power from a power distribution unit (such as the T8292) to the control system's chassis.
  • What role does TC-001-02-6M0 play in a PLC system?
    It acts as the system's "lifeline," providing critical electrical power required for the PLC's processor and I/O modules to operate.
  • Which systems is the TC-001-02-6M0 compatible with?
    It is specifically compatible with the ICS Triplex Trusted T8000 series safety systems and is not for use with other brands of general-purpose PLCs.
  • Does the TC-001-02-6M0 product require special safety maintenance?
    Yes. As it involves a SIL 3 safety system, you should regularly check the cable jacket for wear and ensure there is no oxidation or overheating at the connectors.
  • Why choose the original TC-001-02-6M0 over general wires?
    The original cable undergoes strict flame-retardant and shielding tests to meet current load requirements and anti-interference standards in high-safety environments.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.