ICS Triplex TC-301-02-6M5 is an evidence-bounded Trusted low-smoke zero-halogen system cable. Rockwell Automation defines the TC-301-02 family for this exact system function and, where present, the xMx suffix as cable length to the nearest 0.5 m; TC-301-02-6M5 therefore denotes 6.5 m.
- Requested part number: TC-301-02-6M5
- Cable family: TC-301
- Insulation code: 02 = LSZH, flame retardant to IEC 60332-3 Cat A
- Cable length: 6.5 m
System role: Local expansion cable from a T8312 Expander Interface Adapter to a T8310 TMR Expander Processor. Only facts stated by the cited Rockwell Automation material are published; sibling, successor and third-party data are not transferred. Architecture boundary: Use only with the exact Trusted modules, adapters, FTA/VFTA, slot mode and connector arrangement documented for this cable family. Do not interchange cable families because input/output direction, local/remote expansion, number of ways, SmartSlot/Companion Slot, integral power and connector wiring differ. Before installation or replacement, verify the complete physical label, host equipment, companion hardware, wiring and approved commissioning procedure. Origin and HS code remain unpublished unless an exact manufacturer record or the physical package label establishes them.
Important Notice: Verify the complete ICS Triplex TC-301-02-6M5 physical label and installed-system documentation before use.
Apter Power TC-301-02-6M5 Manuals and Guides
Important Notice: The first link is the model-specific product-parameters PDF prepared only from the cited Rockwell Automation official evidence; the second link is the Apter Power product information manual. Confirm the physical nameplate, current Rockwell Automation documents, and host-system requirements before installation or replacement.
Installed-base maintenanceSupports evidence-led identification and replacement planning for ICS Triplex TC-301-02-6M5.
System documentationProvides a source-traceable boundary for the documented Trusted TC-301 cable architecture configuration.
Commissioning reviewGuides identity, companion-hardware, wiring and controlled functional checks before return to service.
Migration assessmentSeparates exact-model facts from successor, sibling and family-level information.
Read and follow the exact Rockwell Automation documentation and host-equipment instructions before work. Verify the complete physical nameplate and system configuration.
1Verify the complete ICS Triplex TC-301-02-6M5 label, revision and installed-system documentation before use.
2Do not interchange cable families because input/output direction, local/remote expansion, number of ways, SmartSlot/Companion Slot, integral power and connector wiring differ.
3De-energize the equipment and follow the site's approved electrical and process-safety procedure before disturbing hardware or wiring.
4Back up controller, drive, network and configuration data before replacement, migration or firmware work.
5Verify every companion module, cable, connector, termination and power source from approved drawings.
6Do not copy electrical, communication, mechanical or lifecycle values from a related model or successor.
7Perform a documented functional test and confirm diagnostics, alarms and fail-state behavior after work.
8Origin and HS code remain unpublished unless an exact manufacturer record or the physical package label establishes them.