SPHSS13

ABB SPHSS13 SPHSS13 Hydraulic Servo Module
In Stock
Ships by Friday, August 28
Fast Shipping Available

Product Describe:

ABB SPHSS13 is a hydraulic servo module.
Function: Hydraulic servo valve-position control.
Verify the exact nameplate, revision, host equipment, 
wiring and project configuration before use.

Ask our team:

Get a quick price for: SPHSS13
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for SPHSS13

Technical specifications for SPHSS13

  • Manufacturer:
    ABB
  • Product Category:
    DCS System
  • Spare Part Number:
    SPHSS13
  • Estimated shipping dimensions:
    3.5x31.5x17.5cm
  • Weight:
    0.28 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Sweden
  • Function:
    Hydraulic servo valve-position control
  • Operating power:
    +5 VDC ±5% at 576 mA typical; +15 VDC ±5% at 15 mA; -15 VDC ±5% at 12 mA; +24 VDC ±10% at 335 mA typical from termination unit
  • Power dissipation:
    2.88 W at +5 VDC; 0.23 W at +15 VDC; 0.18 W at -15 VDC; 8.04 W at +24 VDC, typical
  • LVDT secondary inputs:
    4 analog inputs total: 2 LVDT position inputs, each with 2 secondaries; 24 Vpp ±7 VDC common mode; 10 kohm differential input impedance
  • LVDT excitation outputs:
    2 analog primary excitation outputs; 400 Hz to 15 kHz
  • Servo outputs:
    2 protected analog outputs; opening or shorting one does not affect the other; servo mode ±300 mA
  • I/H modes:
    4-20 mA or 20-160 mA
  • Position/test outputs:
    One scaled position panel-meter output, one unscaled position feedback output, and one test-mode output
  • Digital inputs:
    3 optically isolated 250 VDC contact inputs: raise, lower, and trip bias
  • Digital output:
    1 independent optically isolated 250 VDC open-collector hard-manual output
  • Ambient temperature:
    0 to 70 °C
  • Dimensions:
    35.56 mm W x 177.80 mm H x 298.45 mm D

Information

Information

Overview Manuals Common Applications Product Precautions
ABB SPHSS13 is a Symphony Plus HR Series hydraulic servo module for closed-loop valve-position control. It allows an HR Series controller to drive a servo valve or I/H converter for manual or automatic control of a hydraulic actuator.
  • Function: Hydraulic servo valve-position control
  • Operating power: +5 VDC ±5% at 576 mA typical; +15 VDC ±5% at 15 mA; -15 VDC ±5% at 12 mA; +24 VDC ±10% at 335 mA typical from termination unit
  • Power dissipation: 2.88 W at +5 VDC; 0.23 W at +15 VDC; 0.18 W at -15 VDC; 8.04 W at +24 VDC, typical
  • LVDT secondary inputs: 4 analog inputs total: 2 LVDT position inputs, each with 2 secondaries; 24 Vpp ±7 VDC common mode; 10 kohm differential input impedance

The module accepts redundant LVDT position feedback and supports AC or DC LVDTs, then regulates redundant protected servo outputs in ±300 mA servo mode or 4-20 mA/20-160 mA I/H modes. It also provides LVDT excitation, scaled and unscaled position outputs, a test output, raise/lower/trip-bias contacts, and a hard-manual output. SPHSS13 works with NTHS03 termination and NKHS03 cable in ABB's documented evolution arrangement and commonly coordinates with SPTPS13 speed detection to form a turbine governor. Compatible HR controllers and exact firmware must be verified for the installed project. ABB lists steam-turbine throttle/control valves, gas-turbine fuel valves, inlet guide vanes, nozzle angle, hydro-turbine servo applications, and non-modulating valve-position reporting among its uses. ABB also documents SPHSS13 as the direct replacement platform for IMHSS03/04/05 and SPHSS03/04/05, but not as their alias or an automatic substitute.

Important Notice: Verify the full SPHSS13 nameplate/revision and installed function-code mode.

Apter Power SPHSS13 Manuals and Guides

Important Notice: The first link is the model-specific product-parameters PDF prepared only from the cited ABB official evidence; the second link is the Apter Power product information manual. Confirm the physical nameplate, current ABB documents, and host-system requirements before installation or replacement.

Steam-turbine valve positioning
Controls throttle, governor, and steam control-valve actuators with redundant LVDT feedback.
Gas-turbine fuel and guide-vane control
Regulates fuel valves, inlet guide vanes, and nozzle-angle actuators through servo or I/H outputs.
Hydro-turbine hydraulic servo control
Provides HR Series closed-loop positioning for approved hydraulic turbine actuator arrangements.
Non-modulating valve position indication
Reports open-close valve position without control, replacing SPLPS01 functionality in the ABB-documented use case.
Read and follow the exact ABB documentation and host-equipment instructions before work. Verify the complete physical nameplate and system configuration.
1
Treat hydraulic turbine control as critical equipment; use an approved outage, bypass, fail-safe, and rollback plan.
2
Back up Function Code 55 configuration, gains, limits, polarity, calibration, output mode, redundancy, and alarms before service.
3
Verify AC/DC LVDT type, excitation, wiring, secondaries, common mode, mechanical stroke, polarity, and calibration.
4
Confirm servo versus I/H mode, current range, coil/load limits, redundant-coil wiring, and hydraulic fail-safe direction before energizing.
5
Verify NTHS03, NKHS03, jumpers, dip switches, shields, field power, controller type, and required firmware against ABB/project documentation.
6
After service, test automatic calibration, raise/lower/trip bias, hard manual, both redundant outputs, LVDT feedback, alarms, tracking, and hydraulic travel under approved conditions.
7
Coordinate governor and overspeed testing with SPTPS13 or the installed speed system; SPHSS13 alone is not the speed-measurement module.
8
Do not treat the predecessor models as aliases or direct replacement as permission for an unreviewed hot swap.
9
Keep exact lifecycle phase, origin, HS code, and weight on HOLD without exact ABB evidence.

Alternative Names

Alternative Names

SPHSS13 ABB SPHSS13 SPHSS-13 SPHSS 13

Technical notes

Technical notes

Verify the full SPHSS13 nameplate/revision and installed function-code mode. Confirm AC/DC LVDT type, servo or I/H mode, coil current, termination NTHS03, cable NKHS03, controller firmware, and redundancy architecture. Do not merge SPHSS13 with IMHSS03/04/05, SPHSS03/04/05, SPLPS01, SPTPS13, or any service code. Treat direct replacement as an engineered migration requiring approved drawings, function-code review, calibration, and turbine testing.

FAQS

  • What is ABB SPHSS13?
    It is a Symphony Plus HR Series hydraulic servo valve-position control module.
  • What does it drive?
    A servo valve or I/H converter controlling a hydraulic actuator.
  • Which position sensors are supported?
    ABB documents AC or DC LVDTs with redundant position-feedback inputs.
  • What servo current is documented?
    Servo mode supports ±300 mA.
  • Which I/H ranges are documented?
    4-20 mA and 20-160 mA.
  • Does it have redundant outputs?
    Yes. ABB documents two protected servo outputs; opening or shorting one does not affect the other.
  • Which contact inputs are provided?
    Raise, lower, and trip bias.
  • Which termination hardware is documented?
    NTHS03 termination and NKHS03 cable in ABB's evolution material.
  • Which speed module commonly coordinates with it?
    SPTPS13 in typical turbine governor systems.
  • Can it report a non-modulating valve position?
    Yes. ABB documents position reporting without control and says this replaces prior SPLPS01 functionality.
  • Which controllers are documented in the evolution material?
    BRC300/400/410 with firmware M4 and HPC800 with firmware A_3.
  • What is the documented response time?
    ABB evolution material states less than 2 ms input-to-output.
  • Which heritage models does it replace?
    ABB states it directly replaces IMHSS03/04/05 and SPHSS03/04/05, subject to engineered verification.
  • Is SPHSS13 an alias of IMHSS03?
    No. It is a documented replacement platform with its own exact identity and specifications.
  • Are origin, HS code, weight, and formal lifecycle phase verified?
    No. Those fields remain HOLD without exact official evidence.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.