Product Describe:

General Electric DS200SDCCG1AGD DS215SDCCG1AZZ01A is identified as a drive control card assembly for the GE AC2000, DC2000 and EX2000 drive-control systems. Match the complete marking, board group and installed interface arrangement before replacement.
  • Manufacturer part number
    DS200SDCCG1AGD DS215SDCCG1AZZ01A
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    27.8cm × 21.2cm × 2.8cm
  • Country of Origin
    USA
Get a quick price for DS200SDCCG1AGD DS215SDCCG1AZZ01A
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete DS200SDCCG1AGD DS215SDCCG1AZZ01A marking, required quantity and installed drive context.

  • 1

    Confirm the offer

    Review the offered identity, condition, included items and delivery details.

  • 2

    Arrange dispatch

    Confirm the accepted quantity and destination in the quotation.

  • Match the complete marking

    Compare DS200SDCCG1AGD DS215SDCCG1AZZ01A with the installed board and applicable GE documentation.

  • Check the offered item before ordering

    Request photos of DS200SDCCG1AGD DS215SDCCG1AZZ01A; compare board marking, plugs, jumpers and included items with the installed unit.

Technical specifications for DS200SDCCG1AGD DS215SDCCG1AZZ01A

  • Manufacturer:
    General Electric
  • Product Category:
    Gas Turbine Control
  • Spare Part Number:
    DS200SDCCG1AGD DS215SDCCG1AZZ01A
  • Weight:
    0.54 kg
  • Tariff Code:
    8537101190
  • Board group:
    G1
  • Main processors:
    3
  • Drive Control Processor:
    80C186 at U1
  • Motor Control Processor:
    80C196 at U21
  • Co-motor Processor:
    TMS320C25 at U35
  • Documented plug connectors:
    8
  • Unused connector:
    9PL
  • Meter connector:
    11PL
  • Diagnostic LEDs:
    10
  • Slow fault-code range:
    1–399
  • Fast fault-code range:
    400–1023
  • DCP timing test point:
    720 Hz
  • Slow-background test point:
    90 Hz
  • MCP oscillator test point:
    8 MHz
  • Regulated logic test point:
    +5 V ±5%
  • Analog supply test points:
    +15 V and -15 V, each ±5%
  • Control-input maximum:
    ±24 V
  • Control-input impedance:
    27 kΩ
  • Reset noise filter:
    20 ms
  • Analog output no-load span:
    ±10 V
  • Analog output loaded span:
    ±8 V at 10 mA
  • Analog output series resistance:
    200 Ω
  • Feedback VCO gain jumper:
    JP7; 6:1
  • EEPROM write-protect jumper:
    JP1
  • Signal-mode jumper:
    JP8; bipolar or absolute
  • Installed memory devices:
    5
  • EPROM devices:
    4: U11, U12, U22 and U23
  • EEPROM devices:
    1: U9
  • Assembly suffix:
    DS215SDCCG1AZZ01A

Information

Overview Downloads Applications / Compatibility Product Precautions
  • DS200SDCCG1AGD DS215SDCCG1AZZ01A has a defined drive control card assembly role in the GE AC2000, DC2000 and EX2000 drive-control systems; selection depends on the complete board marking and installed execution.
Processor architecture: DCP, MCP and CMP form a three-processor control card.
Diagnostic boundary: 10 LEDs distinguish slow 1–399 and fast 400–1023 fault-code ranges.
Memory boundary: DS215 carries four EPROMs plus one EEPROM.
The complete DS200SDCCG1AGD DS215SDCCG1AZZ01A marking identifies the offered drive control card assembly. Record the removed board, host position and connected hardware so the comparison uses the actual installed boundary rather than a shortened family name.

Within the GE AC2000, DC2000 and EX2000 drive-control systems, evaluate this board together with its plugs, jumpers, connected power and feedback paths. Preserve the as-found interface map and revision evidence; a mechanically similar board is not automatically equivalent.

Commissioning should progress from identity and connection checks to controlled power-up, diagnostics and functional proof. Keep measured results, final status and open exceptions in the handover record.
Controller platform reference: GE AC2000, DC2000 and EX2000 drive-control systems. Use the applicable GE instruction and approved drive drawings for installation and commissioning.
The first document provides the applicable GE technical reference for DS200SDCCG1AGD DS215SDCCG1AZZ01A. The separate Apter Power field guide covers installation checks, commissioning, diagnostics and handover.
Use the applicable General Electric documentation and site-approved installation procedure for DS200SDCCG1AGD DS215SDCCG1AZZ01A.
System position: DS200SDCCG1AGD DS215SDCCG1AZZ01A is evaluated within the documented GE AC2000, DC2000 and EX2000 drive-control systems architecture.

Compatibility boundary: Match the complete group, revision, connectors and configured signal path before replacement.
Prepare General Electric DS200SDCCG1AGD DS215SDCCG1AZZ01A using the applicable installation instructions and site isolation procedure.
Verify the complete identity

Check every token in DS200SDCCG1AGD DS215SDCCG1AZZ01A against the offered board and approved record.

Isolate all connected energy

Follow the site procedure for dc bus, field supply, control power, stored energy and electrostatic handling.

Record plugs and jumpers

Photograph and label every connector, wire jumper and hardware jumper before removal.

Preserve drive configuration

Archive the applicable GE AC2000, DC2000 and EX2000 drive-control systems settings and drawings before replacement.

Inspect mating hardware

Check connectors, ribbon cables, terminal boards and cable condition before attributing a fault to the board.

Prove the intended function

Use an approved controlled test and retain measured values, diagnostics and acceptance evidence.

Alternative Names

GE DS200SDCCG1AGD / DS215SDCCG1AZZ01A General Electric Group 1 Drive Control Card DS215SDCCG1AZZ01A

Technical notes

Pre-purchase checks: Match the offered DS200SDCCG1AGD DS215SDCCG1AZZ01A nameplate, board group, revision string, connector execution and jumper arrangement with the installed board and approved drawings.

Installed-system compatibility: Verify the exact GE AC2000, DC2000 and EX2000 drive-control systems position, mating boards, power or signal paths and configuration settings. A family reference or similar appearance does not establish interchangeability.

Quotation confirmation: Confirm available quantity, estimated dispatch date, lead-time starting event, included items and documents in writing.

FAQ View All FAQ

  • How should DS200SDCCG1AGD DS215SDCCG1AZZ01A be identified before a replacement is approved?
    Use the complete DS200SDCCG1AGD DS215SDCCG1AZZ01A marking, board group and revision string. Compare the installed position and documented drive control card assembly role before approval.
  • What evidence should be retained before removing DS200SDCCG1AGD DS215SDCCG1AZZ01A?
    Photograph the complete marking, connector positions, jumper settings and status indications. Record the position in the GE AC2000, DC2000 and EX2000 drive-control systems.
  • How should the connectors for DS200SDCCG1AGD DS215SDCCG1AZZ01A be checked during installation?
    Label each plug before removal, then restore every connection from the as-found record and the applicable GE manual. Never force a keyed connector.
  • What configuration boundary matters when commissioning DS200SDCCG1AGD DS215SDCCG1AZZ01A?
    Use the exact board group, hardware execution and approved drive record. A similar board family or physical fit does not establish interchangeability.
  • How can a suspected DS200SDCCG1AGD DS215SDCCG1AZZ01A fault be separated from wiring or carrier faults?
    Verify the documented supplies and reference signals first, inspect mating connectors and external wiring, then use a controlled substitution only after both signal paths are recorded.
  • What should be verified after fitting DS200SDCCG1AGD DS215SDCCG1AZZ01A?
    Check normal host indications and the intended drive control card assembly function under an approved controlled test. Retain measured values and diagnostics with the handover record.
  • Can DS200SDCCG1AGD DS215SDCCG1AZZ01A be replaced by a similar-looking assembly?
    No direct equivalence is established by appearance. Compare the complete code, group, revision, connector execution and installed configuration.
  • What handover record is appropriate after work on DS200SDCCG1AGD DS215SDCCG1AZZ01A?
    Retain offered and removed markings, connection photographs, jumper or configuration evidence, measured checks, functional-test results and unresolved exceptions.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.