Product image is representative; revision or series may vary. Contact us to request a specific version.
Product Describe:
Bently Nevada RS900106-05-30-05-02-00 is a reverse-mount 8 mm eddy-current proximity probe with an M10 x 1 case, 5 mm unthreaded length, 30 mm case length, 0.5 m lead and miniature ClickLoc coaxial connector.
Within a matched 3300 XL 8 mm transducer chain, Bently Nevada RS900106-05-30-05-02-00 places the short reverse-mount probe at the machine while the extension cable and Proximitor Sensor complete the measurement path.
RS900106-05-30-05-02-00
330106-05-30-05-02-00
3300 XL 8 mm
Reverse mount
Retain the exact host position, connections and configuration record. Complete controlled diagnostics and a functional test before service release.
Important Notice: Confirm RS900106-05-30-05-02-00, every companion marking and the recorded acceptance result before replacement.
The first PDF is an unchanged technical excerpt from the applicable manufacturer publication; the second provides a separate installation, verification and handover workflow.
Compact reverse-mount positions
Uses the 5 mm tip extension and 30 mm M10 case where the machine geometry requires a short probe body.
Relative shaft vibration
Measures dynamic shaft motion through the matched 3300 XL 8 mm signal chain.
Axial displacement
Tracks static shaft position when the probe gap and target geometry follow the machine design.
Speed or phase reference
Supports Keyphasor or speed service when installed against the configured shaft event.
Read the applicable product and site instructions before work. Verify RS900106-05-30-05-02-00, the installed host and every connected interface before isolation or replacement.
1
Confirm the complete RS900106-05-30-05-02-00 marking and the 330106 reverse-mount probe identity.
2
Verify the 5 mm unthreaded length, 30 mm case and M10 x 1 mounting geometry before removal.
3
Match the 0.5 m probe lead with the extension cable and Proximitor Sensor for the complete system length.
4
Protect the miniature ClickLoc connector, probe tip and 75 ohm cable from contamination and strain.
5
Record mounting depth, operating gap, cable route, shield treatment and receiving channel before work.
6
Install without twisting the cable or exceeding the approved thread engagement and bend radius.
7
Set the operating gap against the approved target with the monitoring path in maintenance mode.
8
Verify static gap, dynamic response, alarm path and configured speed or phase reference before release.
Technical notes
Match RS900106-05-30-05-02-00 to the complete installed identity, host position and companion hardware. Preserve every connection and setting; release only after diagnostics and a controlled test of compact reverse-mount shaft position and vibration sensing.