Match the complete marking
Include QUINT-PS/1AC/24DC/10 2866763 and any series, revision or assembly markings. Keep the complete reference on your enquiry and quotation.
-
Check the offered item before ordering
Request current QUINT-PS/1AC/24DC/10 2866763 label, input/output-terminal and mounting photos. Have your maintenance team compare the order number, connection arrangement and load requirements with the installed supply and applicable Phoenix Contact instructions.
Technical specifications for QUINT-PS/1AC/24DC/10 2866763
-
Manufacturer:Phoenix Contact
-
Product Category:General Automation
-
Spare Part Number:QUINT-PS/1AC/24DC/10
-
Weight:1.14 kg
-
Tariff Code:8537101190
-
Manufacturer:Phoenix Contact
-
Product series:QUINT POWER
-
Order number:2866763
-
AC input range:85 to 264 V AC
-
AC input frequency:45 to 65 Hz
-
DC input range:110 to 350 V DC; UL 508 limit 300 V DC
-
Nominal output:24 V DC, ±1%; 10 A
-
Nominal output power:240 W
-
Output adjustment:18 to 29.5 V DC; power limitation above 24 V
-
POWER BOOST:15 A permanent at 24 V, -25 to 40 °C
-
SFB current:60 A for 12 ms
-
Residual ripple:Less than 50 mV peak-to-peak
-
Operating temperature:-25 to 70 °C; derating above 60 °C
-
Derating at 60 to 70 °C:2.5% per K
-
Degree of protection:IP20
-
Mounting:Horizontal NS 35 DIN rail
Information
- Phoenix Contact QUINT-PS/1AC/24DC/10 2866763 converts the single-phase input into regulated DC power for the configured industrial loads and monitoring circuits.
Nominal output: 24 V DC / 10 A
Static reserve: 15 A POWER BOOST under specified conditions
Dynamic reserve: 60 A SFB pulse for 12 ms
The supply separates continuous capacity from its reserve functions. POWER BOOST provides 15 A continuously at 24 V within -25 to 40 °C, while SFB supplies a 60 A pulse for 12 ms to support coordinated protective-device tripping.
DC OK indicates an output above 0.9 times nominal voltage and can be integrated with the monitoring circuit within the signal-output ratings. Operation extends to 70 °C with derating above 60 °C, so output setting, cabinet temperature, starting load and branch protection must be evaluated together.
-
Phoenix Contact QUINT-PS/1AC/24DC/10 2866763 technical reference
Prepared by Apter Power. Nominal, static POWER BOOST and short-duration SFB ratings are different operating conditions. Apply the specified voltage, temperature, input and protective-device requirements to the complete installation. PDF, 5 pages, 26 KB. -
Phoenix Contact QUINT-PS/1AC/24DC/10 2866763 installation guide
Prepared by Apter Power. Product identification, configuration checks, installation preparation and functional acceptance. PDF, 5 pages, 26.8 KB.
Application scope: The following describe engineering uses of this product. Match the installed interfaces, operating conditions and intended control function before integration or replacement.
-
Industrial control cabinets
Provide regulated 24 V DC power for compatible control loads. Size the supply for steady demand, startup behavior and the enclosure temperature. -
Heavy-load startup
Use the POWER BOOST reserve for applicable load-starting requirements. Preserve the 24 V output and temperature conditions of the 15 A rating. -
Selective branch protection
Coordinate SFB pulse capability with suitable branch circuit breakers and wiring. Verify the complete fault-current path and protective-device response. -
Monitored DC distribution
Connect the DC OK and load-status signals to the intended monitoring system. Match relay or active-output loading and configured alarm response.
Match QUINT-PS/1AC/24DC/10 and 2866763 together; do not infer equivalence from another QUINT supply with the same output current.
Apply the approved isolation and absence-of-voltage procedure. The unit has hazardous input voltage even though its output is low-voltage DC.
Adjust within 18 to 29.5 V DC for the connected loads. Account for constant-capacity restrictions above 24 V.
Do not describe the 60 A, 12 ms SFB pulse as continuous output. The 15 A static reserve also has specific voltage and temperature conditions.
Preserve the manufacturer mounting clearances and derate the load above 60 °C. Confirm cabinet temperature at the actual installation position.
Coordinate input protection, branch breakers and DC OK/load signals with the installation. Confirm polarity and load behavior before operational release.
Alternative Names
Technical notes
System relationship: Match AC or DC input conditions, protective grounding and upstream protection. Keep input isolation separate from output DC OK indication.
Configuration boundary: Nominal, static POWER BOOST and short-duration SFB ratings are different operating conditions. Apply the specified voltage, temperature, input and protective-device requirements to the complete installation.
Technical reference: Phoenix Contact QUINT-PS/1AC/24DC/10, order 2866763, product technical data (29 October 2026).
FAQ View All FAQ
-
What nominal output does QUINT-PS/1AC/24DC/10 2866763 provide?The nominal output is 24 V DC, ±1%, at 10 A, corresponding to 240 W. Output adjustment is available from 18 to 29.5 V DC with power restrictions above 24 V.
-
What AC supply range applies to QUINT-PS/1AC/24DC/10 2866763?The input accepts 85 to 264 V AC at 45 to 65 Hz. Select the input protection and wiring for the actual installation.
-
Can QUINT-PS/1AC/24DC/10 2866763 operate from a DC input?The specified DC input range is 110 to 350 V DC, with a 300 V DC limit for the UL 508 condition. Follow the applicable DC input and protection requirements.
-
What does POWER BOOST mean for QUINT-PS/1AC/24DC/10 2866763?It provides a 15 A static reserve at 24 V DC, continuously within -25 to 40 °C. Preserve the stated input and environmental conditions.
-
What is the SFB output capability of QUINT-PS/1AC/24DC/10 2866763?Selective Fuse Breaking provides 60 A for 12 ms to support coordinated protective-device tripping. It is a short pulse, not a continuous load rating.
-
What ripple limit applies to QUINT-PS/1AC/24DC/10 2866763?Residual ripple is below 50 mV peak-to-peak at nominal values. Verify the load and measurement conditions when evaluating a supply.
-
What temperature derating is required for QUINT-PS/1AC/24DC/10 2866763?The operating range is -25 to 70 °C. Between 60 and 70 °C, reduce the permissible load by 2.5% per kelvin.
-
How does the DC OK signal on QUINT-PS/1AC/24DC/10 2866763 operate?DC OK indicates an output above 0.9 times the nominal voltage. The active signal supports up to 20 mA, and the floating relay contact must remain within its specified switching limits.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.