Match the complete marking
Include 330701-00-40-10-11-05 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered 330701-00-40-10-11-05 reference with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 330701-00-40-10-11-05
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330701-00-40-10-11-05
-
Weight:0.1 kg
-
Tariff Code:8537101190
-
Probe family:3300 XL 11 mm
-
Mounting thread:1/2-20 UNF
-
Cable armor:No armor
-
Unthreaded length:0.0 in
-
Overall case length:4.0 in
-
Total probe length:1.0 m
-
Connector:ClickLoc with connector protector, FluidLoc cable
-
Approval selection:Multiple approvals
-
Nominal probe resistance:5.9 +/-0.5 ohm
-
Matched-system linear range:4.0 mm (160 mil)
-
Matched-system scale factor:3.94 V/mm (100 mV/mil)
-
Recommended gap:2.5 mm (100 mil)
-
Matched-system frequency response:0 to 8 kHz, +0/-3 dB typical
-
Probe cable impedance:75 ohm triaxial
-
Reference target:AISI 4140 steel, 31 mm diameter or larger
-
Minimum bend radius:25.4 mm
-
Probe temperature:-52 to +177 deg C operating and storage
Information
- This inch-thread 11 mm configuration combines a long 4.0 in case with a protected FluidLoc joint, so usable thread engagement and connector-envelope clearance must be reviewed together.
Protected FluidLoc termination: 1.0 m unarmored FluidLoc lead with ClickLoc connector protector.
11 mm measurement chain: 4.0 mm range and 3.94 V/mm scale apply to the complete matched system at the stated conditions.
The 1.0 m FluidLoc lead is unarmored and terminates through a connector protector. FluidLoc construction does not remove the need for bend control and strain relief, and the protector must remain accessible for inspection without loading the coaxial contacts.
A matched 11 mm chain provides 4.0 mm linear range from approximately 0.5 to 4.5 mm and uses a 2.5 mm recommended gap under the stated reference conditions. Close probe spacing or a small shaft can introduce cross-talk, so geometry and channel response must be proven together.
-
Bently Nevada 330701-00-40-10-11-05 official technical excerpt
Selected manufacturer pages covering the applicable family, technical data and exact order-code fields. -
Bently Nevada 330701-00-40-10-11-05 engineering guide
Apter Power installation, configuration, diagnostic and acceptance guidance.
Platform applications: The uses below require the documented 3300 XL 11 mm proximity transducer system companion components and approved machine drawing.
-
Long-reach radial vibration
Use at an inch-thread bearing location where the 4.0 in case reaches the shaft and surrounding probe spacing satisfies the 11 mm geometry. -
Thrust-position channel
Apply to an approved axial target with enough travel around the recommended 2.5 mm gap and controlled cross-talk. -
Fluid-prone local route
Use the FluidLoc lead where specified, while retaining a dry, accessible protected ClickLoc junction. -
Inch-thread installed-base renewal
Match the 1/2-20 thread, long case, protector and multiple-approval code when replacing the channel.
More than 0.750 in of 1/2-20 engagement can bind the probe body; verify the mounting boss before installation.
Check bracket stiffness and clearance so the 4.0 in body is not used as a structural member.
Prevent abrasion and tension even though the cable jacket is selected for fluid resistance.
Confirm full protector engagement without twisting the ClickLoc contacts or trapping contamination.
Confirm target and shaft diameter plus separation from adjacent probes before final gap setting.
Prove the required displacement span against Proximitor output and monitor indication before return to service.
Alternative Names
Technical notes
Thread engagement: Keep 1/2-20 engagement at or below the documented 0.750 in limit and verify support for the remaining 4.0 in case.
Protected FluidLoc joint: Inspect protector seating, maintain the 25.4 mm bend radius and clamp the unarmored 1.0 m lead independently.
Cross-talk review: Confirm target diameter, shaft diameter and spacing to adjacent probes before using the full 4.0 mm measurement region.
FAQ View All FAQ
-
Why is the 0.750 in engagement limit important for 330701-00-40-10-11-05?Its 1/2-20 case can bind when the mounting thread is too deep; measure usable engagement and support the remaining 4.0 in body.
-
How does the option 11 termination affect installation of 330701-00-40-10-11-05?It combines a FluidLoc lead with a connector protector, requiring both a protected joint envelope and independent support for the unarmored cable.
-
What cross-talk checks are needed around 330701-00-40-10-11-05?Review flat-target size, shaft diameter and tip separation from neighboring probes, then compare static outputs before functional testing.
-
Which system length can be used with 330701-00-40-10-11-05?Use the 1.0 m probe only with the extension cable and 11 mm Proximitor that complete the installed five- or nine-meter chain.
-
How should the recommended gap for 330701-00-40-10-11-05 be verified?Set the approved stopped-machine datum near 2.5 mm or its accepted bias equivalent and verify usable travel on both sides.
-
Does FluidLoc cable make the connector of 330701-00-40-10-11-05 submersible?No; keep the ClickLoc joint and protector clean, dry and correctly seated while applying the cable construction only within its documented route.
-
What indicates a mounting problem after fitting 330701-00-40-10-11-05?A shifted bias, unstable reading or poor repeatability can result from excessive engagement, case loading, target geometry or cross-talk.
-
What must the handover record include for 330701-00-40-10-11-05?Record engagement depth, case support, protected-joint condition, companion identities, gap or bias and verified long-range channel response.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studies-
GE IS420UCSBH4A: Confirm the Offered Controller and Release TermsRead case > -
Invensys 3806E Sourcing: Five Spares Delivered to the CustomerRead case > -
ATV930C16N4 Heavy Drive Packing and Insured ShippingRead case > -
24 Siemens Spare Parts Delivered to an Australian Waste Management FacilityRead case >
You May Also Like
Product Browsing History
-
330701-00-40-10-11-05Product Details -
22B-B024N104Product Details -
330102-00-28-05-02-05Product Details -
330102-00-60-05-02-05Product Details -
07NG63R1 GJV3074313R1Product Details -
07KP64 GJR5240600R0101Product Details -
07EA61R1 GJV3074351R1Product Details -
330130-040-03-CNProduct Details -
190501-07-00-04Product Details -
330500-07-02Product Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.