Match the complete marking
Match the complete Bently Nevada 330104-08-15-10-02-00 marking, hardware execution and connection arrangement to the installed position before approving the order.
-
Check the offered item before ordering
Request clear photographs of the offered 330104-08-15-10-02-00 and ask your maintenance team to compare its markings and interfaces with the installed equipment and applicable Bently Nevada instructions.
Technical specifications for 330104-08-15-10-02-00
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330104-08-15-10-02-00
-
Weight:0.14 kg
-
Tariff Code:8537101190
-
Sensing principle:Non-contact eddy current
-
Tip diameter:8 mm
-
Mounting thread:M10 x 1
-
Unthreaded section:80 mm
-
Case length:150 mm
-
Integral lead length:1.0 m
-
Lead construction:Armored standard coaxial cable
-
Connector:Miniature coaxial ClickLoc
-
Nominal system sensitivity:7.87 V/mm (200 mV/mil)
-
System linear range:2 mm (80 mils)
-
Standard calibration target:AISI 4140 steel
Information
- Bently Nevada 330104-08-15-10-02-00 requires the bracket engagement and working gap to be checked together so the sensor remains stable through the expected target movement.
Cable construction: Armored standard coaxial lead
Signal path: Matched probe, cable arrangement and Proximitor
The 1.0 m integral lead is combined with a compatible extension cable to establish the selected system electrical length. The probe cable length is not the total system length, and a mechanically matching extension does not establish electrical compatibility.
The conditioner output represents both static gap and dynamic target motion. Target material, mounting geometry and receiver configuration must remain within the intended measurement design. Armor protects the routed lead but does not replace proper support or connector protection.
330104-08-15-10-02-00 Original Technical Excerpt
The original technical excerpt supports 330104-08-15-10-02-00 configuration review. The separate Apter Power field guide organizes practical diagnostic checks. PDF · 5 pages.330104-08-15-10-02-00 Installation & Verification Guide
Apter Power engineering guide for the installed signal, power or communication path and controlled acceptance. PDF · 5 pages.
Application scope: The following uses describe supported engineering roles; they do not establish interchangeability with another model or remove application-specific validation.
Fluid-film bearing monitoring
Measure shaft motion with a compatible proximity channel.Static position measurement
Observe conductive target position within the matched-system range.Reference-pulse sensing
Support a properly configured Keyphasor or speed-reference arrangement.Probe replacement service
Match mounting geometry and electrical length to the installed chain.
Record the probe position, target material, sensing direction and monitor channel before removal. Compare the 150 mm case and 80 mm unthreaded portion with the actual bracket and working space. Preserve the original operating gap and the accepted channel scaling so a mechanical replacement does not silently alter the measurement baseline.
Trace the 1.0 m integral lead to its conditioner and identify the complete calibrated arrangement. This probe is used with the selected Proximitor electrical length through the compatible extension cable. Keep the machine protection in its approved maintenance state while the channel is interrupted, and label the coaxial connections before disconnecting them.
Inspect the probe tip, armored lead and connector for damage or contamination before installation. Route the armor with support that does not pull on the probe or coaxial connection. Secure the intended mounting position and protect the connector using the applicable installation method, then verify the gap again after locking the mechanical arrangement.
Use the matched chain and a suitable target to observe output at controlled gap positions within the intended operating region. Compare direction and sensitivity with the system requirements, allowing for target material and the receiving instrument. Keep any dynamic interpretation separate from a static electrical verification.
Restore the channel to the intended monitor and confirm scaling, normal gap indication and the configured protection response. Perform alarm or reference-pulse checks only under the approved controlled test method. Remove temporary stimuli and reconcile bypasses before returning the measurement to service, retaining the final probe and conditioner identities.
Probe configuration follows the metric ordering table; stated system performance requires a matched transducer chain and the specified target conditions.
Alternative Names
Technical notes
Configuration baseline: Keep the installed 3300 XL 8 mm system arrangement aligned with the complete 330104-08-15-10-02-00 reference and its assigned system role.
Acceptance boundary: Compare the electrical or communication response with the intended application outcome before releasing maintenance controls.
Technical reference: Bently Nevada 3300 XL 8 mm Proximity Transducer System, 141194 Rev. AN. Probe configuration follows the metric ordering table; stated system performance requires a matched transducer chain and the specified target conditions.
FAQ View All FAQ
-
How can insufficient thread engagement affect an installation using 330104-08-15-10-02-00?A mount can accept the nominal thread while failing to retain the probe securely at the required position. Compare the unthreaded section and usable case geometry with the bracket. Recheck the signal after mechanical locking.
-
Why should 330104-08-15-10-02-00 gap be checked across the expected shaft position range?The operating position must remain within the useful linear range during normal movement. A centered reading at rest can become unsuitable after axial or radial displacement. Validate the application envelope rather than one static point.
-
What should be checked if 330104-08-15-10-02-00 appears noisier after a cabinet modification?Compare shield and ground arrangements, cable routing and the proximity of switching circuits with the previous installation. Inspect connector integrity, then evaluate the signal with the target fixed before blaming machine vibration.
-
Can a longer armored assembly replace 330104-08-15-10-02-00 without changing anything else?Only after comparing mechanical geometry and calibrated electrical length with the complete system. Armor alone does not establish interchangeability. The conditioner and extension arrangement must remain compatible with the replacement.
-
Why can moisture at the 330104-08-15-10-02-00 connector cause intermittent measurements?The coaxial interface relies on an intact electrical connection and insulation. Contamination can alter that path even when the connector appears mechanically engaged. Inspect, dry or replace components using the approved maintenance procedure and retest.
-
How should 330104-08-15-10-02-00 response be compared with a second vibration channel?Check target location, sensor orientation, conditioning and monitor scaling before interpreting differences. Two channels at different positions need not produce identical signals, even when both are correctly calibrated.
-
What is the purpose of checking 330104-08-15-10-02-00 at more than one gap value?Multiple controlled points reveal scale and linearity behavior that a single reading cannot establish. Test across the intended working region using the matched chain and appropriate target, then compare with the system acceptance criteria.
-
Why must alarm testing follow electrical verification of 330104-08-15-10-02-00?A correct sensor response does not establish the receiving monitor logic or relay path. Once the measurement is proven, verify the configured alarm response under a controlled test and restore the normal protection state.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.