-
Match the complete marking
Match the full 2098-DSD-010X-DN label, series, electrical rating and motor/feedback pairing with the installed axis before ordering.
-
Check the offered item before ordering
Request photos of the offered 2098-DSD-010X-DN and have your maintenance team compare them with the installed drive and applicable Rockwell Automation Ultra3000 documentation before ordering.
Technical specifications for 2098-DSD-010X-DN
-
Manufacturer:Allen-Bradley
-
Product Category:Servo Drives
-
Weight:1.96 kg
-
Tariff Code:8537101190
-
Catalog variant:Ultra3000 1 kW with indexing and DeviceNet
-
AC input:100–240 V rms nominal, single phase; 47–63 Hz
-
Nominal AC input current:9 A rms for the 2098-DSD-010 rating class
-
Continuous power output:1.0 kW at 230 V AC; 0.5 kW at 115 V AC
-
Continuous output current:5 A, zero-to-peak basis
-
Intermittent output current:15 A, zero-to-peak basis
-
DC bus overvoltage:400 V DC in the 230 V class power table
-
Bus capacitance:1880 µF in the 2098-DSD-010 rating class
-
Motor feedback connection:CN2, 15-pin
-
User I/O connection:CN1, 44-pin
-
Serial setup connection:CN3, 9-pin; use Ultraware setup procedure
-
Power wiring:TB1; earth grounding and cable shielding required
-
Indexing setup:Configure motor, tune, then test non-indexing and indexing moves
-
DeviceNet interface:Present; connector, node-address and data-rate switches, module and network LEDs
-
Network rate:125, 250 or 500 kbps; validate topology and drop budget
Information
- The 2098-DSD-010X-DN converts single-phase AC to controlled servo motion and uses a motor feedback path, user I/O and Ultraware setup. Its DeviceNet card adds network configuration and status.
Control path: Stored motor and indexing parameters with user I/O
Service path: CN3 serial setup plus DeviceNet network configuration
Rockwell commissioning instructions identify 2098-DSD-010X-DN in the 500 W–2 kW front-panel group. CN1 is the 44-pin user I/O connection, CN2 is the 15-pin motor feedback connection and CN3 is the 9-pin serial connection. Ultraware is used to select the motor, tune the drive and perform controlled non-indexing and indexing move tests.
The -DN variant adds a DeviceNet connector, node-address and data-rate switches, and separate module/network status indicators. Plan the cable system and voltage drop before adding the drive, then read back the address, rate, network state and indexing configuration.
-
2098-DSD-010X-DN Technical Reference
Rockwell Automation excerpts · PDF, 7 pages. Ultra3000 electrical ratings, 2098-DSD-010X-DN interface and commissioning sequence. -
2098-DSD-010X-DN Installation & Commissioning Guide
Apter Power field guide · PDF, 4 pages. 2098-DSD-010X-DN connection map, index tests, service decisions and handover.
Platform applications: An indexing machine axis may communicate over DeviceNet when its physical node, rate, cable system and control mapping are engineered for the installed network.
-
Indexed positioning axis
Compare move distance, direction, speed and travel limits with the approved machine program before enabling the load. -
Motor and feedback retrofit
Confirm motor catalog, feedback connector and cable shielding; read back the tuned motor record and prove rotation at low risk. -
Machine I/O integration
Check CN1 input/output assignment and the machine interlock chain before repeating an indexed move. -
DeviceNet coordinated axis
Verify node address, data rate, module/network LEDs and controller mapping; record network state before and after the test.
Remove AC power, wait for the DC bus to discharge and verify a safe state before handling TB1, motor terminals or cables.
Confirm 2098-DSD-010X-DN on the offered and installed labels; the DeviceNet and non-DeviceNet versions have different interface requirements.
Apply the source Series A/B or C power-cycle limits and appropriate inrush protection; identify the actual series before testing.
Bond protective earth, motor case and cable shield as specified; inspect the feedback path before enabling torque.
Save the original parameter file, verify motor selection and I/O assignment, then run a restrained non-indexing test before indexing.
Check cable topology, network power, address, rate and module/network LEDs before accepting a coordinated move.
Alternative Names
Technical notes
Rating basis: The 2098-DSD-010 power-table values are for the 230 V class and use zero-to-peak output-current notation.
Variant boundary: The full -DN suffix identifies the DeviceNet indexing variant; its network wiring and commissioning differ from the non-DN unit.
Technical reference: Rockwell Automation 2098-IN003E-EN-P / 2098-DU003B and 2098-IN005C-EN-P.
FAQ View All FAQ
-
How do I confirm that a 2098-DSD-010X-DN suits the installed axis?Read the entire 2098-DSD-010X-DN label and series, then compare the motor, feedback, CN1 wiring, supply and saved parameters. Also compare DeviceNet address, rate and controller mapping.
-
What should I do if 2098-DSD-010X-DN powers up but will not move?Read the seven-segment status and the saved Ultraware configuration, then check enable/interlocks, motor selection and CN1 signals. Keep the load restrained for a non-indexing test before trying an indexed move.
-
Why does 2098-DSD-010X-DN require a series check before repeated power cycling?The 2098-DU003B update gives different inrush limits for Series A/B and Series C. Read the actual series label, apply the corresponding contactor-cycle limit and investigate an abnormal start before cycling again.
-
How should the motor feedback on 2098-DSD-010X-DN be accepted?Match the motor catalog and CN2 connector/cable with the axis drawing, inspect shield termination, then compare commanded and observed direction during a restrained test. Stop if feedback or motion is unstable.
-
Which output-current figure applies to 2098-DSD-010X-DN?The 2098-DSD-010 class table lists 5 A continuous and 15 A intermittent, both zero-to-peak. Match the motor and duty cycle to the source selection rules; do not treat the intermittent value as continuous.
-
How is a replacement for 2098-DSD-010X-DN selected?The exact DeviceNet catalog entry lists an engineering replacement category without a specified drop-in part. Compare motor, feedback, I/O, DeviceNet communication, program and safety architecture before selecting a new platform.
-
What should I check when 2098-DSD-010X-DN has DeviceNet communication faults?Record the module and network LED states, node address and selected data rate; compare cable topology, network supply, voltage drop and controller mapping with the approved network plan.
-
What should be recorded after commissioning 2098-DSD-010X-DN?Retain the full drive/motor labels, series, supply measurement, motor/feedback and CN1 wiring, saved parameter file, status/fault record, controlled motion results, and DeviceNet address/rate and LED states.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.








