Match the complete marking
Include ZINT-571 3AUA0000077333 in full and compare it with the removed board, drive type label and service records. Retain any additional rating or assembly marking shown on the installed unit.
-
Check the offered item before ordering
Request current label and connector photos. Have the maintenance team compare the offered ZINT-571 3AUA0000077333 bare board with the installed drive and ABB rated-spare guidance before approving a replacement.
Technical specifications for ZINT-571 3AUA0000077333
-
Manufacturer:ABB
-
Product Category:Servo Drives
-
Spare Part Number:3AUA0000077333
-
Weight:0.25 kg
-
Tariff Code:8537101190
-
Product identity:ZINT-571 3AUA0000077333
-
Board class:Main circuit interface board
-
Supply scope:Single bare board
-
Associated drive family:ACS880-01, subject to installed configuration
-
Associated control unit:ZCU in the documented board family
-
Control-side link:37-pin D-sub in ABB ZINT-571 / -592 family description
-
Interface function:Internal power supply; family description
-
Power-stage function:Gate drivers; family description
-
Brake-control function:Braking chopper driver; family description
-
Measurement function:ADC measurements; family description
-
Input-stage function:Input bridge control interface; family description
-
Auxiliary function:Main fan interface; family description
-
Drive-family class:380-500 V three-phase ACS880-01 grouping; not a bare-board rating
-
Spare selection:ABB directs rated spare selection to ZINT/BINT board procedure
-
Installation identity:Verify drive frame, ZCU and rating ID before interchange
Information
- ABB ZINT-571 3AUA0000077333 is the offered bare main circuit interface board for an applicable ACS880 drive arrangement.
Control-side relationship: ZCU through a 37-pin D-sub family interface
Supply scope: Single bare board; rated spare kit not included
In ABB's ACS880 board-family presentation, the ZINT-571 / -592 interface family sits between the ZCU control unit and main-circuit functions. The group description includes gate driving, ADC measurement, braking-chopper control and the input-bridge interface. These are functional relationships, not standalone board terminal ratings.
The ACS880-01 family diagram groups ZINT-571 with a 380-500 V three-phase drive class. Confirm the actual frame, control unit, board label and rating identity using the installed drive record. A drive-class label cannot establish direct interchangeability of an unrated bare board.
-
ZINT-571 technical reference
Board-family functional boundaries and exact catalog identity; one-page technical map. -
ZINT-571 3AUA0000077333 engineering technical data
Board identity, control-interface context, connector and replacement boundaries supported by ABB material. Apter Power PDF, 1 page.
Application boundary: Verify the exact drive frame, ZCU and service-board rating before transfer to an operating installation.
-
Main-circuit interface
The ZINT board-family presentation places internal supply, gate driving and measurement at the control-to-power boundary. Follow the actual drive drawing for connection mapping. -
Control unit pairing
The family description shows a 37-pin D-sub relationship to ZCU. Match the installed cable, control unit version and connector condition. -
Frame and voltage class
The ABB board map groups ZINT-571 in a 380-500 V three-phase drive family. This does not specify the board input supply or authorize every frame. -
Rated spare boundary
ABB treats the board code separately from a rated service kit. Confirm whether the installed application needs rating ID preparation.
Follow the ACS880 hardware manual: lock out supplies, allow DC-link discharge and measure for absence of voltage before work.
Photograph the installed board, control cable and power-stage connections before removal. Do not infer pinout from family illustrations.
Compare drive type, frame, existing board code and rating ID with ABB service-board selection guidance.
After reassembly, check parameters, fan operation, diagnostics and approved functional tests before release.
Alternative Names
Technical notes
Integration relationship: ZINT-571 belongs to the ABB ACS880-01 main-circuit interface board family. Confirm the installed drive frame, ZCU arrangement and rating identity before accepting this bare board as a replacement.
Electrical safety: Follow the applicable ACS880 hardware manual for isolation, DC-link discharge and measured absence of voltage before handling the board.
Technical reference: ABB ACS880 board-family presentation and ABB catalog identity for ZINT-571 3AUA0000077333. Family functions do not establish a standalone electrical rating for the offered board.
FAQ View All FAQ
-
How should an engineer determine whether ZINT-571 3AUA0000077333 can replace the installed interface board?Compare the full removed-board identifier, drive type and frame, ZCU arrangement and rating ID. ABB distinguishes the bare board code from the rated spare-board procedure, so a matching family name alone does not prove interchangeability.
-
What evidence is needed to approve ZINT-571 3AUA0000077333 for a specific ACS880 drive rating?Read the drive type and rating label and compare the installed board configuration with ABB rated-spare guidance. The ACS880 family voltage grouping is not an individual bare-board electrical rating.
-
How can the control connection of ZINT-571 3AUA0000077333 be checked before a board swap?The ABB board-family presentation identifies a 37-pin D-sub link to ZCU. Photograph the actual connector and cable routing, then compare them with the drive-specific drawing before disconnection.
-
What must be isolated before technicians handle ZINT-571 3AUA0000077333?Use the ACS880 hardware manual for the installed drive: isolate and lock all supplies, allow the DC-link discharge interval, and measure the input and DC terminals against PE. A qualified electrician should confirm the safe state.
-
If a drive reports a gate-drive or measurement fault, does ZINT-571 3AUA0000077333 automatically need replacement?No. The ABB family presentation places those interfaces on ZINT, but the fault may originate in wiring, gate adapters, sensors or the power stage. Capture the diagnostic history and isolate the failed circuit with the drive service procedure.
-
How should the fan interface be assessed when fitting ZINT-571 3AUA0000077333?ABB assigns a main-fan interface to the ZINT family. Confirm the actual frame fan assembly, connector and cable path against the installed drive drawing, then test the fan under the approved commissioning procedure.
-
What configuration records should be retained before changing ZINT-571 3AUA0000077333?Record the drive type and serial label, ZCU version, rating ID, parameter backup, board labels, connector positions and fault log. These records support both spare selection and post-exchange comparison.
-
How should a replacement ZINT-571 3AUA0000077333 be accepted after installation?After the site-approved power-up, compare rating identity, parameters, diagnostic state and fan operation with the as-found record. Perform the drive-specific functional test before returning the machine to service.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
ZINT-571 3AUA0000077333Product Details -
UAD141A02 3BHE012095R0002Product Details -
TC520 3BSE001449R1Product Details -
AI830A 3BSE040662R1Product Details -
RINT-5611C 68718929Product Details -
3BHE004573R0142 UFC760BE142Product Details -
1SFB536068D1011Product Details -
YPQ110A 3ASD573001A5Product Details -
CPM810Product Details -
XN05Product Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.