Match the complete marking
Include AI830A 3BSE040662R1 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available identification and connector photos. Have your maintenance team compare the offered AI830A 3BSE040662R1 and its S800 termination unit with the installed station and applicable ABB documentation.
Technical specifications for AI830A 3BSE040662R1
-
Manufacturer:ABB
-
Product Category:DCS Systems
-
Spare Part Number:ABB AI830A 3BSE040662R1
-
Weight:0.24 kg
-
Tariff Code:8537101190
-
Update cycle time:150 + 95 × active channels ms
-
CMRR at 50/60 Hz:>120 dB (10 Ω load)
-
Input channels:8
-
NMRR at 50/60 Hz:>60 dB
-
Sensor wiring:3-wire
-
Rated insulation voltage:50 V
-
Conversion resolution:14 bit
-
Interference rejection:Selectable 50 or 60 Hz
-
Dielectric test voltage:500 V AC
-
Operating temperature:0 to +55 °C (approvals: +5 to +55 °C)
-
Modulebus 24 V draw:50 mA
-
Dissipated power:1.6 W
-
Modulebus 5 V draw:70 mA
Information
- AI830A 3BSE040662R1 collects temperature and resistance signals in an S800 I/O installation and sends configured channel values to the host controller.
Field interface: Three-wire sensor connection
Diagnostic role: Wire and ground-fault detection
Channels can be configured individually, allowing different supported measurement ranges within one module. Selectable 50 or 60 Hz rejection helps match local mains interference, while open-circuit, short-circuit and ground-fault diagnostics support fault isolation.
The module is mounted on a compatible S800 module termination unit. Verify the selected MTU, sensor cable termination, channel configuration and controller database together; a different S800 analog module is not a substitute solely because the connector fits.
-
ABB AI830A 3BSE040662R1 technical reference
Apter Power technical reference - PDF, 2 pages. S800 RTD identity, eight-channel measurement data, diagnostics and application boundaries. -
ABB AI830A 3BSE040662R1 installation guide
Apter Power installation verification guide - PDF, 1 page. Sensor wiring, MTU matching, configuration review and channel acceptance checks.
Sensor compatibility: Use supported three-wire RTDs or configured resistance signals; check each channel range.
-
Process temperature monitoring
Connect supported RTDs at measurement points whose approved I/O design specifies AI830A channels. -
Resistance sensing
Use individually configured resistance inputs where the controller database requires measured ohmic values. -
S800 distributed I/O cabinets
Install with an ABB-listed compatible module termination unit and matching field wiring. -
Maintenance replacement
Restore the same channel sensor selections, filter setting and fault handling in the host configuration.
Record sensor type, channel assignment and three-wire terminal positions before removal.
Confirm the installed termination unit is approved for AI830A and that all field terminals correspond.
Keep the configured 50 or 60 Hz filter setting consistent with the site measurement design.
Inspect lead continuity and cable shielding before attributing a channel fault to the module.
Capture each channel range, scaling and diagnostic treatment from the controller database.
Apply a known resistance or temperature simulator and record each channel response after replacement.
Alternative Names
Technical notes
Sensor selection: Each channel requires its own supported RTD or resistance configuration.
Fault interpretation: Open, short and ground alarms should be checked against the field circuit.
Termination: MTU compatibility and terminal allocation are part of the approved system design.
FAQ View All FAQ
-
How should Pt100 and Ni120 channels on AI830A 3BSE040662R1 be differentiated?Check each channel type and range in the S800 configuration and compare with the connected sensor label.
-
What does a ground-fault indication on AI830A 3BSE040662R1 require?Inspect the sensor wiring, cable insulation and grounding arrangement before replacing the module.
-
Can a two-wire RTD be connected to AI830A 3BSE040662R1 without redesign?Use only a wiring and configuration method approved for the installation; the published module description is three-wire.
-
What affects mains-noise rejection on AI830A 3BSE040662R1?The configured 50/60 Hz notch and the sensor cable routing affect measured interference.
-
How can an open-circuit alarm on AI830A 3BSE040662R1 be isolated?Check the field RTD, lead continuity, terminals and configured sensor type using the approved diagnostic procedure.
-
What should be retained before changing the MTU under AI830A 3BSE040662R1?Keep the terminal diagram, sensor assignment and approved MTU article number.
-
How should each AI830A 3BSE040662R1 channel be accepted?Use a calibrated simulator at known points and verify engineering units, alarms and controller values.
-
Can an AI830 replace AI830A 3BSE040662R1 without checking its article and configuration?No; compare exact module and MTU compatibility and restore the documented channel setup.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.