Match the complete marking
Include SA610 3BHT300019R1 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered SA610 3BHT300019R1 reference with the installed equipment and applicable ABB documentation.
Technical specifications for SA610 3BHT300019R1
-
Manufacturer:ABB
-
Product Category:DCS Systems
-
Spare Part Number:SA610 3BHT300019R1
-
Weight:1.66 kg
-
Tariff Code:850440
-
AC input selections:110 / 120 / 220 / 240 V AC
-
DC input selections:110 / 220 / 250 V DC
-
Rated DC output:24 V DC
-
Rated output power:60 W
Information
- The input selection must be matched to the installed source and unit connection drawing. The set of AC and DC values is not an unrestricted continuous input range and does not authorize an arbitrary terminal connection.
Selectable source context: AC and DC supply choices require different source verification.
Bounded output duty: Connected control loads must remain within the documented output power budget.
The technical information identifies discrete AC and DC input selections. Verify the actual available source and the receiving unit connection diagram before wiring. Do not describe the lowest and highest listed inputs as a universal range or infer automatic selection, tolerance or frequency limits from the list.
The 24 V DC output has a specified power limit. Review the total connected demand and the approved starting behavior of the control installation, then measure the output at the receiving load. A no-load voltage check alone does not demonstrate that the restored controller supply is accepted.
SA610 3BHT300019R1 Technical Reference
Apter Power technical reference covering the documented product data and their application boundaries. PDF · 1 pages · 88.6 KB.SA610 3BHT300019R1 Installation & Commissioning Guide
Input Selection and Controller-Load Acceptance. Resolve the actual source and controller connection first, then verify the supply under the load that the installation requires. PDF · 2 pages · 92.2 KB.
Application scope: Choose the AC or DC input arrangement from the actual source and unit drawing. No undocumented automatic-range or redundancy function is assumed.
AC110 control power
Compare the existing SA610 position and controller power connection. Retain the installed source selection before reconnecting the control load.AC160 supply restoration
Verify the receiving supply interface and connected demand against the SA610 rating. Check output at the controller after the approved startup sequence.MasterPiece 90 maintenance
Match the retained controller power arrangement and full 3BHT identity. Do not select another legacy supply solely by output voltage.AC or DC source choice
Identify the actual source type and selected nominal value. Follow the installed connection drawing rather than treating the complete input list as one continuous range.
Distinguish AC and DC before wiring any input terminal.
Match the listed source selection to the actual installed diagram.
Compare the connected demand with the 60 W output rating.
Record connector and return assignments before removing the original module.
Check retention, insulation and signs of connection heating.
Observe controller startup and output behavior under the approved operating condition.
Alternative Names
Technical notes
Discrete selections: The listed input values do not establish a continuous input range or automatic selection.
Output budget: The power limit applies to the connected supply duty, not merely the measured no-load voltage.
Power-to-current calculation: 60 W divided by 24 V gives a 2.5 A nominal DC equivalent for demand review. This calculation is not an independently published current rating, startup allowance or overload curve.
FAQ View All FAQ
-
Does SA610 3BHT300019R1 automatically accept every voltage between the lowest and highest listed inputs?That behavior is not established. The product information gives discrete AC and DC selections. Verify the actual unit connection diagram and source selection before wiring.
-
Can any 24 V supply replace SA610 3BHT300019R1 in an AC160 installation?No direct interchange is established by the output voltage alone. Compare the receiving controller interface, input arrangement, output budget and installation requirements.
-
How should an AC source be distinguished from a DC source when selecting SA610 3BHT300019R1?Identify source type and nominal value from the installation record and confirm them by the approved measurement method. Do not apply an AC terminal assumption to a listed DC selection.
-
Why is a no-load voltage check insufficient for accepting SA610 3BHT300019R1?The installed load must be supported within the rated power duty. Verify output at the receiving controller and observe the approved startup and operating behavior.
-
Can the input-selection list of SA610 3BHT300019R1 be used to infer a frequency or voltage tolerance?No. Those limits are not established by the nominal selections. Use the actual unit drawing and applicable equipment specifications for the installation.
-
What should be reviewed before adding another load to SA610 3BHT300019R1?Recalculate the connected power demand and review the approved starting behavior and wiring/protection arrangement. The presence of a 24 V output does not establish unused capacity.
-
How can the 60 W rating help review connected demand on SA610 3BHT300019R1?At the nominal 24 V output, 60 W / 24 V = 2.5 A is a calculated steady-state DC equivalent. Compare the connected power demand with 60 W, then assess startup separately; this calculation establishes neither a transient allowance nor an overload curve.
-
What distinguishes source-selection trouble from a voltage drop after fitting SA610 3BHT300019R1?Verify the actual AC/DC source and the unit’s selected input arrangement first. Then compare the supply output with voltage at the receiving controller during the approved startup; the difference helps locate a distribution/return problem rather than attributing every failed start to the converter.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
SA610 3BHT300019R1Product Details -
330703-020-110-10-01-05Product Details -
330101-00-10-10-02-05Product Details -
330101-00-30-05-02-00Product Details -
330103-00-03-05-01-05Product Details -
330102-00-60-05-02-05Product Details -
07NG63R1 GJV3074313R1Product Details -
07KP64 GJR5240600R0101Product Details -
07EA61R1 GJV3074351R1Product Details -
330130-040-03-CNProduct Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.