Match the complete marking
Include CI858K01 3BSE018135R1 and the CI858 and TP858 markings visible on the kit. Keep the complete reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available module, baseplate and optical-connector photos for CI858K01 3BSE018135R1. Have your maintenance team compare the offered kit with the installed AC 800M configuration and applicable ABB documentation.
Technical specifications for CI858K01 3BSE018135R1
-
Manufacturer:ABB
-
Product Category:DCS Systems
-
Spare Part Number:CI858K01 3BSE018135R1
-
Weight:0.46 kg
-
Tariff Code:8537101190
-
Order identity:CI858K01; article 3BSE018135R1
-
Kit contents:CI858 communication interface plus TP858 baseplate
-
Controller family:AC 800M
-
Bus protocol:ABB DriveBus
-
Communication role:Master interface
-
Transmission speed:8 Mbit/s
-
Physical connector:Optical
-
Drive capacity:Up to 24 ABB drives per CI858
-
Controller interface capacity:Up to two CI858 modules per AC 800M controller
-
Branching requirement:NDBU branching unit when more than one drive is connected
-
Power path:Supplied from controller through CEX-Bus
-
Typical 24 V consumption:200 mA
-
Hot swap:Supported
-
Line redundancy:Not provided
-
Module redundancy:Not provided
-
High Integrity controller use:Not supported
-
Operating temperature:0 to +55 °C
-
Storage temperature:-40 to +70 °C
-
Enclosure protection:IP20
-
Corrosion class:G3 to ISA 71.04
Information
- This complete DriveBus kit serves an installed AC 800M drive-control topology; its module and baseplate are selected together.
Kit boundary: Inspect both the CI858 interface and TP858 baseplate against the offered set.
Acceptance record: Verify every configured drive node and controller diagnostic after the change.
DriveBus is an optical ABB drive network running at 8 Mbit/s. ABB specifies up to 24 drives on one CI858 and up to two CI858 interfaces on one AC 800M controller. When more than one drive is attached, an NDBU branching unit forms the required logical bus with physical star connections; the count alone does not define a valid topology.
The interface supports hot swap but offers neither line nor module redundancy, and ABB does not list it for High Integrity controller use. In rolling-mill or paper-machine sectional-drive systems, restore the approved controller configuration, optical paths and node identities, then prove drive status and diagnostics before handing the line back.
-
ABB CI858K01 3BSE018135R1 technical reference
Apter Power reference with verified manufacturer data and exact-model applicability. -
ABB CI858K01 3BSE018135R1 engineering guide
Apter Power installation, configuration, diagnostic and acceptance guidance.
Platform applications: The uses below depend on the installed controller configuration and approved system design.
-
Sectional drive coordination
Connect AC 800M control to multiple ABB drives using an approved DriveBus topology. -
Rolling-mill drive systems
Carry drive communication in the controller arrangement designed for sectional mill operation. -
Paper-machine control
Support drive-group communication where the installed machine uses AC 800M DriveBus. -
Maintenance replacement
Replace the CI858/TP858 kit while retaining the configured controller and optical network identity.
Verify the CI858 module and TP858 baseplate are both present in the offered CI858K01 kit.
Follow the controller maintenance procedure before handling the module or baseplate.
Keep optical contacts clean and match each drive link to the approved topology.
Check the NDBU arrangement when more than one drive is connected.
Confirm the installed CEX-Bus allocation and approved AC 800M configuration.
Check every configured drive node, diagnostics and restart behavior before release.
Alternative Names
Technical notes
Installation relationship: The CI858 module uses TP858 on the AC 800M CEX-Bus; confirm the complete kit and host configuration.
Network boundary: DriveBus is an optical master interface; multiple-drive topology uses NDBU branching.
Technical reference: ABB CI858 product data and AC 800M Communication Interfaces data sheet, 23 September 2026.
FAQ View All FAQ
-
How should the NDBU branch path be proved after replacing CI858K01 3BSE018135R1?Compare the documented physical star with the configured logical DriveBus sequence, then check every drive node in AC 800M diagnostics. Verify one optical path at a time so a swapped branch is not hidden by a successful link at another node.
-
What does hot swap mean for CI858K01 3BSE018135R1 during maintenance?The interface is designed for hot swap, but the controller and process must still follow the approved maintenance procedure. Record drive states, isolate the affected control function as required and verify every node after insertion.
-
How can an optical DriveBus fault on CI858K01 3BSE018135R1 be isolated?Inspect the optical connectors and NDBU branch paths, then compare controller diagnostics with drive-node status. Test one documented path at a time under site procedure rather than changing several links blindly.
-
Why is CI858K01 3BSE018135R1 not a redundant communication path by itself?ABB specifies neither line nor module redundancy for CI858. Review the process response to loss of this interface and the available maintenance bypass before a live replacement.
-
What should be matched before replacing a CI858K01 3BSE018135R1 kit?Compare the CI858 and TP858 markings, controller slot and software configuration, drive-node assignment and optical connector layout with the installed assembly. Confirm both kit elements are included in the offer.
-
What can cause a drive to remain offline after CI858K01 3BSE018135R1 is fitted?A wrong optical branch, missing NDBU path, changed controller configuration or a drive-node mismatch can prevent communication. Use AC 800M diagnostics and the approved bus map to locate the affected path.
-
What evidence should be reviewed before accepting CI858K01 3BSE018135R1 in an AC 800M host?Compare the host processor identity, CEX-Bus allocation and approved engineering configuration with the installed controller record. If the controller is a High Integrity variant, stop the selection and obtain an approved system design.
-
Which records should be retained after commissioning CI858K01 3BSE018135R1?Retain both kit markings, controller slot/configuration, optical branch map, drive-node status and diagnostic results. Compare these with the pre-change baseline before releasing the machine.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
CI858K01 3BSE018135R1Product Details -
3BHE023584R1032 PPD113 B03-10-151000Product Details -
ZINT-571 3AUA0000077333Product Details -
UAD141A02 3BHE012095R0002Product Details -
TC520 3BSE001449R1Product Details -
AI830A 3BSE040662R1Product Details -
RINT-5611C 68718929Product Details -
3BHE004573R0142 UFC760BE142Product Details -
1SFB536068D1011Product Details -
YPQ110A 3ASD573001A5Product Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.