Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel

IPC704 244-704-000-042

vibro-meter IPC704 Charge-Signal Conditioner - Configuration Verification
In Stock
Ships by Friday, August 28
Fast Shipping Available

Product Describe:

vibro-meter IPC704 244-704-000-042 is a configurable charge-signal conditioner.
It conditions CA accelerometer or CP dynamic-pressure sensor charge signals.
Ordered options define filtering, integration, current/voltage output, and approvals.
The base P/N is incomplete; capture every A-I suffix before configuration or replacement.

Ask our team:

Get a quick price for: IPC704 244-704-000-042
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for IPC704 244-704-000-042

Technical specifications for IPC704 244-704-000-042

  • Manufacturer:
    Vibro-Meter
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    244-704-000-042
  • Estimated shipping dimensions:
    7.8x5.3x4.8cm
  • Weight:
    0.25 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Switzerland
  • Manufacturer:
    Meggitt SA / Parker Meggitt
  • Model:
    IPC704
  • Complete configuration:
    HOLD - A-I option code not supplied
  • Product type:
    Configurable signal conditioner / charge converter
  • Supported sensor classes:
    vibro-meter CA piezoelectric accelerometers and CP piezoelectric dynamic-pressure sensors; exact sensor and cable must be verified
  • Input signal:
    Charge-based signal from the configured piezoelectric sensor
  • Output signal:
    Current-modulated two-wire or voltage-modulated three-wire, configuration-dependent
  • Family frequency range:
    Configurable high-pass/low-pass range spanning 0.5 Hz to 20 kHz; actual ordered filters unknown
  • Transfer function:
    Factory-configurable sensitivity and units; exact value unknown without full A-I code
  • Velocity output:
    Optional integrator; presence and scaling unknown without full A-I code

Information

Information

Overview Manuals Common Applications Product Precautions
vibro-meter IPC704 244-704-000-042 is a Meggitt signal conditioner, also described in the official manuals as a charge converter, for piezoelectric machinery-monitoring measurement chains using CA accelerometers or CP dynamic-pressure sensors.
  • Manufacturer: Meggitt SA / Parker Meggitt
  • Brand: vibro-meter
  • Model: IPC704
  • Verified base P/N: 244-704-000-042

It receives the sensor's charge-based signal, applies the ordered transfer function and high-pass/low-pass filtering, optionally integrates acceleration to velocity when that factory configuration is selected, and delivers a conditioned analogue signal to an external machinery protection or condition-monitoring system. Depending on the complete A-I option code, IPC704 provides a current-modulated two-wire output for longer transmission or a voltage-modulated three-wire output for shorter transmission; the published family operating bandwidth is configurable within 0.5 Hz to 20 kHz. The incomplete base P/N does not establish the actual sensitivity, units, filters, output type, integrator or hazardous-area version of this unit. IPC704 is used with the exact CA/CP sensor, compatible low-noise sensor/extension cable, K2xx/K3xx transmission wiring, optional GSI127 galvanic-separation unit, ABA160 or ABA17x industrial housing, MA130 DIN-rail adaptor and a correctly scaled external monitor such as a documented VM600 arrangement. Official Meggitt examples place base P/N 244-704-000-042 in gas-turbine bearing/casing vibration, combustion-chamber vibration and combustor dynamic-pressure chains, but each example uses a different complete option code that must be matched to the project.

Important Notice: Read and record the complete P/N including every A-I option code from the physical IPC704 label before quoting, configuring, replacing, wiring, or selecting a monitoring channel.

Apter Power IPC704 244-704-000-042 Configuration Verification Manuals and Guides

Important Notice: The first link is the product-parameters PDF prepared only from the cited manufacturer information; the second link is the Apter Power product manual. Confirm the physical nameplate, current manufacturer documents, and host-system requirements before installation or replacement.

Gas-turbine bearing absolute vibration
Official Meggitt AE 94.3A material uses IPC704 base P/N 244-704-000-042 with CA202 accelerometers to condition bearing absolute-vibration signals; the complete option code must match that machine design.
Combustion-chamber casing vibration
Official M701F/M701G and AE 94.3A examples use the base IPC704 P/N with CA134 or CA901 accelerometers to condition casing/combustion vibration, each with different transfer and filter options.
Combustor dynamic-pressure monitoring
Official M701F/M701G and AE 94.3A examples use the base IPC704 P/N with CP237 or CP704 dynamic-pressure sensors to condition pressure-pulsation signals for monitoring/protection.
Long-distance analogue machinery-monitoring chains
A current-output IPC704 can be paired with two-wire transmission and GSI127 galvanic separation to carry high-frequency measurement signals from field sensors to a remote monitoring system, subject to the exact wiring and Ex design.
Read and follow the current Parker Meggitt documentation and host-equipment instructions before work. Verify the complete physical nameplate and system configuration.
1
Do not energize, quote or configure the IPC704 from base P/N 244-704-000-042 alone; record the complete A-I option code and the physical label first.
2
Isolate all sensor, conditioner, power, output, GSI127 and monitoring-system circuits using the site's approved electrical and machinery-protection procedure before wiring changes.
3
Follow the exact Meggitt CAxxx or CPxxx measurement-chain installation manual that matches the sensor class; do not mix vibration-chain and pressure-chain pinouts or cable arrangements.
4
Because the conductive IPC704 housing is connected to COM, electrically isolate the housing from ground exactly as instructed to avoid earth loops and incorrect measurements.
5
Maintain the documented cable shields, pair routing, separation from power wiring, enclosure entry grounding and open/connected shield ends; do not improvise a two-ended shield connection.

Technical notes

Technical notes

Verification Status: VERIFIED IPC704 BASE PART NUMBER FROM MEGGITT OFFICIAL APPLICATION FLYERS; CONFIGURATION SUFFIX A-I NOT SUPPLIED Exact Mapping: Meggitt official gas-turbine application flyers repeatedly identify IPC704 with base P/N 244-704-000-042, followed by A-I option codes. The same base number appears with different environment, transfer, sensitivity, filtering, transmission and application configurations. Therefore 244-704-000-042 verifies the product family/base hardware but does not identify one complete electrical configuration. Lifecycle Status: Superseded in the vibro-meter Energy product line: Meggitt announced in January 2019 that IPC707 was replacing IPC704. No exact Active/Classic/Limited/Obsolete phase for 244-704-000-042 is published in the cited official sources. Country Of Origin: unknown - the cited official material identifies Meggitt SA in Switzerland but does not state the country of origin of this exact unit; a corporate address is not origin evidence Dimensions: unknown for the requested incomplete configuration; the installation manual states that IPC704 has four mounting holes and that their pattern is equivalent to the replacement IPC707 pattern, but this is not a complete W x H x D specification Weight: unknown Read and record the complete P/N including every A-I option code from the physical IPC704 label before quoting, configuring, replacing, wiring, or selecting a monitoring channel. Do not select or publish an exact sensor sensitivity, transfer function, high-pass filter, low-pass filter, current/voltage output, integrator, Ex approval, power arrangement, or monitoring-system scaling from the incomplete base P/N. Verify whether the installed measurement chain uses a CAxxx accelerometer or CPxxx dynamic-pressure sensor, the exact sensor P/N and sensitivity, every cable P/N, the output transmission type, GSI127/industrial-housing arrangement and receiving monitor channel. IPC707 replaced IPC704 in the vibro-meter Energy product line in January 2019, but replacement selection still requires Parker Meggitt's IPC704-to-IPC707 conversion data and the complete IPC704 option code; do not claim a universal one-code replacement. A complete IPC704 configuration from base P/N 244-704-000-042 alone Any exact A-I suffix, sensor sensitivity, transfer gain, engineering unit, high-pass/low-pass filter, output type, integrator, supply or approval not read from the physical label IPC707-only diagnostics, BITE, SIL 2, PL c, IP40, temperature, linearity, dimensions or terminal features applied to IPC704 Universal drop-in IPC707 order code without Parker Meggitt conversion of the full IPC704 option code Compatibility with an unspecified CA/CP sensor, cable, GSI127 variant, housing or monitor channel Independent alarm, trip, digital communication, Ethernet, Modbus, PROFIBUS or PROFINET capability Dimensions, weight, country of origin or HS/customs code Current stock, warranty, lead time, calibration status or functional-safety certification of the physical unit.

FAQS

  • What is vibro-meter IPC704?
    It is a configurable Meggitt signal conditioner/charge converter for CA piezoelectric accelerometers and CP piezoelectric dynamic-pressure sensors.
  • Is 244-704-000-042 a complete IPC704 ordering number?
    No. Official Meggitt examples append A-I option codes; the base number alone does not identify one complete electrical configuration.
  • What signal enters the IPC704?
    A charge-based signal from the selected CA accelerometer or CP dynamic-pressure sensor enters through the approved low-noise sensor cable.
  • What output does IPC704 provide?
    Depending on the ordered configuration, it provides a current-modulated two-wire or voltage-modulated three-wire analogue output.
  • What frequency range does the IPC704 family cover?
    Meggitt's official sensor-system brochure states configurable high-pass and low-pass filters across 0.5 Hz to 20 kHz; the actual ordered limits require the full option code.
  • Can IPC704 produce velocity output?
    An optional integrator can provide a velocity-related output, but its presence and scaling cannot be confirmed from the incomplete base P/N.
  • Which sensors can be used?
    Meggitt documents CA piezoelectric accelerometers and CP piezoelectric dynamic-pressure sensors; the exact sensor model, sensitivity and cable must match the full IPC704 configuration.
  • Can it transmit over a long distance?
    Meggitt documents current-output, two-wire IPC704 chains with a GSI127 galvanic-separation unit for high-quality long-distance signal transmission.
  • Why must the IPC704 housing be insulated from ground?
    The manufacturer states that its conductive housing is connected to COM, so isolation from ground is required to eliminate earth loops and help ensure correct measurements.
  • Is every IPC704 suitable for a hazardous area?
    No. Standard and Ex versions were configuration choices made at ordering; use requires the full P/N, nameplate approval and exact hazardous-area installation design.
  • What replaced IPC704?
    Meggitt announced IPC707 as the fully backward-compatible replacement in January 2019, but the complete IPC704 option code is still required for correct conversion.
  • Does IPC704 make alarm or trip decisions?
    No. It conditions and transmits the measurement signal; the external machinery protection/monitoring system performs measurements, alarms, trips and diagnostics according to its configuration.
  • Which applications are officially documented?
    Meggitt application flyers document bearing absolute vibration, combustion-chamber casing vibration and combustor dynamic-pressure chains on several gas-turbine models, using different complete IPC704 configurations.
  • What must be checked before replacement?
    Verify the full A-I code, sensor and cable, current/voltage output, transfer sensitivity and units, filters, integrator, power, grounding, Ex approvals, housing, GSI127 and receiving-monitor channel scaling.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.