General Electric MIVII3000E00HI00 is an evidence-bounded requested MIV II 3000 voltage and frequency relay configuration. GE Vernova verifies the MIV II family and the MIVII3000 voltage-plus-frequency function set; the located public material does not decode the complete E00HI00 suffix.
- Requested full code: MIVII3000E00HI00
- Verified family: MIV II
- Verified function variant: MIV II 3000 voltage and frequency protection
- Protocols: Front RS232 and rear RS485, Modbus RTU
System role: MIV II 3000 combines phase and ground voltage protection with two frequency elements, metering, event functions and Modbus serial communications. Only facts stated by the cited GE Vernova material are published; sibling, successor and third-party data are not transferred. Architecture boundary: Verify the full nameplate, voltage-input range, control-power code, I/O option and communication option before wiring or setting replacement. Manufacturing is discontinued and GE recommends P94V or 350 alternatives; neither is an unconditional drop-in replacement. Before installation or replacement, verify the complete physical label, host equipment, companion hardware, wiring and approved commissioning procedure. Origin and HS code remain unpublished unless an exact manufacturer record or the physical package label establishes them.
Important Notice: Verify the complete General Electric MIVII3000E00HI00 physical label and installed-system documentation before use.
Apter Power MIVII3000E00HI00 Configuration Verification Manuals and Guides
Important Notice: The first link is the model-specific product-parameters PDF prepared only from the cited GE Vernova official evidence; the second link is the Apter Power product information manual. Confirm the physical nameplate, current GE Vernova documents, and host-system requirements before installation or replacement.
Installed-base maintenanceSupports evidence-led identification and replacement planning for General Electric MIVII3000E00HI00.
System documentationProvides a source-traceable boundary for the documented Multilin MIV II relay family configuration.
Commissioning reviewGuides identity, companion-hardware, wiring and controlled functional checks before return to service.
Migration assessmentSeparates exact-model facts from successor, sibling and family-level information.
Read and follow the exact GE Vernova documentation and host-equipment instructions before work. Verify the complete physical nameplate and system configuration.
1Verify the complete General Electric MIVII3000E00HI00 label, revision and installed-system documentation before use.
2Manufacturing is discontinued and GE recommends P94V or 350 alternatives; neither is an unconditional drop-in replacement.
3De-energize the equipment and follow the site's approved electrical and process-safety procedure before disturbing hardware or wiring.
4Back up controller, drive, network and configuration data before replacement, migration or firmware work.
5Verify every companion module, cable, connector, termination and power source from approved drawings.
6Do not copy electrical, communication, mechanical or lifecycle values from a related model or successor.
7Perform a documented functional test and confirm diagnostics, alarms and fail-state behavior after work.
8Origin and HS code remain unpublished unless an exact manufacturer record or the physical package label establishes them.