Technical specifications for KPCI-PIO32IOA
-
Manufacturer:TEKTRONIX
-
Product Category:General Automation
-
Spare Part Number:KPCI-PIO32IOA
-
Weight:0.12 kg
-
Tariff Code:8537101190
-
Product type:32-Line Optically Isolated Digital I/O Board
-
System context:Keithley PCI data-acquisition platform
-
Digital I/O:32 isolated lines: 16 inputs and 16 outputs
-
Voltage range:Up to 60 VDC or 30 Vrms
-
Input logic high:Greater than |±2.5 V|
-
Input logic low:Less than |±1.0 V|
-
Input response:0.6 ms typical; 1.0 ms maximum
-
Selectable input filter:175 ms time constant
-
Output type:Optically isolated N.O. Form A MOSFET switches
-
Maximum load current:350 mA
-
Output on-resistance:3.5 Ω typical; 4 Ω maximum
-
Relay on time:1.0 ms typical; 3.5 ms maximum
-
Relay off time:80 µs typical; 200 µs maximum
-
Leakage current:316 nA typical; 2 µA maximum
-
Isolation:60 V channel-to-channel and channel-to-chassis
-
Board power:500 mA maximum; an additional 1 A can be drawn from pin 1 at +5 V
-
Operating temperature:0 to 50 °C
-
Storage temperature:-20 to 70 °C
-
Humidity:0–80% at 35 °C, non-condensing
-
Board connector:3M N10236-52B2VC
-
Mating connectors:3M 10136-6000EC or 10136-3000VE
-
Input banks:IP0–IP7 and IP8–IP15
-
Output banks:OP0–OP7 and OP8–OP15
-
Manufacturer board dimensions:18.1 × 10.8 × 1.9 cm
-
Leakage-current test condition:60 VDC, 50 °C and 30% RH
-
External interrupt inputs:IP6 interrupt input; IP7 interrupt enable
Information
- KPCI-PIO32IOA occupies a defined service position in the Keithley PCI data-acquisition platform; approval depends on the complete marking and installed boundary.
Input timing: 0.6 ms typical response with a 1.0 ms maximum.
Output switching: 350 mA maximum load with 3.5 Ω typical on-resistance.
Within the Keithley PCI data-acquisition platform, evaluate KPCI-PIO32IOA together with its carrier, terminals, cables and applicable project or hardware settings. Preserve the as-found interface map and revision evidence; a mechanically similar item is not automatically equivalent.
Commissioning KPCI-PIO32IOA should progress from identity and connection checks to controlled power-up, diagnostics and functional proof. Keep final status, test conditions and unresolved exceptions in the handover record.
-
KPCI-PIO32IOA Technical Reference
Apter Power technical reference - PDF, 5 pages. Exact identity, evidence boundary, installed-system decisions and engineering questions. -
KPCI-PIO32IOA Installation & Commissioning Guide
Apter Power engineering guide - PDF, 5 pages. Replacement sequence, interface checks, commissioning, fault isolation and acceptance record.
Compatibility boundary: Match the complete marking, hardware execution and installed interfaces before replacement.
-
Installed-system replacement
Compare the exact code, host position and connected interfaces with the removed item. -
Planned maintenance
Capture the as-found label, indications and configuration before disturbing the installation. -
Controlled commissioning
Restore documented connections and prove the intended signal, communication or control response. -
Spare qualification
Keep revision, configuration and acceptance evidence with the spare-part record.
Check every token in KPCI-PIO32IOA against the offered label and approved record.
Follow the site procedure for stored energy, field power and electrostatic handling.
Photograph and label carriers, terminals, cables and keying before removal.
Archive applicable Keithley PCI data-acquisition platform settings before replacement.
Check connectors, terminal blocks, carriers and cable condition before blaming the module.
Use an approved functional test and retain as-left diagnostic and acceptance evidence.
Alternative Names
Technical notes
Evidence scope: The exact-model official data sheet states the channel count, I/O electrical limits, timing, isolation, environment and connector information used here.
Installation boundary: The exact installed carrier, terminals, cables and project configuration remain site-specific.
Technical reference: Keithley KPCI-PIO32IOA and KPCI-PDISO8A official data sheet
FAQ View All FAQ
-
How should KPCI-PIO32IOA be identified before replacement?Compare the complete KPCI-PIO32IOA marking, visible revision, installed position and the documented 32-line optically isolated digital i/o board role. Do not approve a shortened family reference.
-
What evidence should be recorded before removing KPCI-PIO32IOA?Photograph the complete label, connectors, cable routes, status indications and host position for KPCI-PIO32IOA; retain the current Keithley PCI data-acquisition platform record.
-
How should the interfaces for KPCI-PIO32IOA be checked?Map every connector, terminal and cable used by KPCI-PIO32IOA to the as-found record, then verify keying, shielding and interface ownership before reconnection.
-
What configuration boundary matters when commissioning KPCI-PIO32IOA?Use the approved Keithley PCI data-acquisition platform configuration for KPCI-PIO32IOA. Physical fit alone does not establish electrical, firmware or project equivalence.
-
How can a suspected KPCI-PIO32IOA fault be separated from an external fault?Check host power, mating hardware, field wiring and the applicable signal or communication path before controlled substitution of KPCI-PIO32IOA.
-
What should be verified after installing KPCI-PIO32IOA?Confirm normal indications, interface continuity and the intended 32-line optically isolated digital i/o board response for KPCI-PIO32IOA in an approved test state.
-
Can KPCI-PIO32IOA be replaced by a similar-looking unit?Appearance is not an equivalence criterion for KPCI-PIO32IOA; compare the complete order code, revision, connectors and installed configuration.
-
What handover record is appropriate after work on KPCI-PIO32IOA?Retain the offered and removed KPCI-PIO32IOA markings, connection photographs, configuration evidence, diagnostics, functional-test results and open exceptions.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
KPCI-PIO32IOAProduct Details -
KFD2-SOT3-EX1.LBProduct Details -
EVS9324-EPProduct Details -
M-FAST SFP-MM/LCProduct Details -
M00279-3266-140Product Details -
G128-0001Product Details -
SYS68K-CPU-30BE16-REV-3Product Details -
PR6423/018-140 CON021Product Details -
PR6424/014-140 CON021Product Details -
E-ME-T-01HProduct Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.