Match the complete marking
Include 505-6660B and the visible revision or assembly identity in your enquiry. Keep the complete reference on the quotation.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 505-6660B with the installed equipment and applicable Siemens documentation.
Technical specifications for 505-6660B
-
Manufacturer:Siemens
-
Product Category:PLC Systems
-
Spare Part Number:505-6660B
-
Weight:1.48 kg
-
Tariff Code:8537101190
-
Product family:SIMATIC 505 power supply
-
Manufacturer order form:PPX:505-6660-B
-
AC input range 1:85-132 V AC
-
AC input range 2:170-264 V AC
-
Rated output power:60 W
-
Galvanic isolation:Yes
-
Short-circuit protection:Yes
-
Redundant supply capability:Yes
-
Input selector:110 V / 220 V setting on -B execution
Information
- Siemens 505-6660B. For a 505-6660B exchange, record the existing input-selector setting, rack load and any redundant-supply wiring before isolating the base.
Manufacturer order form: PPX:505-6660-B
AC input range 1: 85-132 V AC
AC input range 2: 170-264 V AC
The -B unit has its own 110 V / 220 V input selector arrangement. The site electrician must set the selector to the actual supply before energizing the rack.
The supply mates with the 505 backplane and is secured by top and bottom bezel screws. Rack loading and any redundancy arrangement must follow the installed system design.
-
Siemens 505-6660B technical reference
Original manufacturer excerpt - PDF, 1 page. Relevant manufacturer specifications and product identification. -
Siemens 505-6660B installation guide
Prepared by Apter Power - PDF, 5 pages. Installed-system review, configuration checks, commissioning and handover.
Application scope: Use it for supply replacement or supported redundant-rack arrangements after matching the exact -B execution and input-voltage setting.
-
SIMATIC 505 rack power
The 505-6660B supplies a documented SIMATIC 505 base and its installed modules. -
AC input configuration
The -B selector supports the documented 110 V or 220 V setting for the corresponding AC input range. -
Rack power budget
The 60 W rated output must cover the actual rack module load. -
Supported redundancy
A redundant supply arrangement is applicable only where the installed 505 rack design provides for it.
Remove AC input before handling the rack power supply.
Check the -B selector against the actual input range before energizing.
Seat the backplane connection and tighten the bezel screws to the Siemens manual torque range.
Confirm that connected modules remain within the 60 W supply output budget.
Apply only the rack-specific documented redundant supply wiring.
Check supply indicators and PLC behavior after the module is secured and the rack is energized.
Alternative Names
Technical notes
Installation relationship: Match the -B input selector to the available 110 V or 220 V supply before inserting or energizing the module.
Protection: The catalog lists isolation and short-circuit protection; rack loading and redundant operation require the installed 505 configuration.
Technical reference: Siemens SIMATIC 505 ST40 Catalog; SIMATIC 545/555/575 System Manual, PPX:505-8201-3.
FAQ View All FAQ
-
Which system uses 505-6660B?It is a power-supply unit for the Siemens SIMATIC 505 rack family.
-
What are the AC input ranges for 505-6660B?Siemens specifies 85-132 V AC and 170-264 V AC for the 505-6660-A/B power-supply execution.
-
What is the rated output power of 505-6660B?The Siemens ST40 catalog gives 60 W for the 505-6660-A/B supply.
-
Does 505-6660B provide galvanic isolation?Yes. The Siemens catalog marks galvanic isolation for the 505-6660-A/B power supply.
-
Does 505-6660B include short-circuit protection?Yes. Siemens lists short-circuit protection for this supply execution.
-
Can 505-6660B be used in a redundant supply arrangement?The Siemens catalog marks the 505-6660-A/B as redundant-capable; apply the rack’s documented wiring and redundancy scheme.
-
How is line voltage selected on 505-6660B?The Siemens system manual shows a dedicated 110 V / 220 V selector arrangement for the -B version; set it before energizing.
-
What should be checked when installing 505-6660B?Verify the input selection, supply isolation, backplane engagement and top/bottom bezel screw torque against the SIMATIC 505 manual.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.