Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for 10208/2/1
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 10208/2/1

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • Spare Part Number:
    10208/2/1
  • Estimated shipping dimensions:
    2x18.8x12.7cm
  • Weight:
    0.22 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Output channels:
    10
  • Output type:
    Potential-free relay contact
  • Contact arrangement:
    Common and normally open
  • Maximum current:
    2 A
  • Maximum voltage:
    30 VAC / 36 VDC
  • Maximum switched power:
    100 W / 1000 VA
  • Power requirement:
    5 VDC 25 mA; 24 VDC 120 mA
  • Minimum software version:
    3.00
  • Space requirement:
    4 HP, 3U
  • Approvals:
    CE, TÜV, UL
  • Key coding:
    A9, C17

Information

Overview Manuals Common Applications Product Precautions
Honeywell 10208/2/1 provides ten controlled contact outputs for FSC applications, combining watchdog de-energization, defined contact limits and direct common/normally-open field connections.
  • 10 potential-free contacts
  • 2 A maximum current
  • 36 VDC maximum contact voltage
  • Watchdog de-energization

Use Honeywell 10208/2/1 only with the documented system, field interface and approved commissioning record for the installed application.

Important Notice: Confirm the complete 10208/2/1 identity, companion hardware and wiring condition; do not substitute a similar code without an engineering review.

Honeywell 10208/2/1 Manuals & Downloads
Honeywell 10208/2/1 Official Technical Reference Excerpt (PDF)Honeywell 10208/2/1 Installation & Commissioning Guide (PDF)

The Official Technical Reference Excerpt consolidates the selected Honeywell manual pages and exact-model technical data; the Installation & Commissioning Guide organizes identity control, isolation, interface checks, functional testing and acceptance records.

Lamp switching
Controls compatible resistive indication loads within the contact limits.
Solenoid switching
Drives compatible inductive loads when an external suppression diode is installed.
FSC discrete actuation
Provides ten relay-contact outputs for non-fail-safe field functions.
Watchdog shutdown response
Returns all relays to the de-energized state when the watchdog switches off.
Apply these controls specifically to Honeywell 10208/2/1 before isolation, replacement, reconnection and final release.
1
Confirm the complete 10208/2/1 code and key positions A9/C17 before insertion.
2
Do not use these untested relay outputs for fail-safe applications.
3
Keep every load within the 2 A, 30 VAC/36 VDC and switched-power limits.
4
Install an external suppression diode across each inductive load.
5
Record all ten common and normally open conductors before disconnecting the module.
6
Verify FSC software version 3.00 or later for the documented module execution.
7
Restore the 5 VDC and 24 VDC supplies only after checking connector engagement.
8
Test every channel and confirm watchdog de-energization before releasing the system.

Alternative Names

10208/2/1

Technical notes

Record the complete model identity, installed system position, companion hardware, field wiring and configuration before service. Use the exact-model limits and acceptance checks shown in the manuals for restoration.

FAQ View All FAQ

  • How many outputs does Honeywell 10208/2/1 provide?
    It provides ten potential-free relay contact outputs.
  • What contact arrangement is used by Honeywell 10208/2/1?
    Each channel provides a common terminal and a normally open terminal.
  • What current can Honeywell 10208/2/1 switch?
    The maximum contact current is 2 A.
  • What voltage limit applies to Honeywell 10208/2/1?
    The documented maximum is 30 VAC or 36 VDC.
  • Can Honeywell 10208/2/1 be used for fail-safe outputs?
    No. Its outputs are not tested for fail-safe applications.
  • What is required when Honeywell 10208/2/1 drives a solenoid?
    An external suppression diode must be mounted across the inductive load.
  • How does Honeywell 10208/2/1 respond when the FSC watchdog switches off?
    All module relays de-energize.
  • Which software baseline applies to Honeywell 10208/2/1?
    The data sheet specifies software version 3.00 or later.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.