Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for 10100/2/1
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 10100/2/1

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Module function:
    Horizontal bus driver
  • Rack space:
    4 HP; 3U
  • Approvals:
    CE; TUV; UL
  • Minimum software:
    3.00
  • A1 cable duty:
    Non-redundant I/O
  • A21 cable duty:
    Redundant I/O; one rack per HBD
  • A22 cable duty:
    Redundant I/O; two racks per HBD
  • A1/A21 power:
    5 Vdc; 35 mA
  • A22 power:
    5 Vdc; 65 mA
  • Ripple:
    Less than 50 mV p-p

Information

Overview Manuals Common Applications Product Precautions
Honeywell 10100/2/1 is the FSC horizontal bus driver that links the vertical bus from the Central Part to an I/O rack horizontal bus.
  • Transfers the vertical FSC bus into an I/O rack horizontal bus.
  • Supports non-redundant I/O through the A1 flat cable.
  • Supports redundant one-rack I/O through the A21 flat cable.
  • Supports redundant two-rack I/O through the A22 flat cable.

The cable execution changes both redundancy topology and current demand. Preserve the approved A1, A21 or A22 selection and rack address.

Important Notice: Verify the complete 10100/2/1 identity, installed system position, connections and controlled functional result before release.

Honeywell 10100/2/1 Manuals & Downloads
Honeywell 10100/2/1 Official Manufacturer Excerpt (PDF)Honeywell 10100/2/1 Installation & Commissioning Guide (PDF)
The first document records verified technical evidence. The second organizes controlled preparation, installation, commissioning and handover.
Non-redundant FSC I/O rack
Transfers the vertical FSC bus into an I/O rack horizontal bus.
Redundant single-rack I/O
Supports non-redundant I/O through the A1 flat cable.
Redundant dual-rack I/O
Supports redundant one-rack I/O through the A21 flat cable.
FSC rack address distribution
Supports redundant two-rack I/O through the A22 flat cable.
Honeywell 10100/2/1 installation checks must preserve the exact identity, system assignment and witnessed acceptance record.
1
Confirm 10100/2/1 and the installed rack address.
2
Identify whether the installation uses A1, A21 or A22.
3
Record the vertical bus and horizontal bus routing.
4
Isolate rack power before disturbing the flat cable.
5
Protect DIN 41612 contacts from ESD and mechanical damage.
6
Restore the documented address-selection jumper pattern.
7
Verify horizontal-bus communication for every served rack.
8
Retain the final rack and redundancy acceptance record.

Technical notes

The cable execution changes both redundancy topology and current demand. Preserve the approved A1, A21 or A22 selection and rack address.

FAQ View All FAQ

  • What system function does Honeywell 10100/2/1 perform?
    It is the FSC horizontal bus driver between the Central Part vertical bus and an I/O rack horizontal bus.
  • Which cable makes Honeywell 10100/2/1 a non-redundant HBD?
    The A1 flat cable is specified for non-redundant I/O.
  • How is Honeywell 10100/2/1 used with one redundant I/O rack?
    Use the A21 flat cable for one rack per HBD.
  • How is Honeywell 10100/2/1 used with two redundant I/O racks?
    Use the A22 flat cable for two racks per HBD.
  • What supply demand applies to Honeywell 10100/2/1 with A22?
    The data sheet specifies 5 Vdc at 65 mA.
  • How is the rack address associated with Honeywell 10100/2/1 selected?
    RA0 through RA3 jumpers on the documented rack-address module set the HBD address.
  • What physical format is documented for Honeywell 10100/2/1?
    The module requires 4 HP by 3U and uses a DIN 41612 type-F rack connector.
  • What proves Honeywell 10100/2/1 service after replacement?
    Verify the selected cable topology, rack address and communication to every served I/O rack.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.