Technical specifications for 6SL3351-1AE37-5BA1
-
Manufacturer:Siemens
-
Product Category:Servo Drives
-
Spare Part Number:6SL3351-1AE37-5BA1
-
Estimated shipping dimensions:37.4x27x9.5cm
-
Weight:3.1 kg
-
Tariff Code:85049090
-
Counliy of origin:Germany
-
Product type:Replacement power block
-
Supply system:3 AC
-
Voltage range:380-480 V
-
Line frequency:50/60 Hz
-
Rated current:745 A
-
Power section:Rectifier and U phase
-
Module finish:Painted
-
Busbar finish:Nickel-plated
-
Export classification:AL:N / ECCN:EAR99H
-
Quantity unit:1 piece
Information
- Combines the rectifier power section with the U-phase inverter section for the specified drive execution
- Carries the documented 745 A conversion path for a 380-480 V three-phase power module
- Retains painted power assemblies in the identified replacement configuration
- Provides nickel-plated busbar interfaces for the specified power interconnections
6SL3351-1AE37-5BA1 is installed with matching SINAMICS AC Drive/Power Module chassis, documented rectifier and U-phase busbar positions, approved gate-drive and control connections, installed cooling and protective-conductor arrangement in the approved SINAMICS AC Drive/Power Module arrangement.
Discharge the drive DC link and document the incoming rectifier and U-phase connections before exchanging 6SL3351-1AE37-5BA1. Restore busbar hardware, control interfaces, cooling and protective bonding exactly to the approved drive arrangement.
Important Notice: Confirm 6SL3351-1AE37-5BA1 and the rectifier/U-phase position from the physical marking before removal. Preserve the documented connections and complete the controlled commissioning checks before service.
Alternative Names
Technical notes
FAQ View All FAQ
-
Which power sections are contained in 6SL3351-1AE37-5BA1?It is the Siemens replacement power block for the rectifier and U-phase sections of the specified AC Drive/Power Module.
-
Which mains execution is specified for 6SL3351-1AE37-5BA1?The matching drive execution is 380-480 V three-phase at 50/60 Hz with a 745 A rating.
-
What isolation sequence applies before replacing 6SL3351-1AE37-5BA1?Isolate incoming power, secure the drive against reconnection and prove the DC link discharged before touching the rectifier or phase connections.
-
Which conductors must be identified before removing 6SL3351-1AE37-5BA1?Identify incoming phases, DC-link conductors, U-phase output, gate-drive connections, sensors and protective bonding.
-
How should the nickel-plated busbars on 6SL3351-1AE37-5BA1 be handled?Keep contact faces clean, inspect insulators and reuse only the documented fastening arrangement for the drive execution.
-
Can 6SL3351-1AE37-5BA1 substitute for a V/W-phase power block?No; this article is identified for the rectifier and U-phase function and must remain in the matching position.
-
How is 6SL3351-1AE37-5BA1 commissioned after installation?Restore the approved power connections, energize in a controlled sequence and verify rectifier diagnostics and U-phase output response.
-
Which evidence should be saved after servicing 6SL3351-1AE37-5BA1?Save the identity, phase and busbar record, insulation and connection checks, diagnostic state and controlled test result.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.