Match the complete marking
Provide the complete Siemens 6SL3055-0AA00-5AA3 marking.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 6SL3055-0AA00-5AA3 with the installed equipment and applicable Siemens instructions.
Technical specifications for 6SL3055-0AA00-5AA3
-
Manufacturer:Siemens
-
Product Category:PLC Systems
-
Spare Part Number:6SL3055 0AA00 5AA3
-
Weight:0.55 kg
-
Tariff Code:8537101190
-
Electronics supply:24 V DC, 20.4–28.8 V
-
Current without encoder system:≤0.20 A
-
Current with encoder system:≤0.35 A
-
Power loss:≤10 W
-
Resolver transformation ratio:0.5
-
Excitation voltage:4.1 V RMS, not parameterizable
-
Excitation frequency for 5AA3:5–16 kHz
-
Secondary-track amplitude threshold:1 V RMS
-
Maximum encoder cable length:130 m
-
Protection:IP20 or IPXXB
-
PE connection:M4 screw, 1.8 N·m
-
Example maximum evaluation speed:120000 rpm for 2-pole resolver at 8 kHz / 125 µs
Information
- Siemens 6SL3055-0AA00-5AA3 converts resolver feedback into the drive system feedback path while supplying the specified excitation and supervising signal amplitude.
Drive integration: Transfer the evaluated feedback into the configured drive topology.
Compatibility boundary: Resolver characteristics and execution-specific evaluation settings govern suitability.
Resolver transformation ratio and winding characteristics determine electrical compatibility. The offered hardware execution must be considered together with the drive's evaluation settings.
Cabling, shielding and protective earth complete the installed interface. Position and speed feedback should be interpreted only after the physical wiring and motor configuration agree.
6SL3055-0AA00-5AA3 Official Technical Excerpt
Siemens 6SL3055-0AA00-5AA3: original manufacturer technical information covering the specified interfaces and operating limits. PDF · 8 pages.6SL3055-0AA00-5AA3 Installation & Verification Guide
Apter Power guide covering resolver identity, supply and windings, timing and cable, earth and feedback, axis acceptance. PDF · 5 pages.
Application boundary: The exact hardware execution must suit the resolver characteristics and drive evaluation settings.
Resolver motor feedback
Compatible resolver signals provide position and speed feedback to the drive system.Cabinet sensor integration
The SMC10 is installed inside the controlled electrical cabinet with the prescribed supply and earth.Feedback conversion
Excitation and secondary-track evaluation form the resolver-to-drive signal path.Compatible drive evaluation
Resolver feedback is usable only when the sensor-module execution, motor data and evaluation settings agree.
Place the drive and mechanical axis in their approved maintenance state. Account for holding loads and possible motion before disconnecting resolver feedback or altering the drive topology.
Compare resolver resistance and inductance with the permitted evaluation conditions. Retain the 0.5 transformation-ratio requirement and the fixed excitation-voltage behavior when assessing a replacement resolver.
Trace the full cable route and connector assignment, keeping excitation and secondary signals correctly paired. Check shielding, continuity and mechanical condition within the 130 m cable limit using the approved procedure.
Restore resolver pole count, motor data and the intended sensor-module topology. Review the evaluation-speed boundary for the actual sampling interval before enabling motion.
Record resolver identity, supply and cable checks and the final feedback test. Restore normal drive operation only after the electrical feedback path and the mechanical response agree with the commissioned design.
Use the approved low-risk commissioning procedure to compare direction, position and speed feedback. Observe amplitude-related diagnostics and resolve wiring or scaling errors before releasing the axis to normal duty.
Alternative Names
Technical notes
Operating boundary: Resolver ratio, windings, pole count and evaluation timing jointly determine compatibility.
Integration details: Restore the 5AA3 excitation boundary, cable shielding and configured motor feedback data.
FAQ View All FAQ
-
Why does a matching connector not prove resolver compatibility with 6SL3055-0AA00-5AA3?Transformation ratio, winding characteristics and excitation conditions must also match. Compare those electrical requirements before accepting mechanical connection as sufficient.
-
Can the excitation voltage of 6SL3055-0AA00-5AA3 be adjusted to accommodate an arbitrary resolver?The specified excitation behavior is fixed. Select a compatible resolver rather than assuming that drive configuration can compensate for an incompatible winding arrangement.
-
How does resolver pole count affect feedback interpretation by 6SL3055-0AA00-5AA3?It relates electrical resolver cycles to mechanical motion. Restore the correct pole-count and motor configuration so position and speed are interpreted consistently.
-
Why should an older SMC10 execution not be assumed equivalent to 6SL3055-0AA00-5AA3?Execution-dependent evaluation conditions, including the sampling range, differ. Compare the exact hardware and retained settings before transferring a previous configuration unchanged.
-
What should be checked when 6SL3055-0AA00-5AA3 reports an amplitude-related fault?Inspect excitation and secondary winding connections, cable continuity and the resolver's permitted electrical characteristics. Diagnose the field path before concluding that the sensor module has failed.
-
Does staying within the cable-length limit guarantee reliable feedback to 6SL3055-0AA00-5AA3?No. Pin assignment, shielding and electrical cable condition remain important. Evaluate the complete route and resolver interface rather than checking length alone.
-
How can a direction error be found during commissioning of 6SL3055-0AA00-5AA3?With the axis secured for controlled testing, compare known mechanical movement with reported position and speed direction. Resolve winding assignment or configuration errors before normal motion.
-
Why must protective earthing be restored before testing 6SL3055-0AA00-5AA3 under drive operation?Earthing belongs to the specified cabinet installation and must not be treated as an optional diagnostic connection. Restore it through the approved procedure before enabling the associated drive.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.