6GT2002-0ED00

PROFIBUS RFID Communication Module
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Siemens 6GT2002-0ED00 connects compatible identification readers to PROFIBUS DP-V1. The ASM 456 basic module provides two reader interfaces and uses a separately selected bus connection block.
  • Manufacturer part number
    6GT2002-0ED00
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    21cm x 6cm x 3cm
  • Country of Origin
    USA
Get a quick price for 6GT2002-0ED00
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete 6GT2002-0ED00 reference, label photographs and required quantity. Check the basic-module identity, selected connection block, reader ports and address setting.

  • 1

    Confirm the offer

    Review the offered 6GT2002-0ED00 execution, condition and included items. Confirm basic module, connection block, reader cables and terminators as separately quoted in the quotation.

  • 2

    Arrange dispatch

    Swift global dispatch. Confirm quantity, dispatch date and delivery details for 6GT2002-0ED00 in the quotation.

  • Match the complete marking

    Match the complete Siemens 6GT2002-0ED00 marking and actual installed configuration. Check the basic-module identity, selected connection block, reader ports and address setting.

  • Check the offered item before ordering

    Compare offered-unit photographs, interfaces and included items with the installed 6GT2002-0ED00 and its applicable installation requirements.

Technical specifications for 6GT2002-0ED00

  • Manufacturer:
    Siemens
  • Product Category:
    General Automation
  • Spare Part Number:
    6GT2002-0ED00
  • Weight:
    0.2 kg
  • Tariff Code:
    8537101190
  • Reader interfaces:
    2
  • Reader interface electrical type:
    RS422
  • Reader connector:
    M12, 8-pin
  • PROFIBUS protocol:
    DP-V1, acyclic
  • PROFIBUS data rate:
    9.6 kbit/s–12 Mbit/s
  • Serial rate:
    115.2 kbit/s maximum
  • Supply range:
    20–30 V DC
  • Current without connected devices:
    80 mA typical at 24 V
  • Maximum total current:
    850 mA
  • Operating temperature:
    0–55 °C

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Siemens 6GT2002-0ED00 supports machine-level identification by moving reader transactions through an acyclic PROFIBUS communication path, reducing the need to place large identification payloads in the cyclic process image.
Reader transactions: Direct addressing or supported file handling
Integration choice: Match the GSD and controller-side function interface
Modular connection: Select the required PROFIBUS and power block
The basic module and connection block form the installed communication unit. ECOFAST and M12/7/8-inch connection options require the matching hardware and cable arrangement; the basic module alone does not define every external connector.

The two reader ports supply power as well as communication. Their available current limits the usable combination of readers: when one reader requires more than 400 mA, only one reader may be operated on the module.

ASM 456 uses acyclic DP-V1 transactions and supports the applicable identification functions. Preserve the GSD, address, reader protocol and controller function-block interface, then test a complete identification transaction at each intended reading point.
Controller platform reference: ASM 456 PROFIBUS DP-V1 identification system. Follow the applicable installation instructions and approved design.
Technical and service documents for Siemens 6GT2002-0ED00, covering the applicable hardware arrangement and engineering verification.
Original manufacturer pages retain their technical context. Use the Apter Power guide with the applicable manufacturer instructions and approved installation design.
System and supply context: Siemens 6GT2002-0ED00 serves the ASM 456 PROFIBUS DP-V1 identification system arrangement. Evaluate the full connected signal or control path when selecting companion hardware.

Application scope: The applications below describe the installed measurement or control path. Select compatible companion equipment; accessories are included only when expressly itemized.
Prepare Siemens 6GT2002-0ED00 for its configured installation using these checks.
Capture the identification topology

Record the basic module, connection block, PROFIBUS address, GSD and controller function interface. Associate each reader cable with its reading point and supported reader family.

Check reader and power selection

Review the total supply load and each reader current. Apply the single-reader restriction for a reader above 400 mA, and verify the selected power and PROFIBUS connection block.

Restore the field connections

Follow the identification-system installation procedure with the process secured. Reconnect the labelled readers, power and bus connections, preserving address and termination.

Validate complete transactions

Use a known target at each reading point and exercise the actual read or write command. Review command completion, returned data and diagnostic response at the controller.

Test recovery at the machine

Perform the approved reader or bus interruption test and observe recovery. Record the final GSD, function interface, reader assignments and transaction results before releasing production tracking.

Configuration handover

Retain the final 6GT2002-0ED00 identity, tested settings and accepted channel or system response for subsequent maintenance.

Alternative Names

Siemens 6GT2002-0ED00

Technical notes

Reader power budget: Two physical ports do not guarantee that two high-current readers can operate together. Apply the single-reader restriction when reader current exceeds 400 mA.

Acyclic transaction handling: The controller must manage command completion, data validity and error responses for DP-V1 transactions. A healthy bus link alone does not prove a successful transponder operation.

Protocol distinction: ASM 456 and RF160C use different communication modes and software interfaces. Preserve the installed protocol and function-block arrangement during replacement.

FAQ View All FAQ

  • Why can two connected readers exceed the usable configuration of 6GT2002-0ED00?
    The reader power budget matters as well as the port count. If a reader needs more than 400 mA, only one reader may be operated on the module.
  • Can a DP-V0 controller interface be reused unchanged with 6GT2002-0ED00?
    ASM 456 uses DP-V1 acyclic transactions. Confirm master support and the matching function interface rather than assuming cyclic data exchange is equivalent.
  • What must be retained when changing the connection block of 6GT2002-0ED00?
    Preserve the bus address, power arrangement, PROFIBUS connection method and termination required by the installed topology.
  • How does 6GT2002-0ED00 avoid placing large tag transfers entirely in the cyclic PROFIBUS data path?
    Identification commands and data are handled through acyclic DP-V1 communication. The controller must still manage transaction completion and fault responses.
  • Why can a healthy bus connection coexist with failed reads through 6GT2002-0ED00?
    Reader power, reader protocol, tag position and application command handling remain separate dependencies. Test the full reader-to-controller transaction.
  • When is file-name access appropriate with 6GT2002-0ED00?
    Use it only with the supported identification system and MOBY file-handler configuration. Direct-address and file-based access require the corresponding controller interface.
  • Which check prevents a replacement 6GT2002-0ED00 from reporting data for the wrong reading point?
    Verify each physical reader port against its controller assignment, then present a known target separately to each reading point.
  • How should communication recovery through 6GT2002-0ED00 be validated?
    Interrupt and restore the approved test path, observe diagnostics and verify that the application distinguishes fresh completed transactions from stale data.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.