Match the complete marking
Match the complete Siemens 6GT2002-0ED00 marking and actual installed configuration. Check the basic-module identity, selected connection block, reader ports and address setting.
-
Check the offered item before ordering
Compare offered-unit photographs, interfaces and included items with the installed 6GT2002-0ED00 and its applicable installation requirements.
Technical specifications for 6GT2002-0ED00
-
Manufacturer:Siemens
-
Product Category:General Automation
-
Spare Part Number:6GT2002-0ED00
-
Weight:0.2 kg
-
Tariff Code:8537101190
-
Reader interfaces:2
-
Reader interface electrical type:RS422
-
Reader connector:M12, 8-pin
-
PROFIBUS protocol:DP-V1, acyclic
-
PROFIBUS data rate:9.6 kbit/s–12 Mbit/s
-
Serial rate:115.2 kbit/s maximum
-
Supply range:20–30 V DC
-
Current without connected devices:80 mA typical at 24 V
-
Maximum total current:850 mA
-
Operating temperature:0–55 °C
Information
- Siemens 6GT2002-0ED00 supports machine-level identification by moving reader transactions through an acyclic PROFIBUS communication path, reducing the need to place large identification payloads in the cyclic process image.
Integration choice: Match the GSD and controller-side function interface
Modular connection: Select the required PROFIBUS and power block
The two reader ports supply power as well as communication. Their available current limits the usable combination of readers: when one reader requires more than 400 mA, only one reader may be operated on the module.
ASM 456 uses acyclic DP-V1 transactions and supports the applicable identification functions. Preserve the GSD, address, reader protocol and controller function-block interface, then test a complete identification transaction at each intended reading point.
6GT2002-0ED00 Original Technical Excerpt
Siemens ID 10, Communication Modules, 2016. Selected original pages retain the relevant technical tables and interface context. PDF · 3 pages.6GT2002-0ED00 Installation & Verification Guide
Apter Power field guide covering capture the identification topology, check reader and power selection, restore the field connections, validation and handover. PDF · 5 pages.
Application scope: The applications below describe the installed measurement or control path. Select compatible companion equipment; accessories are included only when expressly itemized.
Conveyor identification
Transfer tag data at a moving product identification point.Assembly-line tracking
Associate process operations with the identified carrier or component.Machine-level reader connection
Install compatible readers through the selected field connection block.Optical-code integration
Use supported optical-reader devices in the configured identification architecture.
Record the basic module, connection block, PROFIBUS address, GSD and controller function interface. Associate each reader cable with its reading point and supported reader family.
Review the total supply load and each reader current. Apply the single-reader restriction for a reader above 400 mA, and verify the selected power and PROFIBUS connection block.
Follow the identification-system installation procedure with the process secured. Reconnect the labelled readers, power and bus connections, preserving address and termination.
Use a known target at each reading point and exercise the actual read or write command. Review command completion, returned data and diagnostic response at the controller.
Perform the approved reader or bus interruption test and observe recovery. Record the final GSD, function interface, reader assignments and transaction results before releasing production tracking.
Retain the final 6GT2002-0ED00 identity, tested settings and accepted channel or system response for subsequent maintenance.
Alternative Names
Technical notes
Reader power budget: Two physical ports do not guarantee that two high-current readers can operate together. Apply the single-reader restriction when reader current exceeds 400 mA.
Acyclic transaction handling: The controller must manage command completion, data validity and error responses for DP-V1 transactions. A healthy bus link alone does not prove a successful transponder operation.
Protocol distinction: ASM 456 and RF160C use different communication modes and software interfaces. Preserve the installed protocol and function-block arrangement during replacement.
FAQ View All FAQ
-
Why can two connected readers exceed the usable configuration of 6GT2002-0ED00?The reader power budget matters as well as the port count. If a reader needs more than 400 mA, only one reader may be operated on the module.
-
Can a DP-V0 controller interface be reused unchanged with 6GT2002-0ED00?ASM 456 uses DP-V1 acyclic transactions. Confirm master support and the matching function interface rather than assuming cyclic data exchange is equivalent.
-
What must be retained when changing the connection block of 6GT2002-0ED00?Preserve the bus address, power arrangement, PROFIBUS connection method and termination required by the installed topology.
-
How does 6GT2002-0ED00 avoid placing large tag transfers entirely in the cyclic PROFIBUS data path?Identification commands and data are handled through acyclic DP-V1 communication. The controller must still manage transaction completion and fault responses.
-
Why can a healthy bus connection coexist with failed reads through 6GT2002-0ED00?Reader power, reader protocol, tag position and application command handling remain separate dependencies. Test the full reader-to-controller transaction.
-
When is file-name access appropriate with 6GT2002-0ED00?Use it only with the supported identification system and MOBY file-handler configuration. Direct-address and file-based access require the corresponding controller interface.
-
Which check prevents a replacement 6GT2002-0ED00 from reporting data for the wrong reading point?Verify each physical reader port against its controller assignment, then present a known target separately to each reading point.
-
How should communication recovery through 6GT2002-0ED00 be validated?Interrupt and restore the approved test path, observe diagnostics and verify that the application distinguishes fresh completed transactions from stale data.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studies-
Honeywell FC-RUSIO-3224 Delivered for an Oman Government ProjectRead case > -
28 ABB BRC410 Units: Ready to Inspect, Collected on Order DayRead case > -
GE IS420UCSBH4A: Confirm the Offered Controller and Release TermsRead case > -
24 Siemens Spare Parts Delivered to an Australian Waste Management FacilityRead case >
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.