6SL3000-0KH14-0AA0

DC-Link Precharge Resistor
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Siemens 6SL3000-0KH14-0AA0 is a 4.0-ohm precharging resistor for the specified 500–690 V SINAMICS S120 Basic Line Module arrangement.
  • Manufacturer part number
    6SL3000-0KH14-0AA0
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    22.5cm x 22cm x 22.5cm
  • Country of Origin
    Germany
Get a quick price for 6SL3000-0KH14-0AA0
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete Siemens 6SL3000-0KH14-0AA0 reference, label photographs and required quantity.

  • 1

    Confirm the offer

    Review the offered revision, condition, included items and documents against the confirmed installation.

  • 2

    Arrange dispatch

    Confirm quantity, dispatch date, lead-time start and delivery details in the quotation.

  • Match the complete marking

    Provide the complete Siemens 6SL3000-0KH14-0AA0 marking.

  • Check the offered item before ordering

    Request available label and connector photos. Have your maintenance team compare the offered 6SL3000-0KH14-0AA0 with the installed equipment and applicable Siemens instructions.

Technical specifications for 6SL3000-0KH14-0AA0

  • Manufacturer:
    Siemens
  • Product Category:
    PLC Systems
  • Spare Part Number:
    6SL3000 0KH14 0AA0
  • Weight:
    18.24 kg
  • Tariff Code:
    8537101190
  • Nominal resistance:
    4.0 Ω
  • Resistance tolerance:
    ±10%
  • Pulse-load energy:
    18000 W·s
  • Associated line-voltage range:
    500–690 V, three phase
  • Associated infeed architecture:
    Diode-based Basic Line Module, frame GD
  • Resistor quantity per phase:
    1, or 2 in parallel according to design
  • Total resistor quantity:
    3 or 6 for the specified three-phase circuit
  • Precharge-contactor control:
    Basic Line Module X9:5,6
  • Bypass-contactor control:
    Basic Line Module X9:3,4

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Siemens 6SL3000-0KH14-0AA0 limits DC-link charging current during the resistor-based precharge sequence before the main bypass path is closed.
Charging function: Limit current while the intended drive DC link is charged.
Sequence dependency: The precharge and bypass contactor paths operate at different stages.
Energy assessment: Component quantity and connection depend on the configured infeed and capacitance.
The resistor belongs to the charging path of the specified diode-based Basic Infeed arrangement. It limits the initial charging current before the bypass path is established.

Resistor quantity and phase connection depend on the engineered precharge circuit. The selected arrangement must match the DC-link capacitance and the associated infeed execution.

The precharge and bypass controls act in sequence. Successful component resistance checks do not by themselves establish that the complete charging circuit operates correctly.
Controller platform reference: Siemens SINAMICS S120 Basic Infeed. Match the installed configuration and applicable instructions.
Siemens 6SL3000-0KH14-0AA0: original manufacturer technical information covering the specified interfaces and operating limits. Installation topics include: identify the diode-based infeed, count the installed resistor paths, inspect the thermal condition, trace contactor sequence wiring, observe a controlled precharge.
Original manufacturer pages retain their technical context. Use the Apter Power guide with the applicable manufacturer instructions and approved installation design.
Prepare Siemens 6SL3000-0KH14-0AA0 for its configured installation using these checks.
Isolate line and DC-link energy

Follow the drive isolation and discharge procedure before touching the resistor or contactors. Verify the safe electrical state and account for every connected DC-link source and possible backfeed path.

Check resistance with the circuit isolated

Use the appropriate disconnected-component test method and compare the result with 4.0 ohms ±10%. Account for parallel paths before interpreting a measured resistance as the value of one resistor.

Review the capacitance budget

Compare the connected DC-link capacitance with the permitted arrangement for the Basic Line Module. Include changes to the drive line-up that may have occurred since the original precharge design was commissioned.

Restore protection and connections

Use the correct conductor, terminal and protective-device arrangement for the complete circuit. Inspect all phase paths and mechanical supports before energization, keeping the resistor pulse-energy limit distinct from continuous-load ratings.

Release the charging circuit

Record resistor values, quantity per phase, capacitance assessment and sequence-test results. Return the infeed to service only after the complete precharge and bypass arrangement operates as designed.

Observe a controlled precharge

Run the approved commissioning sequence and verify that the link charges before the bypass path takes over. Investigate abnormal timing, repeated retries or excessive heating before enabling normal drive operation.

Alternative Names

Siemens 6SL3000-0KH14-0AA0 6SL3000 0KH14 0AA0

Technical notes

Operating boundary: 18000 W·s is pulse energy, not a continuous-power claim.

Integration details: Match resistor quantity, DC-link capacitance and internally controlled contactor sequence.

FAQ View All FAQ

  • Why is the pulse-energy value of 6SL3000-0KH14-0AA0 not a continuous power rating?
    Energy is the integral of power over the charging event. It does not authorize a continuous load of the same numerical value; assess the actual precharge pulse and permitted operating sequence.
  • Can 6SL3000-0KH14-0AA0 be used as a braking resistor simply because both dissipate energy?
    No. It serves the specified precharge circuit. Braking duty has a different function and load profile, so resistance alone does not establish suitability.
  • How can parallel paths distort a resistance test on 6SL3000-0KH14-0AA0?
    A connected parallel resistor or circuit path changes the measured result. Use the approved isolated-component method before comparing the reading with the individual component tolerance.
  • Why must the bypass sequence be checked after replacing 6SL3000-0KH14-0AA0?
    The resistor limits charging current before the bypass takes over. Incorrect timing can defeat current limitation or leave the resistor carrying an unintended load.
  • What changes when a design uses two 6SL3000-0KH14-0AA0 resistors per phase?
    The effective resistance and energy distribution differ from a single-resistor path. Restore the specified quantity and connection in every phase rather than changing one branch in isolation.
  • How does a DC-link expansion affect 6SL3000-0KH14-0AA0 selection?
    Additional capacitance changes the charging requirement. Reassess the permitted Basic Infeed arrangement instead of assuming the existing resistor set remains suitable.
  • Why are repeated unsuccessful precharge attempts relevant to 6SL3000-0KH14-0AA0 diagnosis?
    Repeated charging events add thermal stress and can indicate an unresolved sequence or load problem. Investigate the underlying fault before repeatedly restarting the infeed.
  • Does a correct cold resistance prove that 6SL3000-0KH14-0AA0 will precharge the system correctly?
    No. Contactor operation, circuit connections and the connected capacitance still determine the event. Verify the complete approved charging sequence after the component check.