T8830

40-channel fused analog input field termination assembly for Trusted 8000 systems
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

ICS Triplex T8830 Trusted 40-Channel Analog Input Field Termination Assembly

Ask our team:

Get a quick price for: T8830
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for T8830

Technical specifications for T8830

  • Manufacturer:
    ICS Triplex
  • Product Category:
    DCS System
  • Spare Part Number:
    T8830
  • Estimated shipping dimensions:
    33.5x12.3x6.5cm
  • Weight:
    0.7 kg
  • Tariff Code:
    8537101101
  • Counliy of origin:
    USA
  • Product Type:
    Trusted 40-Channel Analog Input Field Termination Assembly
  • System Family:
    Trusted 8000
  • Channel / Interface Summary:
    40 analog input channels; 50 mA fuse and 250 Ω resistor per loop
  • Field supply:
    18–32 Vdc
  • Channels:
    40 analog inputs
  • Loop protection:
    50 mA fuse per channel
  • Conversion resistor:
    250 Ω per channel
  • FTA power dissipation:
    0.25 W
  • Official source:
    Rockwell Automation PD-T8830 Trusted 40 Channel Analog Input FTA
  • Signal / Data Handled:
    up to forty 0–22 mA field-current loops through individual 250 Ω conversion resistors
  • Compatible Components:
    T8431 analog input module, SmartSlot v1 cables, dual 24 Vdc field supplies and TS32/TS35 DIN rail
  • Lifecycle Reference:
    The official T8830 manual documents this assembly; confirm current lifecycle with Rockwell Automation.
  • Primary Application:
    SIS pressure transmitters
  • Secondary Application:
    Temperature transmitter loops
  • Verification Note:
    Confirm the exact T8830 physical nameplate and controlled project record.

Information

Information

Overview Manuals Common Applications Product Precautions
The T8830 is an ICS Triplex Trusted 40-Channel Analog Input Field Termination Assembly for Trusted 8000 systems.
  • 40 analog input channels; 50 mA fuse and 250 Ω resistor per loop
  • Designed for the Trusted 8000 architecture
  • terminates two-wire current loops, protects each loop and develops the measurement voltage used by the matched Trusted analog input module
  • Model-specific compatible hardware: T8431 analog input module, SmartSlot v1 cables, dual 24 Vdc field supplies and TS32/TS35 DIN rail

It terminates two-wire current loops, protects each loop and develops the measurement voltage used by the matched Trusted analog input module. It handles up to forty 0–22 mA field-current loops through individual 250 Ω conversion resistors and works with T8431 analog input module, SmartSlot v1 cables, dual 24 Vdc field supplies and TS32/TS35 DIN rail. For dependable operation, follow the official model-specific system matching, wiring, environmental and commissioning instructions.

Important Notice: Confirm the exact T8830 physical nameplate, hardware revision and controlled project record before installation or replacement.

Apter Power T8830 Manuals and Guides

Important Notice: These are two separate Apter Power documents with different layouts and model-specific content, prepared from the manufacturer-published source identified in each document. Confirm the physical nameplate, current Rockwell Automation documentation, and host-system requirements before installation or replacement.

SIS pressure transmitters
T8830 terminates two-wire current loops, protects each loop and develops the measurement voltage used by the matched Trusted analog input module.
Temperature transmitter loops
T8830 up to forty 0–22 mA field-current loops through individual 250 Ω conversion resistors.
Fire and gas analog detectors
T8830 terminates two-wire current loops, protects each loop and develops the measurement voltage used by the matched Trusted analog input module.
Level and flow trip inputs
T8830 up to forty 0–22 mA field-current loops through individual 250 Ω conversion resistors.
Forty-loop analog marshalling
T8830 terminates two-wire current loops, protects each loop and develops the measurement voltage used by the matched Trusted analog input module.
Read Rockwell Automation PD-T8830 Trusted 40 Channel Analog Input FTA and the applicable system installation instructions before use. Verify the exact model, revision, slot or base, termination hardware and field wiring.
1
Match T8830 to the approved T8431 analog input channel arrangement and SmartSlot cables.
2
Verify the dual 24 Vdc field supplies, loop polarity and transmitter power scheme.
3
Keep analog loop shields and grounding consistent with the controlled cabinet drawing.
4
Replace a channel fuse only after locating the loop fault and confirming the specified fuse.
5
Validate zero, span, open-loop response and diagnostics for every commissioned channel.

Alternative Names

Alternative Names

T8830 ICS Triplex ICS Triplex T8830 Trusted 8000 T8830

Technical notes

Technical notes

Official source: Rockwell Automation PD-T8830 Trusted 40 Channel Analog Input FTA. Confirm the exact physical nameplate and current Rockwell Automation record before replacement.

FAQS

  • What is the ICS Triplex T8830?
    It is a Trusted 40-Channel Analog Input Field Termination Assembly for Trusted 8000 control and safety architectures.
  • What does T8830 do?
    terminates two-wire current loops, protects each loop and develops the measurement voltage used by the matched Trusted analog input module.
  • What signals or data does it handle?
    up to forty 0–22 mA field-current loops through individual 250 Ω conversion resistors.
  • Which components are compatible?
    T8431 analog input module, SmartSlot v1 cables, dual 24 Vdc field supplies and TS32/TS35 DIN rail.
  • Where is this model applied?
    SIS pressure transmitters, Temperature transmitter loops, Fire and gas analog detectors, Level and flow trip inputs, Forty-loop analog marshalling.
  • What should be checked before replacement?
    Confirm the complete model, physical nameplate, hardware revision, slot or base, termination hardware, field wiring, configuration and current official documentation.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.