Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for T8830
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for T8830

  • Manufacturer:
    ICS Triplex
  • Product Category:
    DCS Systems
  • Spare Part Number:
    T8830
  • Estimated shipping dimensions:
    33.5x12.3x6.5cm
  • Weight:
    0.7 kg
  • Tariff Code:
    8537101101
  • Counliy of origin:
    USA
  • Product Type:
    Trusted 40-Channel Analog Input Field Termination Assembly
  • System Family:
    Trusted 8000
  • Channel / Interface Summary:
    40 analog input channels; 50 mA fuse and 250 Ω resistor per loop
  • Field supply:
    18–32 Vdc
  • Channels:
    40 analog inputs
  • Loop protection:
    50 mA fuse per channel
  • Conversion resistor:
    250 Ω per channel
  • FTA power dissipation:
    0.25 W
  • Official source:
    Rockwell Automation PD-T8830 Trusted 40 Channel Analog Input FTA
  • Signal / Data Handled:
    up to forty 0–22 mA field-current loops through individual 250 Ω conversion resistors
  • Compatible Components:
    T8431 analog input module, SmartSlot v1 cables, dual 24 Vdc field supplies and TS32/TS35 DIN rail
  • Lifecycle Reference:
    The official T8830 manual documents this assembly; confirm current lifecycle with Rockwell Automation.
  • Primary Application:
    SIS pressure transmitters
  • Secondary Application:
    Temperature transmitter loops
  • Verification Note:
    Confirm the exact T8830 physical nameplate and controlled project record.

Information

Overview Manuals Common Applications Product Precautions
The T8830 is an ICS Triplex Trusted 40-Channel Analog Input Field Termination Assembly for Trusted 8000 systems.
  • 40 analog input channels; 50 mA fuse and 250 Ω resistor per loop
  • Designed for the Trusted 8000 architecture
  • terminates two-wire current loops, protects each loop and develops the measurement voltage used by the matched Trusted analog input module
  • Model-specific compatible hardware: T8431 analog input module, SmartSlot v1 cables, dual 24 Vdc field supplies and TS32/TS35 DIN rail

It terminates two-wire current loops, protects each loop and develops the measurement voltage used by the matched Trusted analog input module. It handles up to forty 0–22 mA field-current loops through individual 250 Ω conversion resistors and works with T8431 analog input module, SmartSlot v1 cables, dual 24 Vdc field supplies and TS32/TS35 DIN rail. For dependable operation, follow the official model-specific system matching, wiring, environmental and commissioning instructions.

Important Notice: Confirm the exact T8830 physical nameplate, hardware revision and controlled project record before installation or replacement.

Apter Power T8830 Manuals and Guides

Important Notice: These are two separate Apter Power documents with different layouts and model-specific content, prepared from the manufacturer-published source identified in each document. Confirm the physical nameplate, current Rockwell Automation documentation, and host-system requirements before installation or replacement.

SIS pressure transmitters
T8830 terminates two-wire current loops, protects each loop and develops the measurement voltage used by the matched Trusted analog input module.
Temperature transmitter loops
T8830 up to forty 0–22 mA field-current loops through individual 250 Ω conversion resistors.
Fire and gas analog detectors
T8830 terminates two-wire current loops, protects each loop and develops the measurement voltage used by the matched Trusted analog input module.
Level and flow trip inputs
T8830 up to forty 0–22 mA field-current loops through individual 250 Ω conversion resistors.
Forty-loop analog marshalling
T8830 terminates two-wire current loops, protects each loop and develops the measurement voltage used by the matched Trusted analog input module.
Read Rockwell Automation PD-T8830 Trusted 40 Channel Analog Input FTA and the applicable system installation instructions before use. Verify the exact model, revision, slot or base, termination hardware and field wiring.
1
Match T8830 to the approved T8431 analog input channel arrangement and SmartSlot cables.
2
Verify the dual 24 Vdc field supplies, loop polarity and transmitter power scheme.
3
Keep analog loop shields and grounding consistent with the controlled cabinet drawing.
4
Replace a channel fuse only after locating the loop fault and confirming the specified fuse.
5
Validate zero, span, open-loop response and diagnostics for every commissioned channel.

Alternative Names

T8830 ICS Triplex ICS Triplex T8830 Trusted 8000 T8830

Technical notes

Official source: Rockwell Automation PD-T8830 Trusted 40 Channel Analog Input FTA. Confirm the exact physical nameplate and current Rockwell Automation record before replacement.

FAQ View All FAQ

  • What is the ICS Triplex T8830?
    It is a Trusted 40-Channel Analog Input Field Termination Assembly for Trusted 8000 control and safety architectures.
  • What does T8830 do?
    terminates two-wire current loops, protects each loop and develops the measurement voltage used by the matched Trusted analog input module.
  • What signals or data does it handle?
    up to forty 0–22 mA field-current loops through individual 250 Ω conversion resistors.
  • Which components are compatible?
    T8431 analog input module, SmartSlot v1 cables, dual 24 Vdc field supplies and TS32/TS35 DIN rail.
  • Where is this model applied?
    SIS pressure transmitters, Temperature transmitter loops, Fire and gas analog detectors, Level and flow trip inputs, Forty-loop analog marshalling.
  • What should be checked before replacement?
    Confirm the complete model, physical nameplate, hardware revision, slot or base, termination hardware, field wiring, configuration and current official documentation.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.