The T8310 is an ICS Triplex Trusted Expander Processor for the Trusted 8000 system.
- Trusted Expander Processor
- Trusted expander-bus control, status and I/O data
- Coordinates controller and expansion chassis traffic
- 266 x 31 x 303 mm
It manages the Trusted expander bus and coordinates data transfer between controller and expansion chassis. It handles Trusted expander-bus control, status and I/O data and operates with Trusted controller chassis, expander interfaces, approved expander cables and configured expansion chassis. Verify the exact hardware revision, matched termination and controlled application records before commissioning.
Important Notice: Use the complete T8310 code and verify the physical nameplate, current ICS Triplex / Rockwell Automation documentation, field wiring, project, and compatible system hardware before installation or replacement.
Apter Power T8310 Manuals and Guides
Important Notice: These are two separate Apter Power documents prepared from the manufacturer-published ICS Triplex / Rockwell Automation information named in each document. Confirm the physical nameplate, current ICS Triplex / Rockwell Automation documents, and host-system requirements before installation or replacement.
Large Trusted SIS cabinets
Uses the T8310 trusted expander processor in a model-appropriate Trusted 8000 control or protection function.
Distributed chassis expansion
Handles system status and diagnostics under the official engineering limits.
High-I/O-count shutdown systems
Uses the T8310 trusted expander processor in a model-appropriate Trusted 8000 control or protection function.
Redundant controller architectures
Handles system status and diagnostics under the official engineering limits.
Read Rockwell Automation ICSTT-RM266N-EN-P and the applicable system installation instructions before use. Verify the physical nameplate, revision, slot and matched termination hardware.
1
Verify the exact model, hardware revision, firmware and nameplate before substitution.
2
Install only with Trusted controller chassis, expander interfaces, approved expander cables and configured expansion chassis; do not mix unmatched termination or base hardware.
3
De-energize or follow the approved live-insertion procedure and site safety plan before removal.
4
Preserve module keying, slot assignment, wiring polarity, shields, grounding and field power limits.
5
Complete application download, diagnostics, proof testing and functional acceptance before return to service.